ADILSON COSTA RODRIGUES JUNIOR

(Fonte: Lattes)
Índice h a partir de 2011
2
Projetos de Pesquisa
Unidades Organizacionais
LIM/62 - Laboratório de Fisiopatologia Cirúrgica, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • article 0 Citação(ões) na Scopus
    Continuous peritoneal lavage with vacuum perito-neostomy: an experimental study
    (2019) RODRIGUES, Adilson Costa; SAAD, Karen Ruggeri; SAAD, Paulo Fernandes; OTSUKI, Denise Aya; SANTOS, Luana Carla dos; RASSLAN, Samir; MONTERO, Edna Frasson de Souza; UTIYAMA, Edivaldo M.
    OBJECTIVE: Despite advances in diffuse peritonitis treatment protocols, some cases develop unfavorably. With the advent of vacuum therapy, the use of laparostomy to treat peritonitis has gained traction. Another treatment modality is continuous peritoneal lavage. However, maintaining this technique is difficult and has been associated with controversial results. We propose a new model of continuous peritoneal lavage that takes advantage of the features and benefits of vacuum laparostomy. METHOD: Pigs (Landrace and Large White) under general anesthesia were submitted to laparostomy through which a multiperforated tube was placed along each flank and exteriorized in the left and lower right quadrants. A vacuum dressing was applied, and intermittent negative pressure was maintained. Peritoneal dialysis solution (PDS) was then infused through the tubes for 36 hours. The stability of peritoneostomy with intermittent infusion of fluids, the system resistance to obstruction and leakage, water balance, hemodynamic and biochemical parameters were evaluated. Fluid disposition in the abdominal cavity was analyzed through CT. RESULTS: Even when negative pressure was not applied, the dressing maintained the integrity of the system, and there were no leaks or blockage of the catheters during the procedure. The aspirated volume by vacuum laparostomy was similar to the infused volume (9073.5 +/- 1496.35 mL versus 10165 +/- 235.73 mL, p=0.25), and there were no major changes in hemodynamic or biochemical analysis. According to CT images, 60 ml/kg PDS was sufficient to occupy all intra-abdominal spaces. CONCLUSION: Continuous peritoneal lavage with negative pressure proved to be technically possible and may be an option in the treatment of diffuse peritonitis.
  • article 2 Citação(ões) na Scopus
    Animal model of continuous peritoneal lavage with vacuum peritoneostomy
    (2017) RODRIGUES, Adilson Costa; SANTOS, Luana Carla Dos; OTSUKI, Denise Aya; SAAD, Karen Ruggeri; SAAD, Paulo Fernandes; MONTERO, Edna Frasson de Souza; UTIYAMA, Edivaldo Massazo
    Purpose: To establish and evaluate the feasibility of continuous peritoneal lavage with vacuum peritoneostomy in an animal model. Methods: Eight pigs aged 3-4 months, females, were anesthetized and submitted to laparotomy and installation of a continuous peritoneal lavage with vacuum peritoneostomy. The sta-bility of the system, the physiological effects of washing with NaCl 0.9% and the sys-tem clearance were evaluated. Results: Stability of vacuum peritoneostomy was observed, with no catheter leaks or obstructions and the clearance proved adequate, however, the mean volume of fluids aspirated by the peritoneostomy at the end of the experiment was higher than the volume infused by the catheters (p=0.02). Besides that, the animals presented a progressive increase in heart rate (p=0.04) and serum potassium (p=0.02). Conclusion: The continuous peritoneal lavage technique with vacuum peritoneostomy is feasible and presents adequate clearance.