MIRELLA ESMANHOTTO FACIN SAMESIMA

(Fonte: Lattes)
Índice h a partir de 2011
5
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina - Médico
LIM/65, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 4 de 4
  • article 2 Citação(ões) na Scopus
    Contribution of the vectorcardiogram in the differential diagnosis of Brugada electrocardiographic pattern
    (2022) MADALOSO, Bruna A.; SAMESIMA, Nelson; TOBIAS, Nancy M. M. O.; TAVARES, Caio A. M.; FILHO, Horacio G. Pereira; FACIN, Mirella E.; PASTORE, C. A.
    Background: The electrocardiogram (ECG) is a powerful tool for differential diagnosis among a group of pathologies with different therapeutic approaches/prognoses, the so-called J-wave syndrome. The vectorcardiogram (VCG) can be used as a complementary method to the ECG in several dubious electrocardiographic alterations. Objective: We carried out a VCG analysis alter conceiving and measuring a novel parameter (JT-distance) that allows diagnosis of the Brugada ECG pattern. Methods: A retrospective cohort study selected ninety-six ECGs with J-point elevation in V-1/V-2, ECG superior leads and VCGs, all performed on the same day. A new VCG measurement by Frank method (IT-distance) was conceived and designed in transverse and right sagittal planes by 3 lines drawn 1) at the final third of the QRS loop, comprehending the J-point; 2) at the initial portion of the T loop; 3) a parallel of the J-point line at the beginning of the T loop. JT measure was determined by the distance between parallels. A validation cohort was established in a new sample of thirty-five patients. Results: JT-distance >= 1.5 mm (tranverse plane) and JT-distance >1.25 mm, in the sagittal plane, differentiated Brugada type-1 from Brugada type-2, early repolarization and others, with 95% sensitivity and 68% specificity. JT-distance <1.5 mm (transverse plane) and JT >1.25 mm (sagittal plane) had 100% sensitivity and 85% specificity for Brugada type-1 diagnosis. A validation cohort showed very similar Cohen's kappa levels (0.65 and 0.77, test and validation cohorts, respectively), with overlapping 95% confidence intervals. Conclusions: The novel vectorcardiogram measurement (JT-distance) presented a new diagnostic criterion to identify Brugada pattern. Nevertheless, prospective studies should be performed by other centers to confirm these findings.
  • article 13 Citação(ões) na Scopus
    Brazilian Society of Cardiology Guidelines on the Analysis and Issuance of Electrocardiographic Reports-2022
    (2022) SAMESIMA, Nelson; GOD, Epotamenides Good; KRUSE, Jose Claudio Lupi; LEAL, Marcelo Garcia; PINHO, Claudio; FRANCA, Francisco Faustino de A. C.; PIMENTA, Joao; CARDOSO, Acacio Fernandes; PAIXAO, Adail; FONSECA, Alfredo; PEREZ-RIERA, Andres R.; RIBEIRO, Antonio Luiz Pinho; MADALOSO, Bruna Affonso; LUNA FILHO, Braulio; OLIVEIRA, Carlos Alberto Rodrigues de; GRUPI, Cesar Jose; MOREIRA, Dalmo Antonio Ribeiro; KAISER, Elisabeth; PAIXAO, Gabriela Miana de Mattos; FEITOSA FILHO, Gilson; PEREIRA FILHO, Horacio Gomes; GRINDLER, Jose; AZIZ, Jose Luiz; MOLINA, Marcos Sleiman; FACIN, Mirella; TOBIAS, Nancy M. M. de Oliveira; OLIVEIRA, Patricia Alves de; SANCHES, Paulo Cesar R.; TEIXEIRA, Ricardo Alkmin; ATANES, Severiano Melo; PASTORE, Carlos Alberto
  • article 13 Citação(ões) na Scopus
    Applicability of the Electro-Vectorcardiogram in Current Clinical Practice
    (2019) PASTORE, Carlos Alberto; SAMESIMA, Nelson; PEREIRA FILHO, Horacio Gomes; TOBIAS, Nancy Maria Martins de Oliveira; MADALOSO, Bruna Affonso; FACIN, Mirella Esmanhotto
    The electrocardiogram (ECG) has been reinvigorated by the identification of electrical alterations that were not definitely clarified before. In this context, and mainly regarding the definition of arrhythmogenic substrates, the association of the ECG with the vectorcardiogram (VCG) has gathered much more information about the cardiac electrical phenomena, thus allowing us to differentiate potentially fatal cases from benign ones. Obtaining a VCG concomitantly with the performance of an ECG has led to a significant gain in the definition of extremely sophisticated pathologies, which function suffer some type of structural or dynamic alterations, involving either the reduction or enhancement of ionic channels and currents. The classic aspects of the ECG/VCG association in the differential diagnosis of myocardial infarctions, conduction disorders, atrial and ventricular hypertrophies, and the correlations between these electrical disorders are still valid and assertive. The association of these pathologies is further clarified when they are seen through the ECG/VCG dyad. The three-dimensional spatial orientation of both the atrial and the ventricular activity provides a far more complete observation tool than the ECG linear form. The modern analysis of the ECG and its respective VCG, simultaneously obtained by the recent technique called electro-vectorcardiogram (ECG/VCG), brought a significant gain for the differential diagnosis of some pathologies. Therefore, we illustrate how this type of analysis can elucidate some of the most important diagnoses found in our daily clinical practice as cardiologists.
  • article 0 Citação(ões) na Scopus
    Modified moving average methodology applied to the treadmill stress testing analysis of microvolt T-wave alternans
    (2022) PEREIRA FILHO, Horacio Gomes; SAMESIMA, Nelson; MADALOSO, Bruna Affonso; TOBIAS, Nancy Maria Martins de Oliveira; FACIN, Mirella; PASTORE, Carlos Alberto
    Sudden cardiac death is impactful. There has been an increase in the search for tools capable of identifying individuals who are most susceptible, such as the microvolt T-wave alternans. This study aims to analyze the applicability of the modified moving average methodology to obtain the microvolt T-wave alternans using treadmill specific protocols. Medical records of patients during the period August 2006-December 2014 were retrospectively analyzed. Five hundred and thirty nine exams were then included, divided into groups according to the protocol and updating factor used: Ellestad factor 8 or 32, Naughton factor 8 or 32. The topics for analysis were the alternans behavior, noise and confirmation according to the groups of leads analyzed (frontal, transversal and orthogonal planes). The greater microvolt T-wave alternans was found during the stress phase in most of the tests. Group Naughton 8 presented lower noise in this phase for the transverse and orthogonal planes (p=0.0082 and p<0.0001), with greater confirmation of frontal and orthogonal planes in comparison with group Ellestad 8 (p=0.0002 and 0.0008). The results indicate the viability of simultaneous performance of the stress test and measurement of the T wave alternans with Naughton protocol with 1/8 updating factor.