Hybrid Breast Augmentation: A Reliable Formula for Preoperative Assessment of Fat Graft Volume Based on Implant Volume and Projection
dc.contributor | Sistema FMUSP-HC: Faculdade de Medicina da Universidade de São Paulo (FMUSP) e Hospital das Clínicas da FMUSP | |
dc.contributor.author | MAXIMILIANO, Joao | |
dc.contributor.author | MUNHOZ, Alexandre Mendonca | |
dc.contributor.author | PEDRON, Mirian | |
dc.contributor.author | OLIVEIRA, Antonio Carlos Pinto de | |
dc.contributor.author | DUARTE, Daniele Walter | |
dc.contributor.author | NETO, Rafael | |
dc.contributor.author | PORTINHO, Ciro Paz | |
dc.contributor.author | COLLARES, Marcos Vinicius Martins | |
dc.date.accessioned | 2021-04-15T20:03:17Z | |
dc.date.available | 2021-04-15T20:03:17Z | |
dc.date.issued | 2020 | |
dc.description.abstract | Background: Autogenous fat grafting (AFG) is an established technique used as an adjunct to breast augmentation (BA) to redesign breast shape. Surgeons often use experience and intuition to estimate AFG volume, which can result in incorrect assessment of donor areas and unnecessary fat removal. Objectives: This aim of this study was to develop a method based on a mathematical formula, which utilizes implant volume and projection to predict AFG volume. Methods: Thirty patients (60 breasts) underwent primary hybrid BA. A software package (SketchUp) was used to simulate 3-dimensional AFG and implant volumes, which in turn were used to develop an equation for estimating AFG volume according to 3 different implant projections. The results for each group were compared, via Pearson's correlation coefficient, with the results of the clinical series. Results: All patients received Motiva Ergonomix SmoothSilk/SilkSurface implants, ranging in volume from 175 to 355 cc (mean, 265 cc), as well as an average AFG volume of 79.2 cc/breast (range, 50-110 cc). Twenty-nine patients (96.6%) were either very satisfied or satisfied during a mean follow-up of 18 months (range, 6-28 months). A high correlation was observed between the AFG performed in the cohort and predictions obtained from the formula (r = 0.938, P < 0.001). Conclusions: The AFG volume in hybrid BA procedures can be estimated utilizing measurements based on implant volume/ projection. This low-cost method can be applied to guide surgical decision-making in patients who are candidates for BA. | eng |
dc.description.index | MEDLINE | eng |
dc.identifier.citation | AESTHETIC SURGERY JOURNAL, v.40, n.8, p.NP438-NP452, 2020 | |
dc.identifier.doi | 10.1093/asj/sjaa017 | |
dc.identifier.eissn | 1527-330X | |
dc.identifier.issn | 1090-820X | |
dc.identifier.uri | https://observatorio.fm.usp.br/handle/OPI/40051 | |
dc.language.iso | eng | |
dc.publisher | OXFORD UNIV PRESS INC | eng |
dc.relation.ispartof | Aesthetic Surgery Journal | |
dc.rights | restrictedAccess | eng |
dc.rights.holder | Copyright OXFORD UNIV PRESS INC | eng |
dc.subject.other | autologous fat | eng |
dc.subject.other | experience | eng |
dc.subject.other | mammaplasty | eng |
dc.subject.other | tissue | eng |
dc.subject.other | model | eng |
dc.subject.other | safe | eng |
dc.subject.other | soft | eng |
dc.subject.wos | Surgery | eng |
dc.title | Hybrid Breast Augmentation: A Reliable Formula for Preoperative Assessment of Fat Graft Volume Based on Implant Volume and Projection | eng |
dc.type | article | eng |
dc.type.category | original article | eng |
dc.type.version | publishedVersion | eng |
dspace.entity.type | Publication | |
hcfmusp.author.external | MAXIMILIANO, Joao:Hosp Clin Porto Alegre, Div Plast Surg, Porto Alegre, RS, Brazil | |
hcfmusp.author.external | OLIVEIRA, Antonio Carlos Pinto de:Hosp Clin Porto Alegre, Div Plast Surg, Porto Alegre, RS, Brazil | |
hcfmusp.author.external | DUARTE, Daniele Walter:Hosp Clin Porto Alegre, Div Plast Surg, Porto Alegre, RS, Brazil | |
hcfmusp.author.external | NETO, Rafael:Hosp Moinhos Vento, Div Plast Surg, Porto Alegre, RS, Brazil | |
hcfmusp.author.external | PORTINHO, Ciro Paz:Hosp Clin Porto Alegre, Div Plast Surg, Porto Alegre, RS, Brazil | |
hcfmusp.author.external | COLLARES, Marcos Vinicius Martins:Hosp Clin Porto Alegre, Plast Surg Div, Porto Alegre, RS, Brazil | |
hcfmusp.citation.scopus | 25 | |
hcfmusp.contributor.author-fmusphc | ALEXANDRE MENDONCA MUNHOZ | |
hcfmusp.description.beginpage | NP438 | |
hcfmusp.description.endpage | NP452 | |
hcfmusp.description.issue | 8 | |
hcfmusp.description.volume | 40 | |
hcfmusp.origem | WOS | |
hcfmusp.origem.pubmed | 31960904 | |
hcfmusp.origem.scopus | 2-s2.0-85088486131 | |
hcfmusp.origem.wos | WOS:000610423000001 | |
hcfmusp.publisher.city | CARY | eng |
hcfmusp.publisher.country | USA | eng |
hcfmusp.relation.reference | Abboud MH, 2015, AESTHET SURG J, V35, P819, DOI 10.1093/asj/sjv073 | eng |
hcfmusp.relation.reference | Adams WP, 2012, PLAST RECONSTR SURG, V130, p598E, DOI 10.1097/PRS.0b013e318262f607 | eng |
hcfmusp.relation.reference | American Society of Plastic Surgeons (ASPS), 2018 PLAST SURG STAT | eng |
hcfmusp.relation.reference | [Anonymous], STUD SAF EFF MOT IMP | eng |
hcfmusp.relation.reference | Auclair E, 2015, CLIN PLAST SURG, V42, P307, DOI 10.1016/j.cps.2015.03.005 | eng |
hcfmusp.relation.reference | Auclair E, 2013, PLAST RECONSTR SURG, V132, P558, DOI 10.1097/PRS.0b013e31829ad2fa | eng |
hcfmusp.relation.reference | Aygit AC, 2013, PLAST RECONSTR SURG, V131, P1149, DOI 10.1097/PRS.0b013e3182865d68 | eng |
hcfmusp.relation.reference | Bangeas P, 2016, INTERACT CARDIOV TH, V22, P513, DOI 10.1093/icvts/ivv395 | eng |
hcfmusp.relation.reference | Benito-Ruiz J, 2009, PLAST RECONSTR SURG, V123, p31E, DOI 10.1097/PRS.0b013e31819055b5 | eng |
hcfmusp.relation.reference | Bravo FG, 2015, PLAST RECONSTR SURG, V135, P1010, DOI 10.1097/PRS.0000000000001052 | eng |
hcfmusp.relation.reference | CARPANEDA CA, 1994, AESTHET PLAST SURG, V18, P17, DOI 10.1007/BF00444242 | eng |
hcfmusp.relation.reference | Caruso MK, 2006, AESTHET PLAST SURG, V30, P16, DOI 10.1007/s00266-004-0105-6 | eng |
hcfmusp.relation.reference | Quiros MC, 2019, AESTHET SURG J, V39, P495, DOI 10.1093/asj/sjy196 | eng |
hcfmusp.relation.reference | Chan CW, 2008, J PLAST RECONSTR AES, V61, P1438, DOI 10.1016/j.bjps.2008.08.006 | eng |
hcfmusp.relation.reference | Chang EI, 2018, PLAST RECONSTR SURG, V142, p31S, DOI 10.1097/PRS.0000000000005000 | eng |
hcfmusp.relation.reference | Coleman SR, 2001, CLIN PLAST SURG, V28, P111 | eng |
hcfmusp.relation.reference | Coleman SR, 2007, PLAST RECONSTR SURG, V119, P775, DOI 10.1097/01.prs.0000252001.59162.c9 | eng |
hcfmusp.relation.reference | Del Vecchio DA, 2012, PLAST RECONSTR SURG, V130, P1187, DOI 10.1097/PRS.0b013e31826d9c3c | eng |
hcfmusp.relation.reference | Eisinga R, 2013, INT J PUBLIC HEALTH, V58, P637, DOI 10.1007/s00038-012-0416-3 | eng |
hcfmusp.relation.reference | Tijerina VNE, 2010, AESTHET PLAST SURG, V34, P16, DOI 10.1007/s00266-009-9402-4 | eng |
hcfmusp.relation.reference | Gir P, 2012, PLAST RECONSTR SURG, V130, P249, DOI 10.1097/PRS.0b013e318254b4d3 | eng |
hcfmusp.relation.reference | Goes JCS, 2003, AESTHET PLAST SURG, V27, P178, DOI 10.1007/s00266-003-0004-2 | eng |
hcfmusp.relation.reference | Govsa F, 2017, EUR ARCH OTO-RHINO-L, V274, P1097, DOI 10.1007/s00405-016-4355-0 | eng |
hcfmusp.relation.reference | Graf RM, 2000, AESTHET PLAST SURG, V24, P216, DOI 10.1007/s002660010036 | eng |
hcfmusp.relation.reference | Graf RM, 2003, PLAST RECONSTR SURG, V111, P904, DOI 10.1097/01.PRS.0000041601.59651.15 | eng |
hcfmusp.relation.reference | GROSSMAN AJ, 1980, PLAST RECONSTR SURG, V66, P851, DOI 10.1097/00006534-198012000-00009 | eng |
hcfmusp.relation.reference | Hidalgo DA, 2000, PLAST RECONSTR SURG, V105, P2202, DOI 10.1097/00006534-200005000-00047 | eng |
hcfmusp.relation.reference | Higgins WE, 1998, RADIOGRAPHICS, V18, P761, DOI 10.1148/radiographics.18.3.9599397 | eng |
hcfmusp.relation.reference | Huemer GM, 2018, PLAST RECONSTR SURG, V141, p831E, DOI 10.1097/PRS.0000000000004367 | eng |
hcfmusp.relation.reference | Hunstad JP, 2010, AESTHET PLAST SURG, V34, P365, DOI 10.1007/s00266-009-9466-1 | eng |
hcfmusp.relation.reference | Kerfant N, 2017, PLAST RECONSTR SURG, V139, p1080E, DOI 10.1097/PRS.0000000000003299 | eng |
hcfmusp.relation.reference | Khouri RK, 2012, PLAST RECONSTR SURG, V129, P1173, DOI 10.1097/PRS.0b013e31824a2db6 | eng |
hcfmusp.relation.reference | Kocak E, 2011, PLAST RECONSTR SURG, V127, P1059, DOI 10.1097/PRS.0b013e318205f18d | eng |
hcfmusp.relation.reference | Lin J, 2006, PLAST RECONSTR SURG, V118, P1557, DOI 10.1097/01.prs.0000237002.89761.98 | eng |
hcfmusp.relation.reference | LIN LI, 1989, BIOMETRICS, V45, P255, DOI 10.2307/2532051 | eng |
hcfmusp.relation.reference | Lista F, 2013, PLAST RECONSTR SURG, V132, P1684, DOI 10.1097/PRS.0b013e3182a80880 | eng |
hcfmusp.relation.reference | Serra-Mestre JM, 2017, PLAST RECONSTR SURG, V140, p665E, DOI 10.1097/PRS.0000000000003788 | eng |
hcfmusp.relation.reference | Munhoz AM, 2006, AESTHET PLAST SURG, V30, P503, DOI 10.1007/s00266-006-0017-8 | eng |
hcfmusp.relation.reference | Munhoz AM, 2007, ANN PLAS SURG, V58, P141, DOI 10.1097/01.sap.0000237762.99536.77 | eng |
hcfmusp.relation.reference | Munhoz AM, 2020, AESTHET SURG J, V40, P1179, DOI 10.1093/asj/sjz339 | eng |
hcfmusp.relation.reference | Munhoz AM, 2015, CLIN PLAST SURG, V42, P565, DOI 10.1016/j.cps.2015.06.016 | eng |
hcfmusp.relation.reference | Ng CL, 2015, OTOLARYNG HEAD NECK, V153, P832, DOI 10.1177/0194599815584600 | eng |
hcfmusp.relation.reference | Ratib O, 2000, RADIOGRAPHICS, V20, P1807, DOI 10.1148/radiographics.20.6.g00nv191807 | eng |
hcfmusp.relation.reference | Saint-Cyr M, 2012, J RECONSTR MICROSURG, V28, P99, DOI 10.1055/s-0031-1287675 | eng |
hcfmusp.relation.reference | Goes JCS, 2015, CLIN PLAST SURG, V42, P551, DOI 10.1016/j.cps.2015.06.017 | eng |
hcfmusp.relation.reference | Serra-Renom JM, 2005, PLAST RECONSTR SURG, V116, P640, DOI 10.1097/01.prs.0000173558.52280.6e | eng |
hcfmusp.relation.reference | Sforza M, 2019, AESTHET SURG J, V39, pS95, DOI 10.1093/asj/sjz054 | eng |
hcfmusp.relation.reference | Sforza M, 2018, AESTHET SURG J, V38, pS62, DOI 10.1093/asj/sjx150 | eng |
hcfmusp.relation.reference | Stoff-Khalili MA, 2004, PLAST RECONSTR SURG, V114, P1280, DOI 10.1097/01.PRS.0000135906.48388.22 | eng |
hcfmusp.relation.reference | Tezel E, 2000, PLAST RECONSTR SURG, V105, P1019, DOI 10.1097/00006534-200003000-00028 | eng |
hcfmusp.relation.reference | Ventura OD, 2005, AESTHET PLAST SURG, V29, P379, DOI 10.1007/s00266-004-0019-3 | eng |
hcfmusp.relation.reference | Wesselius TS, 2018, EUR J PLAST SURG, V41, P663, DOI 10.1007/s00238-018-1431-2 | eng |
hcfmusp.relation.reference | WILKIE T, 1977, AESTHET PLAST SURG, V1, P301, DOI 10.1007/BF01570265 | eng |
hcfmusp.relation.reference | Young VL, 2001, CLIN PLAST SURG, V28, P451 | eng |
hcfmusp.relation.reference | Zheng DN, 2008, J PLAST RECONSTR AES, V61, P792, DOI 10.1016/j.bjps.2007.08.036 | eng |
hcfmusp.scopus.lastupdate | 2024-05-17 | |
relation.isAuthorOfPublication | 6f507ada-b0be-4c50-bd94-1f0116c9184c | |
relation.isAuthorOfPublication.latestForDiscovery | 6f507ada-b0be-4c50-bd94-1f0116c9184c |
Arquivos
Pacote Original
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- art_MAXIMILIANO_Hybrid_Breast_Augmentation_A_Reliable_Formula_for_Preoperative_2020.PDF
- Tamanho:
- 1.31 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
- publishedVersion (English)