Endoscopic Treatment of Complex Walled-Off Necrosis in Necrotizing Pancreatitis With Two Simultaneous Lumen-Apposing Metal Stents: A Case Report

Carregando...
Imagem de Miniatura
Citações na Scopus
Tipo de produção
article
Data de publicação
2022
Título da Revista
ISSN da Revista
Título do Volume
Editora
CUREUS INC
Citação
CUREUS JOURNAL OF MEDICAL SCIENCE, v.14, n.10, article ID e30930, 8p, 2022
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
Organized pancreatic and peripancreatic collections are complications of pancreatitis and should be treated when symptomatic or complicated. When feasible, the endoscopic ultrasound approach presents high efficacy and low morbidity and mortality, making it the first likely option. Among the available accessories for endoscopic drainage, the lumen-apposing metal stent can be a better option, with a low migration rate; furthermore, it allows endoscopic necrosectomy. Here, we present the case of complex walled-off necrosis treated with two lumen-apposing metal stents in the same procedure. A 41-year-old male patient with walled-off necrosis presented with delayed gastric emptying and obstruction of the main biliary duct. Magnetic resonance imaging and endoscopic ultrasound revealed two non-communicating collections. We opted for endoscopic ultrasound-guided drainage with the deployment of two simultaneous lumen-apposing metal stents: one transduodenal and the other transgastric, with clinical improvement. After three weeks, endoscopic retrograde cholangiopancreatography showed a biliary fistula communicating with the periduodenal collection, which was treated with a biliary plastic stent. An endoscopic necrosectomy was performed, and the metal stents were removed. Control magnetic resonance imaging demonstrated improvement. The patient was asymptomatic at the six-month follow-up. The treatment of symptomatic complex walled-off necrosis remains a challenge and may require multiple endoscopic approaches; moreover, surgical treatment may be necessary in case of failure. In the present report, we demonstrate that the deployment of two lumen-apposing metal stents in the same procedure is feasible when necessary as it was associated with technical success and short-term clinical success.
Palavras-chave
pancreatic necrosis, endoscopic ultrasound, endoscopic necrosectomy, lumen-apposing metal stent, walled-off necroses
Referências
  1. Alali A, 2017, CLIN ENDOSC, V50, P117, DOI 10.5946/ce.2017.045
  2. Arvanitakis M, 2018, ENDOSCOPY, V50, P524, DOI 10.1055/a-0588-5365
  3. Aslam S, 2021, CUREUS, V13, DOI 10.7759/cureus.15981
  4. Bang JY, 2020, DIGEST ENDOSC, V32, P298, DOI 10.1111/den.13470
  5. Banks PA, 2013, GUT, V62, P102, DOI 10.1136/gutjnl-2012-302779
  6. Baron TH, 2020, GASTROENTEROLOGY, V158, P67, DOI 10.1053/j.gastro.2019.07.064
  7. Calo Natalia Causada, 2022, J Can Assoc Gastroenterol, V5, P68, DOI 10.1093/jcag/gwab024
  8. DE-Moura DT, 2019, ABCD-ARQ BRAS CIR DI, V32, P1430, DOI [10.1590/0102-672020180001e1430, DOI 10.1590/0102-672020180001E1430]
  9. Farias GFA, 2019, MEDICINE, V98, DOI 10.1097/MD.0000000000014255
  10. Gluck M, 2012, J GASTROINTEST SURG, V16, P248, DOI 10.1007/s11605-011-1759-4
  11. Guo JT, 2017, ENDOSC ULTRASOUND, V6, P285, DOI 10.4103/eus.eus_85_17
  12. Hookey LC, 2006, GASTROINTEST ENDOSC, V63, P635, DOI 10.1016/j.gie.2005.06.028
  13. Khan A, 2012, CELL TRANSPLANT, V21, P1261, DOI 10.3727/096368911X600984
  14. Lera ME, 2019, ENDOSCOPY, V51, pE77, DOI 10.1055/a-0820-1456
  15. Muthusamy VR, 2016, GASTROINTEST ENDOSC, V83, P481, DOI 10.1016/j.gie.2015.11.027
  16. Onnekink AM, 2022, GASTROENTEROLOGY, V163, P712, DOI 10.1053/j.gastro.2022.05.015
  17. Papachristou GI, 2007, ANN SURG, V245, P943, DOI 10.1097/01.sla.0000254366.19366.69
  18. van Brunschot S, 2018, LANCET, V391, P51, DOI 10.1016/S0140-6736(17)32404-2
  19. van Santvoort HC, 2010, NEW ENGL J MED, V362, P1491, DOI 10.1056/NEJMoa0908821
  20. Zhang LY, 2022, ENDOSCOPY, V54, P706, DOI 10.1055/a-1682-7095