Normative data for macular perimetry using the MP-3 microperimeter in healthy individuals

dc.contributorSistema FMUSP-HC: Faculdade de Medicina da Universidade de São Paulo (FMUSP) e Hospital das Clínicas da FMUSP
dc.contributor.authorNETO, Taurino dos Santos Rodrigues
dc.contributor.authorNETO, Epitacio Dias da Silva
dc.contributor.authorHIGASHI, Alex Haruo
dc.contributor.authorMEGNIS, Bianca Partezani
dc.contributor.authorHADDAD, Maria Aparecida Onuki
dc.contributor.authorMONTEIRO, Mario Luiz Ribeiro
dc.contributor.authorZACHARIAS, Leandro Cabral
dc.date.accessioned2024-04-05T19:33:16Z
dc.date.available2024-04-05T19:33:16Z
dc.date.issued2024
dc.description.abstractPurpose: Microperimetry has been used for several years as a form of visual function testing in patients with retinal diseases. Normal microperimetry values obtained with microperimeter MP-3 have not yet been fully published, and baseline values for topographic macular sensitivity and correlations with age and sex are needed to establish degrees of impairment. This study aimed to determine values for light sensitivity thresholds and fixation stability using the MP-3 in healthy individuals. Methods: Thirty-seven healthy volunteers (age, 28-68 years), underwent full-threshold microperimetry using a 4-2 (fast) staircase strategy with the standard Goldmann III stimulus size and 68 test points positioned identically to those in the Humphrey Field Analyzer 10-2 test grid. The fixation stability was simultaneously recorded during the microperimetry test. The relationship between global sensitivity and age was calculated using linear regression analysis. Results: Microperimetry was performed on 37 participants (74 eyes). The global mean sensitivity was 29.01 +/- 1.44 (range, 26-31) dB. The mean central sensitivity at 2 degrees measured by the MP-3 was 28.5 +/- 1.77 dB in the right eye (OD) and 28.75 +/- 1.98 dB in the left eye (OS). The total median fixation stability values within 2 degrees and 4 degrees were 80% and 96%, respectively. The linear regression analysis also revealed an age-related global sensitivity decline per year of -0.051 dB +/- 0.018 (OD) and -0.078 dB +/- 0.021 (OS). Conclusions: Microperimetry performed with the MP-3 allows for an automatic, accurate, and topography-specific examination of retinal sensitivity thresholds. The results of this study provide a normal and age-matched database of MP-3 microperimetry.eng
dc.description.indexMEDLINE
dc.description.indexPubMed
dc.description.indexScopus
dc.description.indexDimensions
dc.description.indexWoS
dc.description.sponsorshipCAPES-Coordenacao de Aperfeicoamento de Nivel Superior, Brasilia, Brazil
dc.identifier.citationARQUIVOS BRASILEIROS DE OFTALMOLOGIA, v.87, n.5, article ID e20210472, 7p, 2024
dc.identifier.doi10.5935/0004-2749.2021-0472
dc.identifier.eissn1678-2925
dc.identifier.issn0004-2749
dc.identifier.urihttps://observatorio.fm.usp.br/handle/OPI/58926
dc.language.isoeng
dc.publisherCONSEL BRASIL OFTALMOLOGIAeng
dc.relation.ispartofArquivos Brasileiros de Oftalmologia
dc.rightsopenAccesseng
dc.rights.holderCopyright CONSEL BRASIL OFTALMOLOGIAeng
dc.subjectVisual fieldseng
dc.subjectVisual field testseng
dc.subjectRetinaeng
dc.subjectMicroperi- metryeng
dc.subjectAgeeng
dc.subject.othersensitivityeng
dc.subject.wosOphthalmologyeng
dc.titleNormative data for macular perimetry using the MP-3 microperimeter in healthy individualseng
dc.typearticleeng
dc.type.categoryoriginal articleeng
dc.type.versionpublishedVersioneng
dspace.entity.typePublication
hcfmusp.citation.scopus0
hcfmusp.contributor.author-fmusphcTAURINO DOS SANTOS RODRIGUES NETO
hcfmusp.contributor.author-fmusphcEPITACIO DIAS DA SILVA NETO
hcfmusp.contributor.author-fmusphcALEX HARUO HIGASHI
hcfmusp.contributor.author-fmusphcBIANCA PARTEZANI MEGNIS
hcfmusp.contributor.author-fmusphcMARIA APARECIDA ONUKI HADDAD
hcfmusp.contributor.author-fmusphcMARIO LUIZ RIBEIRO MONTEIRO
hcfmusp.contributor.author-fmusphcLEANDRO CABRAL ZACHARIAS
hcfmusp.description.articlenumbere20210472
hcfmusp.description.issue5
hcfmusp.description.volume87
hcfmusp.origemWOS
hcfmusp.origem.dimensionspub.1157070285
hcfmusp.origem.pubmed37018820
hcfmusp.origem.scopus2-s2.0-85184190080
hcfmusp.origem.wosWOS:001153983600001
hcfmusp.publisher.citySAO PAULOeng
hcfmusp.publisher.countryBRAZILeng
hcfmusp.relation.referenceActon JH, 2013, CAN J OPHTHALMOL, V48, P358, DOI 10.1016/j.jcjo.2013.03.021eng
hcfmusp.relation.referenceBalasubramanian S, 2018, BRIT J OPHTHALMOL, V102, P109, DOI 10.1136/bjophthalmol-2017-310258eng
hcfmusp.relation.referenceFujino R, 2020, GRAEF ARCH CLIN EXP, V258, P1949, DOI 10.1007/s00417-020-04759-9eng
hcfmusp.relation.referenceJOHNSON CA, 1989, INVEST OPHTH VIS SCI, V30, P2056eng
hcfmusp.relation.referenceLACHENMAYR BJ, 1994, INVEST OPHTH VIS SCI, V35, P2741eng
hcfmusp.relation.referenceLaishram M, 2017, J CLIN DIAGN RES, V11, pNC08, DOI 10.7860/JCDR/2017/25799.10213eng
hcfmusp.relation.referenceMarkowitz SN, 2013, CAN J OPHTHALMOL, V48, P350, DOI 10.1016/j.jcjo.2012.03.004eng
hcfmusp.relation.referenceMidena E, 2007, BRIT J OPHTHALMOL, V91, P1499, DOI 10.1136/bjo.2007.119685eng
hcfmusp.relation.referenceMidena E, 2010, OPHTHALMOLOGY, V117, P1571, DOI 10.1016/j.ophtha.2009.12.044eng
hcfmusp.relation.referencePalkovits S, 2018, TRANSL VIS SCI TECHN, V7, DOI 10.1167/tvst.7.1.17eng
hcfmusp.relation.referenceBarboni MTS, 2018, TRANSL VIS SCI TECHN, V7, DOI 10.1167/tvst.7.2.25eng
hcfmusp.relation.referenceShah VA, 2009, OPHTHALMIC RES, V41, P9, DOI 10.1159/000162111eng
hcfmusp.relation.referenceVujosevic S, 2006, INVEST OPHTH VIS SCI, V47, P3044, DOI 10.1167/iovs.05-1141eng
hcfmusp.relation.referenceYamaike N, 2007, AM J OPHTHALMOL, V143, P342, DOI 10.1016/j.ajo.2006.09.034eng
hcfmusp.scopus.lastupdate2024-05-17
relation.isAuthorOfPublicatione55c1fde-2b0a-4b27-95e1-e2d8385fc733
relation.isAuthorOfPublication506c585a-59af-418d-a54f-1073dd7f88e3
relation.isAuthorOfPublication7e03843d-d136-4b66-b990-7c33b7933c63
relation.isAuthorOfPublication1d69a1e6-2d08-41e4-82e1-f2db12fa7c3d
relation.isAuthorOfPublication03f8cba3-220f-451b-87d1-aea5f70d5b56
relation.isAuthorOfPublication49360274-203b-489e-a263-d0aba4cb5be3
relation.isAuthorOfPublication4776bc95-698a-49ff-b8cb-d31953316997
relation.isAuthorOfPublication.latestForDiscoverye55c1fde-2b0a-4b27-95e1-e2d8385fc733
Arquivos