ALEXANDRE AMATRUDA MARUM

Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais

Resultados de Busca

Agora exibindo 1 - 4 de 4
  • article 4 Citação(ões) na Scopus
    Pulmonary Delivery of Metoprolol Reduces Ventricular Rate During Atrial Fibrillation and Accelerates Conversion to Sinus Rhythm
    (2020) MARUM, Alexandre A.; SILVA, Bruna Araujo; BORTOLOTTO, Alexandre L.; PEDREIRA, Giovanna C.; SILVA, Fernanda Tessarolo; MEDEIROS, Sofia A.; NEARING, Bruce D.; BELARDINELLI, Luiz; VERRIER, Richard L.
    Background: Safe, effective pulmonary delivery of cardioactive agents in humans is under development. Objectives: We examined whether intratracheal delivery of metoprolol can reduce ventricular rate during atrial fibrillation (AF) and accelerate conversion to sinus rhythm. Methods: In 7 closed-chest, anesthetized Yorkshire pigs, AF was induced by intrapericardial infusion of acetylcholine (1 mL of 102.5-mM solution) followed by atrial burst pacing and was allowed to continue for 2 minutes before intratracheal instillation of sterile water or metoprolol (0.2-mg/kg bolus) using a catheter positioned at the bifurcation of the main bronchi. High-resolution electrograms were obtained from catheters fluoroscopically positioned in the right atrium and left ventricle. Results: Rapid intratracheal instillation of metoprolol caused a 32-beat/min reduction in ventricular rate during AF (from 272 +/- 13.7 to 240 +/- 12.6 beats/min, P = 0.008) and a 2.3-minute reduction in AF duration (from 10.3 +/- 2.0 to 8.0 +/- 1.4 minutes, P = 0.018) compared with sterile water control. Conversion of AF to sinus rhythm was associated with rapid restoration (5-6 minutes) of heart rate and arterial blood pressure toward control values. Intratracheal metoprolol reduced AF dominant frequency by 31% (from 8.7 +/- 0.9 to 6.0 +/- 1.1 Hz, P = 0.04) compared with control and resulted in a trend toward a 5% increase in PR interval (from 174 +/- 11.2 to 182 +/- 11.4 ms, P = 0.07). Conclusions: Intratracheal delivery of metoprolol effectively reduces ventricular rate during AF and accelerates conversion to normal sinus rhythm in a pig model of acetylcholine-induced AF.
  • article 3 Citação(ões) na Scopus
    Regadenoson-induced T-wave heterogeneity complements coronary stenosis detection by myocardial perfusion imaging in men and women
    (2021) SILVA, Bruna Araujo; HAUSER, Thomas H.; NEARING, Bruce D.; BORTOLOTTO, Alexandre L.; MARUM, Alexandre A.; SILVA, Fernanda Tessarolo; MEDEIROS, Sofia A.; PEDREIRA, Giovanna C.; V, Ernest Gervino; VERRIER, Richard L.
    Aims We analysed whether incorporating electrocardiographic interlead T-wave heterogeneity (TWH) with myocardial perfusion imaging (MPI) during pharmacologic stress improves detection of flow-limiting lesions (FLL). Methods and results Medical records of all 103 patients at our institution who underwent stress testing with regadenoson (0.4 mg IV bolus) within 3 months of coronary angiography from September 2017 to March 2019 were studied. Cases (N = 59) had angiographically significant FLL (>= 50% of left main or >= 70% of other epicardial coronary arteries >= 2 mm in diameter); controls (N = 44) were normal or had non-FLL. TWH, i.e., interlead splay of T waves, was assessed from precordial leads V4-6 by second central moment analysis. Maximum TWHV(4-6 )levels during regadenoson stress were 68% higher in cases than in controls (P < 0.0001). TWHV4-6 generated areas under the receiver-operating characteristic (ROC) curve of 0.79 in men (P < 0.0001) and 0.71 in women (P = 0.007). In men, the ROC-guided 54-mu V TWHV4-6 cut-point for FLL produced adjusted odds of 7.3 [95% confidence interval (CI): 1.3-41.5, P = 0.03], 79% sensitivity, and 78% specificity. In women, the ROC-guided 35-mu V TWHV4-6 cut-point produced adjusted odds of 4.5 (95% CI: 1.1-18.9, P = 0.04), 84% sensitivity, and 52% specificity. Adding TWHV4-6 to MPI determinations reduced false-positive results by 70%, more than doubled true-negative results, and improved adjusted odds ratio to 6.8 (95% CI: 2.2-21.4, P = 0.001) with specificity of 78% in men and 86% in women. Conclusion This observational study is the first to demonstrate the benefit of combining TWHV4-6 with MPI to enhance FLL detection during MPI with regadenoson in both men and women.
  • article 6 Citação(ões) na Scopus
    Preimplantation interlead ECG heterogeneity is superior to QRS complex duration in predicting mechanical super-response in patients with non-left bundle branch block receiving cardiac resynchronization therapy
    (2020) BORTOLOTTO, Alexandre L.; VERRIER, Richard L.; NEARING, Bruce D.; MARUM, Alexandre A.; SILVA, Bruna Araujo; PEDREIRA, Giovanna C.; SILVA, Fernanda Tessarolo; MEDEIROS, Sofia A.; SROUBEK, Jakub; ZIMETBAUM, Peter J.; CHANG, James D.
    BACKGROUND Reliable quantitative preimplantation predictors of response to cardiac resynchronization therapy (CRT) are needed. OBJECTIVE We tested the utility of preimplantation R-wave and T-wave heterogeneity (RWH and TWH, respectively) compared to standard QRS complex duration in identifying mechanical super-responders to CRT and mortality risk. METHODS We analyzed resting 12-lead electrocardiographic recordings from all 155 patients who received CRT devices between 2006 and 2018 at our institution and met class I and IIA American College of Cardiology/American Heart Association/Heart Rhythm Society guidelines with echocardiograms before and after implantation. Super-responders (n=35, 23%) had >= 20% increase in left ventricular ejection fraction and/or >= 20% decrease in left ventricular end-systolic diameter and were compared with non-super-responders (n=120, 77%), who did not meet these criteria. RWH and TWH were measured using second central moment analysis. RESULTS Among patients with non-left bundle branch block (LBBB), preimplantation RWH was significantly lower in super-responders than in non-super-responders in 3 of 4 lead sets ( P=.001 to P=.038) and TWH in 2 lead sets (both, P=.05), with the corresponding areas under the curve (RWH: 0.810-0.891, P<.001; TWH: 0.759-0.810, P <=.005). No differences were observed in the LBBB group. Preimplantation QRS complex duration also did not differ between super-responders and non-super-responders among patients with ( P=.856) or without ( P=.724) LBBB; the areas under the curve were nonsignificant (both, P=.69). RWH V1-3LILII >= 420 mu V predicted 3-year all-cause mortality in the entire cohort ( P=.037), with a hazard ratio of 7.440 (95% confidence interval 1.015-54.527; P=.048); QRS complex duration >= 150 ms did not predict mortality ( P=.27). CONCLUSION Preimplantation interlead electrocardiographic heterogeneity but not QRS complex duration predicts mechanical super-response to CRT in patients with non-LBBB.
  • conferenceObject
    STRESS-INDUCED T-WAVE HETEROGENEITY WITH REGADENOSON DETECTS CLINICALLY SIGNIFICANT CORONARY ARTERY STENOSIS
    (2019) SILVA, Bruna Araujo; NEARING, Bruce; BORTOLOTTO, Alexandre; MARUM, Alexandre; GERVINO, Ernest; VERRIER, Richard