TANIELA MARLI BES

(Fonte: Lattes)
Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais
LIM/49 - Laboratório de Protozoologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 4 de 4
  • article 0 Citação(ões) na Scopus
    Conjugative transfer of plasmid p_8N_qac(MN687830.1) carrying qacA gene from Staphylococcus aureus to Escherichia coli C600: potential mechanism for spreading chlorhexidine resistance
    (2021) BES, Taniela Marli; NAGANO, Debora Satie; MARCHI, Ana Paula; CAMILO, Gaspar; PERDIGAO-NETO, Lauro Vieira; MARTINS, Roberta Ruedas; LEVIN, Anna Sara; COSTA, Silvia Figueiredo
    The methicillin resistant Staphylococcus aureus (MRSA) is recognized by its ability to acquire and transferring resistance genes through interspecies conjugative plasmids. However, transference of plasmids from Gram-positive cocci to Gram-negative bacilli is not well characterized. In this report, we describe the transfer of a conjugative plasmid carrying qacA from MRSA to Escherichia coli C600. We performed a conjugation experiment using a chlorhexidine resistant MRSA isolate (ST-105/SCCmec type III) carrying the gene qacA and qacC as the donor and a chlorhexidine susceptible E. coli C600 isolate as the receptor. Transconjugants were selected using MacConkey agar plates containing chlorhexidine in concentrations ranging from 0.25 to 16 g.L-1. To genotypically confirm the transfer of the resistance gene, the transconjugants were screened by Polymerase Chain Reaction (PCR) and submitted to Sanger's sequencing. MRSA isolates successfully transferred the chlorhexidine resistance gene (qacA) to the recipient E. coli strain C600. The E. coli transconjugant exhibited an important reduction of chlorhexidine susceptibility, with MICs increasing from <= 0.25 to >= 16 g.L-1 after conjugation. The qacA gene was detected by PCR as well as in the Sanger's sequencing analysis of DNA from transconjugant plasmids. To the best of our knowledge, this is the first report of the plasmid p_8N_qac(MN687830.1) carrying qacA and its transfer by conjugation from a MRSA to an E. coli. These findings increase concerns on the emergence of resistance dissemination across the genus and emphasizes the importance of continuous antiseptic stewardship.
  • article 9 Citação(ões) na Scopus
    Prevalence of methicillin-resistant Staphylococcus aureus colonization in individuals from the community in the city of Sao Paulo, Brazil
    (2018) BES, Taniela Marli; MARTINS, Roberta Ruedas; PERDIGAO, Lauro; MONGELOS, Diego; MORENO, Luisa; MORENO, Andrea; OLIVEIRA, Gerson Salvador de; COSTA, Silvia Figueiredo; LEVIN, Anna Sara
    Staphylococcus aureus (SA) is a commensal habitant of nasal cavities and skin. Colonization by community-acquired methicillin-resistant SA (CA-MRSA) is associated with infections in patients who have not been recently hospitalized. The aim of this study is to determine the prevalence of MRSA colonization in an outpatient population, currently unknown in Brazil. Three-hundred patients or caregivers from two teaching hospitals were included. A questionnaire was applied and nasal swabs were obtained from patients. Swabs were inoculated in brain heart infusion (BHI) with 25% NaCl and seeded in mannitol. Suspicious colonies were subjected to MALDI-TOF MS Microflex (TM) identification. Antimicrobial susceptibility test for oxacillin was performed for SA-positive samples by microdilution. Polymerase chain-reactions for detection of mecA and coA genes were performed for resistant samples. Data about MRSA carriers were compared with non-carriers. There were 127 S. aureus isolates, confirmed by MALDI-TOF. Only seven (2.3%) were MRSA and positive for mecA and coA genes. Factors associated with MRSA carriage were African ethnicity, skin diseases or antibiotic use. The majority of them were from Dermatology clinics. Prevalence of MRSA colonization in individuals from the community was low in our study (2.3%). This finding raises the hypothesis of inter-household transmission of SA. although we did not find any association between MRSA-colonization and the shared use of personal objects. Given the low prevalence of MRSA carriers observed, empirical antimicrobial coverage for MRSA in community-acquired infections should be not necessary.
  • article 4 Citação(ões) na Scopus
    Deriving a parsimonious cardiac endpoint for use in epidemiological studies of Chagas disease: results from the Retrovirus Epidemiology Donor Study-II (REDS-II) cohort
    (2021) BUSS, Lewis F.; BES, Taniela Marli; PEREIRA, Alexandre; NATANY, Larissa; OLIVEIRA, Claudia Di Lorenzo; RIBEIRO, Antonio Luiz P.; SABINO, Ester Cerdeira
    Chagas cardiomyopathy (ChCM) is a severe consequence of Trypanosoma cruzi infection and has a range of electrocardiographic (ECG) and echocardiographic (ECHO) manifestations. There is a need for a standard and parsimonious research cardiac end point that does not rely on expert panel adjudication, and it is not intended to change the ChCM definition. We use data from the REDS-II cohort to propose a simplified cardiac endpoint. A total of 499 T. cruzi-seropositive blood donors were included. All participants underwent a 12-lead ECG, echocardiogram and clinical examination, and those with abnormal findings were reviewed by a panel of cardiologists who classified cases as having Chagas cardiomyopathy or not. We created an exhaustive set of ECG and ECHO finding combinations and compared these with the panel's classification. We selected the simplest combination that most accurately reproduced the panel's results. Individual ECG and ECHO variables had low sensitivity for panel-defined cardiomyopathy. The best performing combination was right bundle branch block and/or ECHO evidence of left ventricular hypocontractility. This combination had 98% specificity and 85% sensitivity for panel-defined ChCM. It was not possible to improve the overall accuracy by addition of any other ECG or ECHO variable. Substituting right bundle branch block for the more inclusive finding of QRS interval > 120 ms produced similar results. The combination of prolonged QRS interval and/or left ventricular hypocontractility closely reproduced the REDS-II expert panel classification of Chagas ChCM. In conclusion, the simple and reproducible research endpoint proposed here captures most of the spectrum of cardiac abnormalities in Chagas disease.
  • article 4 Citação(ões) na Scopus
    Susceptibility to chlorhexidine and mupirocin among methicillin-resistant Staphylococcus aureus clinical isolates from a teaching hospital
    (2021) BES, Taniela Marli; PERDIGAO-NETO, Lauro; MARTINS, Roberta Ruedas; HEIJDEN, Inneke; TRINDADE, Priscila de Arruda; CAMILO, Gaspar; NAGANO, Debora Satie; MONGELOS, Diego; MARCHI, Ana Paula; TOMAZ, Mariama; OLIVEIRA, Larissa Marques de; ROSSI, Flavia; LEVIN, Anna Sara; COSTA, Silvia Figueiredo
    Despite the widespread use of chlorhexidine (CHX) to prevent infection, data regarding the in vitro action of CHX against methicillin-resistant Staphylococcus aureus (MRSA) are limited. Clinical isolates from Hospital das Clinicas, Sao Paulo, Brazil, identified during 2002/2013 and 2012/2013 were studied to describe the susceptibility to CHX and mupirocin, molecular characteristics, and virulence profile of MRSA. Susceptibility test to Mupirocin was performed by the disk diffusion method and to CHX by the agar dilution technique. PCR for virulence genes, mecA gene and Staphylococcal Cassette Chromosome mec (SCCmec) types were investigated as well. Mupirocin- and CHX-resistant isolates were sequenced using the Illumina (TM) plataform. Two hundred and sixteen MRSA clinical isolates were evaluated: 154 from infected and 62 from colonized patients. Resistance to mupirocin was observed in four isolates assigned as SCOnec type III and STs (ST05; ST239 and ST105) carrying mupA and blaZ, two of them co-harboring the ileS gene. Only one isolate assigned as SCCmec type III was resistant to CHX (MIC of 8.0 mu g.mL(-1)) and harbored the qacA gene. Resistance to chlorhexidine and mupirocin were found in isolates carrying qacA and mupA in our hospital. Since these genes are plasmid-mediated, this finding draws attention to the potential spread of resistance to mupirocin in our hospital.