CHILAN BOU GHOSSON LEITE

(Fonte: Lattes)
Índice h a partir de 2011
5
Projetos de Pesquisa
Unidades Organizacionais
LIM/05 - Laboratório de Poluição Atmosférica Experimental, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 10 de 11
  • article 8 Citação(ões) na Scopus
    BIOLOGICAL ENHANCEMENTS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION
    (2019) LEITE, Chilan Bou Ghosson; DEMANGE, Marco Kawamura
    The anterior cruciate ligament (ACL) is mostly responsible for providing knee stability. ACL injury has a marked effect on daily activities, causing pain, dysfunction, and elevated healthcare costs. ACL reconstruction (ACLR) is the standard treatment for this injury. However, despite good results, ACLR is associated with a significant rate of failure. In this context, the mechanical and biological causes must be considered. From a biological perspective, the ACLR depends on the osseointegrati on of the graft in the adjacent bone and the process of intra-articular ligamentization for good results. Here, we discuss the mechanisms underlying the normal graft healing process after ACLR and its biological modulation, thus, presenting novel strategies for biological enhancements of the ACL graft.
  • article 4 Citação(ões) na Scopus
    Performance of alpha-defensin lateral flow test after synovial fluid centrifugation for diagnosis of periprosthetic knee infection
    (2021) ABDO, Rodrigo Calil Teles; GOBBI, Riccardo Gomes; LEITE, Chilan Bou Ghosson; PASOTO, Sandra Gofinet; LEON, Elaine Pires; LIMA, Ana Lucia Lei Munhoz; BONFA, Eloisa; PECORA, Jose Ricardo; DEMANGE, Marco Kawamura
    BACKGROUND The quantitative alpha-defensin enzyme-linked immunosorbent assay (ELISA) demands a prior synovial fluid centrifugation, whereas this processing is not routinely required prior to the alpha-defensin lateral flow test. AIM To evaluate whether a prior synovial fluid centrifugation could lead the lateral flow performance to achieve comparable results to ELISA during periprosthetic joint infection (PJI) diagnosis. METHODS Fifty-three cases were included in this study: 22 classified as PJI and 31 classified as aseptic cases, according to Musculoskeletal Infection Society 2013 criteria. Synovial fluid samples were submitted to centrifugation, and the supernatant was evaluated by ELISA and lateral flow tests. The sensitivity (SE), specificity (SP) and accuracy of each method were calculated as well as the agreement between those two methods. RESULTS In all of the 31 samples from aseptic patients, alpha-defensin ELISA and lateral flow tests showed negative results for infection. Regarding the 22 infected patients, the lateral flow test was positive in 19 cases (86.4%) and the ELISA was positive in 21 (95.5%). Sensibility, SP and accuracy were, respectively, 86.4% (95%CI: 65.1%-97.1%), 100% (95%CI: 88.8%-100%) and 93.2% (95%CI: 82.8%-98.3%) for the lateral flow test and 95.5% (95%CI: 77.2%-99.9%), 100% (95%CI: 88.8%-100%) and 98.1% (95%CI: 89.9%-100%) for ELISA. An agreement of 96.2% between those methods were observed. No statistical difference was found between them (P = 0.48). CONCLUSION Alpha-defensin lateral flow test showed high SE, SP and accuracy after a prior synovial fluid centrifugation, achieving comparable results to ELISA. Considering the lower complexity of the lateral flow and its equivalent performance obtained in this condition, a prior centrifugation might be added as a valuable step to enhance the PJI diagnosis.
  • article 3 Citação(ões) na Scopus
    Revisiting the role of hyperbaric oxygen therapy in knee injuries: Potential benefits and mechanisms
    (2023) LEITE, Chilan B. G.; TAVARES, Luciana P. P.; LEITE, Magno S. S.; DEMANGE, Marco K. K.
    Knee injury negatively impacts routine activities and quality of life of millions of people every year. Disruption of tendons, ligaments, and articular cartilage are major causes of knee lesions, leading to social and economic losses. Besides the attempts for an optimal recovery of knee function after surgery, the joint healing process is not always adequate given the nature of intra-articular environment. Based on that, different therapeutic methods attempt to improve healing capacity. Hyperbaric oxygen therapy (HBOT) is an innovative biophysical approach that can be used as an adjuvant treatment post-knee surgery, to potentially prevent chronic disorders that commonly follows knee injuries. Given the well-recognized role of HBOT in improving wound healing, further research is necessary to clarify the benefits of HBOT in damaged musculoskeletal tissues, especially knee disorders. Here, we review important mechanisms of action for HBOT-induced healing including the induction of angiogenesis, modulation of inflammation and extracellular matrix components, and activation of parenchyma cells-key events to restore knee function after injury. This review discusses the basic science of the healing process in knee injuries, the role of oxygen during cicatrization, and shed light on the promising actions of HBOT in treating knee disorders, such as tendon, ligament, and cartilage injuries.
  • article 2 Citação(ões) na Scopus
    The knee in congenital femoral deficiency and its implication in limb lengthening: a systematic review
    (2021) LEITE, Chilan Bou Ghosson; GRANGEIRO, Patricia Moreno; MUNHOZ, Diego Ubrig; GIGLIO, Pedro Nogueira; CAMANHO, Gilberto Luis; GOBBI, Riccardo Gomes
    Congenital femoral deficiency (CFD) is a rare disorder with several limb anomalies including limb shortening and knee cruciate ligament dysplasia. Limb lengthening is usually performed to correct lower limb discrepancy. However, complications, such as knee subluxation/dislocation, can occur during this treatment. Here, we explore CFD knee abnormalities and knee dislocation during limb elongation, discussing when and whether knee ligament reconstruction prior to the lengthening would be necessary to reduce the risk of knee dislocation. There is not enough support in the literature for the routine reconstruction of cruciate ligaments in CFD patients. Of note, in cases of severe anteroposterior or posterolateral rotatory instability, cruciate ligament reconstruction might be considered to decrease the risk of knee subluxation/dislocation during the lengthening treatment.
  • article 27 Citação(ões) na Scopus
    Tibial Tubercle Osteotomy With Distalization Is a Safe and Effective Procedure for Patients With Patella Alta and Patellar Instability
    (2021) LEITE, Chilan B. G.; SANTOS, Tarsis P.; GIGLIO, Pedro N.; PECORA, Jose R.; CAMANHO, Gilberto L.; GOBBI, Riccardo G.
    Background: Tibial tubercle osteotomy with concomitant distalization for the treatment of patellar instability remains controversial, as it may cause anterior knee pain and chondral degeneration. Purpose: To evaluate radiographic, clinical, and functional outcomes in patients who had patellar instability with patella alta and underwent tibial tubercle osteotomy with distalization (TTO-d) as well as medial patellofemoral ligament reconstruction. Study Design: Case series; Level of evidence, 4. Methods: Included in this study were 25 patients (31 cases) (mean age at surgery, 28.7 years; range, 14-33 years) with patellar instability and patella alta who underwent TTO-d with minimum 1-year follow-up. The Caton-Deschamps index (CDI), tibial tubercle-trochlear groove (TT-TG) distance, and amount of distalization were assessed. Clinical and functional variables included J-sign, anterior knee pain, apprehension test, Tegner activity level, and Kujala score. Results: The mean follow-up period was 2.62 years. The mean TT-TG was 16.15 mm (range, 7-24 mm); the mean CDI changed from 1.37 (1.25-1.7) preoperatively to 1.02 (0.9-1.12) postoperatively (P = .001); and the mean amount of tibial tubercle distalization was 8.80 mm (range, 4-16 mm). Lateral release (22 cases; 71.0%), medialization of tibial tubercle (17 cases; 54.8%), and autologous chondrocyte implantation (4 cases; 12.9%) were other associated procedures. The J-sign improved in 30 cases (96.8%; P = .001), and there was a complete resolution of anterior knee pain in 22 cases (71.0%; P = .001). An exploratory analysis showed that patellar cartilage defect severity was correlated with persistent pain (P = .005). The apprehension test became negative in all cases (P = .001). The median Kujala score increased from 52 to 77 (P = .001), and the median Tegner activity level improved from 3 to 4 (P = .001). No cases of osteotomy nonunion were reported. One case (3.2%) of patellar instability recurrence and 3 cases (6.5%) with painful hardware were observed. Conclusion: TTO-d resulted in good radiographic, clinical, and functional outcomes providing proper patellar stability to patients with patella alta. TTO-d appears to be a safe and efficient procedure with low complication rates, providing an additional tool for the personalized treatment of patellar instability.
  • article 1 Citação(ões) na Scopus
    Harvest Technique Does Affect the Quality of Osteochondral Grafts: Histologic Evaluation Comparing Commercial Standards versus Scalpel Blade Technique
    (2023) MERKELY, Gergo; LEITE, Chilan B. G.; FARINA, Evan M.; GOMOLL, Andreas H.; LATTERMANN, Christian
    Objective While the percentage of viable cells is a major determinant of graft performance during osteochondral allograft (OCA) transplantation, the baseline chondrocyte viability at the periphery of osteochondral plugs is defined at the time of harvest. In this laboratory study, we aimed to determine the optimal technique for OCA plug harvest by evaluating commercial standard techniques compared to sharp blade harvest technique. Design Osteochondral explants were harvested from bovine and human samples using 3 different techniques: (1) standard OATS manual punch device (Osteochondral Autograft Transplant System OATS; Arthrex, Naples, FL), (2) powered trephine device, and (3) fresh scalpel blade. Chondrocyte viability and the dead area at the periphery of the tissue were evaluated by LIVE/DEAD staining. Safranin-O and fast-green were performed for structural evaluation. Results For both bovine and human samples, the dead area at the periphery of the explant was significantly smaller after scalpel blade preparation compared to harvest with OATS (P < 0.001) and powered trephine devices (P < 0.001). In addition, while powered device had a smaller remaining dead area compared to the OATS device (P < 0.001), there was significantly greater tissue loss and peripheral contour change for plugs harvested with the powered trephine device. Conclusion Our study demonstrated that OCA plugs harvested with OATS and powered device lead to a significant mechanical injury at the periphery of the explants compared to a scalpel. We propose that the optimal technique for OCA harvest utilizes a combined approach incorporating a scalpel blade/circular scalpel to prepare the chondral surface and a powered trephine to prepare the osseous surface.
  • article 1 Citação(ões) na Scopus
    Quantitative alpha-defensin testing: Is synovial fluid dilution important?
    (2022) ABDO, Rodrigo Calil Teles; GOBBI, Riccardo Gomes; LEITE, Chilan Bou Ghosson; PASOTO, Sandra Gofinet; LEON, Elaine Pires; LIMA, Ana Lucia Lei Munhoz; BONFA, Eloisa; PECORA, Jose Ricardo; DEMANGE, Marco Kawamura
    BACKGROUND Alpha-defensin has been widely studied for the diagnosis of periprosthetic joint infection (PJI). However, there is a lack of detailed information regarding the proper laboratory technique of the enzyme-linked immunosorbent assay (ELISA) method, such as sample dilution.AIM To assess the influence of dilution in the synovial fluid during ELISA for the diagnosis of knee PJI; and determine which dilution presents a better performance. METHODS Forty samples of synovial fluid from arthroplasty knees were included, 17 in the infected group and 23 in the aseptic group, according to Musculoskeletal Infection Society criteria. Initially, five synovial fluid samples from each group were assessed for quantitative analysis of alpha-defensin using ELISA. Different dilution ratios (1:10, 1:100, 1:500, 1:1000 and 1:5000) were tested based on the predetermined cutoff value of 5.2 mg/L. The dilutions that performed better were used to compare the results of all samples. RESULTS For infected cases, a gradual increase in the dilution of synovial fluid samples led to an equivalent increase in alpha-defensin level. The same was not observed in the aseptic cases. Both 1:1000 and 1:5000 dilutions presented satisfactory results to differentiate infected and aseptic cases. Further analyses were performed using 1:1000 and 1:5000 for all 40 samples. The 1:1000 dilution resulted in a sensitivity of 88.2% (95%CI, 66%-98%) and specificity of 95.7% (95%CI, 79%-99%), whereas the 1:5000 dilution presented a sensitivity of 94.1% (95%CI, 73%-99%) and a specificity of 100% (95%CI, 86%-100%). CONCLUSION The synovial fluid dilution had an important influence on the alpha-defensin ELISA results. Dilutions of 1:5000 showed the best performance for the diagnosis of knee PJI. The results of this study set the basis for a more reliable and reproducible alpha-defensin ELISA during the investigation of PJI, contributing to the expansion of this technique in different treatment centers worldwide.
  • article 6 Citação(ões) na Scopus
    ASSESSMENT OF THE USE OF TRANEXAMIC ACID AFTER TOTAL KNEE ARTHROPLASTY
    (2020) LEITE, Chilan Bou Ghosson; RANZONI, Lucas Verissimo; GIGLIO, Pedro Nogueira; BONADIO, Marcelo Batista; MELO, Lucas Da Ponte; DEMANGE, Marco Kawamura; GOBBI, Riccardo Gomes
    Objective: To evaluate the profile of blood loss and blood transfusions after the introduction of Tranexamic acid (TXA) in a tertiary university hospital in Brazil. Methods: 173 patients were retrospectively divided into two groups: the ones who received TXA and the control group. Hemoglobin levels (Hb), drain output, transfusion rates, and thromboembolic events were measured. Results: Among the patients included in this study, 82 cases received TXA. Blood transfusion occurred in 3 cases of the TXA group (3.7%), and in 27 control group cases (29.7%; p < 0.001). The average Hb decrease was 2.7 g/dl (+/- 1.39) and the median drain output was 270 mL in the TXA group. In the control group, the values were 3.41 g/dl (+/- 1.34; p < 0.001) and 460 mL (p < 0.001), respectively. Thromboembolic events occurred in 2 TXA group cases (2.4%) and in 3 control group cases (3.3%; p > 0.999). Conclusion: TXA was effective in reducing blood transfusion rates, Hb decrease, and drain output on the 1st postoperative day without increasing thromboembolic events.
  • article 0 Citação(ões) na Scopus
    Aseptically Processed Allograft Implantation: A Safe Strategy for Knee Ligament Reconstructions
    (2023) LEITE, Chilan B. G.; MONTECHI, Joao M. N.; CAMANHO, Gilberto L.; GOBBI, Riccardo G.; ANGELINI, Fabio J.
    Postoperative infections after allograft implantation is a major concern in knee ligament reconstructions considering the theoretical risk of disease transmission and its potential severity. Here, we aimed to evaluate the postoperative infection rate after knee ligament reconstructions using aseptically processed allografts, and provide an overview of the allografts use in an academic tertiary hospital. A retrospective study was performed evaluating patients who underwent knee ligament reconstructions using aseptically processed allografts, including primary and revision surgeries, from 2005 to 2018. Demographic data, including the type of knee injury and trauma energy, and postoperative data were collected focusing on postoperative infections. Regarding these infected cases, further analyses were performed considering the presenting signs and symptoms, the isolated microorganism identified in culture, the time between graft implantation and diagnosis of infection (defined as acute, subacute, and late), and the need for graft removal. A total of 180 cases of ligament reconstructions were included. The mean follow-up was 8.2 (range: 2.1-15.6) years and the mean age at surgery was 34.1 (+/- 11.1) years. A total of 262 allografts were implanted in those 180 cases, 93 (35.5%) as bone plug allografts and 169 (64.5%) as soft tissue allografts. Common surgical indications included multiligament reconstruction (57.2%) and primary anterior cruciate ligament (ACL) reconstruction (15%). Seven cases (3.9%) presented postoperative infections. Knee pain (100%) and swelling (100%) were the most prevalent symptoms. Two cases (28.6%) presented sinus tract. Allografts were removed in two cases, the same cases that presented draining sinus ( p =0.04). High-energy trauma was the only statistically associated factor for infection ( p =0.04). No significant association between infection and the type of allograft ( p >0.99) or sex ( p =0.35) were observed. Four cases (57.1%) had monomicrobial staphylococcal infections. Based on that, the allograft-related infection rate was 1.7% (the remaining three infected cases). Nonirradiated, aseptically processed allografts have a low postoperative infection rate in knee ligament reconstructions, being a safe alternative for surgeries that require additional source, increased variety, and quantity of grafts.
  • article 0 Citação(ões) na Scopus
    Identifying Anterior Cruciate Ligament Injuries Through Automated Video Analysis of In-Game Motion Patterns
    (2024) SCHULC, Attila; LEITE, Chilan B. G.; CSAKVARI, Mate; LATTERMANN, Luke; ZGODA, Molly F.; FARINA, Evan M.; LATTERMANN, Christian; TOSER, Zoltan; MERKELY, Gergo
    Background: Failure to diagnose anterior cruciate ligament (ACL) injury during a game can delay adequate treatment and increase the risk of further injuries. Artificial intelligence (AI) has the potential to be an accurate, cost-efficient, and readily available diagnostic tool for ACL injury in in-game situations.Purpose: To develop an automated video analysis system that uses AI to identify biomechanical patterns associated with ACL injury and to evaluate whether the system can enhance the ability of orthopaedic and sports medicine specialists to identify ACL injuries on video.Study Design: Descriptive laboratory study.Methods: A total of 91 ACL injury and 38 control movement scenes from online available match recordings were analyzed. The videos were processed to identify and track athletes and to estimate their 3-dimensional (3D) poses. Geometric features, including knee flexion, knee and hip abduction, and foot and hip rotation, were extracted from the athletes' 3D poses. A recurrent neural network algorithm was trained to classify ACL injury, using these engineered features as its input. Analysis by 2 orthopaedic surgeons examined whether providing clinical experts with the reconstructed 3D poses and their derived signals could increase their diagnostic accuracy.Results: All AI models performed significantly better than chance. The best model, which used the long short-term memory network with engineered features, demonstrated decision interpretability and good performance (F1 score = 0.63 +/- 0.01, area under the receiver operating characteristic curve = 0.88 +/- 0.01). The analysis by the 2 orthopaedic surgeons demonstrated improved diagnostic accuracy for ACL injury recognition when provided with system data, resulting in a 0.08 increase in combined F1 scores.Conclusion: Our approach successfully reconstructed the 3D motion of athletes from a single-camera view and derived geometry-based biomechanical features from pose sequences. Our trained AI model was able to automatically detect ACL injuries with relatively good performance and prelabel and highlight regions of interest in video footage.Clinical Relevance: This study demonstrated the feasibility of using AI to automatically evaluate in-game video footage and identify dangerous motion patterns. Further research can explore the full potential of the biomechanical markers and use of the system by nonspecialists, potentially diminishing the rate of missed diagnosis and the detrimental outcomes that follow.