MARIA VALERIA SCHMIDT GOFFI GOMEZ

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/32 - Laboratório de Otorrinolaringologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 10 de 20
  • article 1 Citação(ões) na Scopus
    Speech Perception Performance of Double Array Multichannel Cochlear Implant Users With Standard and Duplicated Maps in Each of the Arrays
    (2013) BENTO, Ricardo Ferreira; GOFFI-GOMEZ, Maria Valeria Schmidt; TSUJI, Robinson Koji; FONSECA, Anna Carolina de Oliveira; IKARI, Liliane Satomi; BRITO NETO, Rubens Vuono de
    Objective: The present investigation evaluated the speech perception performance of patients with ossified cochlea implanted with the 24M Double Array cochlear implant, using standard and duplicated maps in each of the arrays. Study Design: Retrospective case review. Setting: Tertiary referral center. Patients: Sixteen subjects received a Double Array cochlear implant. Among these, 9 fulfilled the following inclusion criteria: bilateral severe-to- profound postlingual deafness; bilateral obliterated cochlea, as shown by a computed tomographic scan; and a minimum age of 14 years to ensure reliable responses in the behavioral tests with the 3 tested maps. Intervention: Rehabilitative. Main Outcome Measures: The speech perception performance with the 2 arrays was compared with that with a basal array duplicated map and an apical array duplicated map. Three maps were fitted: the default map with both arrays activated, a double channel map using only the electrodes of the basal array, and a double channel map programmed only with the electrodes of the apical array. The test battery was composed of a vowel test, a 4-choice word test, and sentence recognition in quiet. Results: Statistical significance was reached in comparison the all tests in all programming conditions. Speech recognition in the standard map with both electrode arrays activated showed the highest scores. Conclusion: Performance with the 2 split electrode arrays was superior to those with the single arrays, regardless of the duplication of channels.
  • article 5 Citação(ões) na Scopus
    Microangiopathy of the inner ear, deafness, and cochlear implantation in a patient with Susac syndrome
    (2011) BITTENCOURT, Aline Gomes; SANTOS, Andrea Felice Dos; GOFFI-GOMEZ, Maria Valeria Schmidt; KUTSCHER, Kellen; TSUJI, Robinson Koji; BRITO, Rubens De; BENTO, Ricardo Ferreira
    Conclusion: The cochlear implant was beneficial as an attempt to restore hearing and improve communication abilities in this patient with profound sensorineural hearing loss secondary to Susac syndrome. Objective: To report the audiological outcomes of cochlear implantation (CI) in a young woman with Susac syndrome after a 6-month follow-up period. Susac syndrome is a rare disorder. It is clinically characterized by a typical triad of sensorineural deafness, encephalopathy, and visual defect, due to microangiopathy involving the brain, inner ear, and retina. Methods: This was a retrospective review of a case at a tertiary referral center. After diagnosis, the patient was evaluated by a multidisciplinary team and received a cochlear implant in her right ear. Results: The patient achieved 100% open-set sentence recognition in noise conditions and 92% monosyllable and 68% medial consonant recognition in quiet conditions after 6 months of implant use. She reported the use of the telephone 3 months after activation.
  • article 15 Citação(ões) na Scopus
    Hearing preservation using topical dexamethasone alone and associated with hyaluronic acid in cochlear implantation
    (2015) RAMOS, Bernardo Faria; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira; GOFFI-GOMEZ, Maria Valeria Schmidt; RAMOS, Henrique Faria; SAMUEL, Paola Angelica; BRITO, Rubens
    Conclusion: Topical dexamethasone associated with hyaluronic acid in cochlear implant surgery demonstrated a statistically significant difference in the preservation of low-frequency thresholds when compared with topical dexamethasone alone and a control group. Topical dexamethasone alone was not superior in hearing preservation when compared to the control group. Objective: To compare the effects of topical dexamethasone alone and associated with hyaluronic acid intraoperatively in hearing preservation in cochlear implantation. Methods: Eighteen severely to profoundly hearing-impaired adult patients with measurable hearing were divided into three groups preoperatively: cochlear implantation as a control group (group 1), cochlear implantation using topical dexamethasone intraoperatively (group 2), and cochlear implantation using topical dexamethasone associated with hyaluronic acid intraoperatively (group 3). Preimplant and postimplant low-frequency pure-tone averages (PTAs) were calculated from unaided audiograms at 125, 250, and 500 Hz. Results: The mean changes in the low-frequency PTA comparing postoperative against preoperative thresholds were 28.03 +/- 6.77 dB in group 1, 30 +/- 14.53 dB in group 2, and 7.23 +/- 6.12 dB in group 3. There was statistical difference when comparing group 3 with groups 1 and 2 using one-way ANOVA (p = 0.002) followed by Scheffe post hoc test.
  • article 0 Citação(ões) na Scopus
    Is There Any Correlation between Spread of Excitation Width and the Refractory Properties of the Auditory Nerve in Cochlear Implant Users?
    (2021) SILVA, Juliana Coutinho da; GOFFI-GOMEZ, Maria Valeria Schmidt; TSUJI, Robinson Koji; BENTO, Ricardo; BRITO NETO, Rubens
    Background: The spread of excitation (SOE) and auditory nerve recovery function (REC) are objective measures recorded by neural response telemetry and may interfere in cochlear implant (CI) stimulation. Objective: To analyze and correlate SOE with the refractory periods in subjects with pre- and postlingual deafness implanted with different electrode arrays. Methods: This was a retrospective study of 323 ears separated by perimodiolar or straight arrays and by pre- or postlingually deaf recipients. Measures were collected intraoperatively on electrode 11. The SOE width was measured in millimeters at the 0.75 point of the curve, and the relative (tau) and absolute (t0) refractory periods were measured in microseconds. Results: There was a statistical correlation between the SOE and the t0 in the patients with postlingual deafness implanted with the perimodiolar array. The SOE width was statistically different between the straight and perimodiolar arrays and between the pre- and postlingual groups in the perimodiolar array. Tau was statistically different between the pre- and postlingual groups with the straight array and the t0, between the pre- and postlingual groups with the perimodiolar array. Neural response threshold and amplitude of the neural response were not statistically different among groups. Conclusion: There was a correlation between SOE width and t0 only in patients with acquired deafness. The findings suggest that different factors influence SOE and REC, considering SOE is different according to the electrode array and REC being different according the onset of deafness.
  • article 10 Citação(ões) na Scopus
    Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation
    (2013) BENTO, Ricardo Ferreira; MONTEIRO, Tatiana Alves; BITTENCOURT, Aline Gomes; GOFFI-GOMEZ, Maria Valeria Schmidt; BRITO, Rubens de
    INTRODUCTION: Few cases of cochlear implantation (CI) in neurofibromatosis type 2 (NF2) patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. OBJECTIVES: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. RESUMED REPORT: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. CONCLUSION: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.
  • article 9 Citação(ões) na Scopus
    Are Auditory Steady-State Responses Useful to Evaluate Severe-to-Profound Hearing Loss in Children?
    (2015) GRASEL, Signe Schuster; ALMEIDA, Edigar Rezende de; BECK, Roberto Miquelino de Oliveira; GOFFI-GOMEZ, Maria Valeria Schmidt; RAMOS, Henrique Faria; ROSSI, Amanda Costa; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira; BRITO, Rubens de
    Objective. To evaluate Auditory Steady-State Responses (ASSR) at high intensities in pediatric cochlear implant candidates and to compare the results to behavioral tests responses. Methods. This prospective study evaluated 42 children with suspected severe-to-profound hearing loss, aged from 3 to 72 months. All had absent ABR and OAE responses. ASSR were evoked using binaural single frequency stimuli at 110 dB HL with a 10 dB down-seeking procedure. ASSR and behavioral test results were compared. Results. Forty-two subjects completed both ASSR and behavioral evaluation. Eleven children (26.2%) had bilateral responses. Four (9.5%) showed unilateral responses in at least two frequencies, all confirmed by behavioral results. Overall 61 ASSR responses were obtained, most (37.7%) in 500 Hz. Mean thresholds were between 101.3 and 104.2 dB HL. Among 27 subjects with absent ASSR, fifteen had no behavioral responses. Seven subjects showed behavioral responses with absent ASSR responses. No spurious ASSR responses were observed at 100 or 110 dB HL. Conclusion. ASSR is a valuable tool to detect residual hearing. No false-positive ASSR results were observed among 42 children, but in seven cases with absent ASSR, the test underestimated residual hearing as compared to the behavioral responses.
  • article 6 Citação(ões) na Scopus
    Longitudinal Analysis of the Absence of Intraoperative Neural Response Telemetry in Children using Cochlear Implants
    (2014) MOURA, Amanda Christina Gomes de; GOFFI-GOMEZ, Maria Valéria Schmidt; COUTO, Maria Ines Vieira; BRITO, Rubens; TSUJI, Robinson Koji; BEFI-LOPES, Debora Maria; MATAS, Carla Gentile; BENTO, Ricardo Ferreira
    Introduction Currently the cochlear implant allows access to sounds in individuals with profound hearing loss. The objective methods used to verify the integrity of the cochlear device and the electrophysiologic response of users have noted these improvements. Objective To establish whether the evoked compound action potential of the auditory nerve can appear after electrical stimulation when it is absent intraoperatively. Methods The clinical records of children implanted with the Nucleus Freedom (Cochlear Ltd., Australia) (CI24RE) cochlear implant between January 2009 and January 2010 with at least 6 months of use were evaluated. The neural response telemetry (NRT) thresholds of electrodes 1, 6, 11, 16, and 22 during surgery and after at least 3 months of implant use were analyzed and correlated with etiology, length of auditory deprivation, and chronological age. These data were compared between a group of children exhibiting responses in all of the tested electrodes and a group of children who had at least one absent response. Results The sample was composed of clinical records of 51 children. From these, 21% (11) showed no NRT in at least one of the tested electrodes. After an average of 4.9 months of stimulation, the number of individuals exhibiting absent responses decreased from 21 to 11% (n = 6). Conclusion It is feasible that absent responses present after a period of electrical stimulation. In our sample, 45% (n = 5) of the patients with intraoperative absence exhibited a positive response after an average of 4.9 months of continued electrical stimulation.
  • article 8 Citação(ões) na Scopus
    Satisfação e qualidade de vida em usuários de implante auditivo de tronco cerebral
    (2017) FERNANDES, Nayara Freitas; GOFFI-GOMEZ, Maria Valéria Schmidt; MAGALHÃES, Ana Tereza De Matos; TSUJI, Robinson Koji; DE BRITO, Rubens Vuono; BENTO, Ricardo Ferreira
    ABSTRACT Purpose To evaluate satisfaction and quality of life of users of Auditory Implant Brainstem. Methods This is a cross-sectional and descriptive study conducted at Divisão de Clínica Otorrinolaringológica of Hospital das Clínicas of Faculdade de Medicina da Universidade de São Paulo, Brazil. For the research, 19 users of an Auditory Brainstem Implant answered the following questionnaires: KINDLR (Questionnaire for Measuring Health-Related Quality of Life in Children and Adolescents), for children and adolescents, their parents and/or caregivers; WHOQOL-BREF questionnaire, for adult participants; and the Satisfaction with Amplification in Daily Life (SADL) questionnaire culturally adapted to Brazilian Portuguese. Results The quality of life of children using Auditory Brainstem Implant from the perspective of their parents showed global results above average, as for most domains, except for the emotional well-being domain. Adults showed results above average for all domains. Regarding satisfaction with the device, the adult users of auditory brainstem implant were satisfied in general, except with regard to personal image. The parents of the children showed dissatisfaction in all subscales, except for the subscale of services and cost. Conclusion The results indicated that although patients are dissatisfied with the device in some aspects, overall the quality of life was rated as good for most of the aspects assessed.
  • article 15 Citação(ões) na Scopus
    Cochlear Implantation Via the Middle Fossa Approach: Surgical and Programming Considerations
    (2012) BENTO, Ricardo Ferreira; BITTENCOURT, Aline Gomes; GOFFI-GOMEZ, Maria Valeria Schmidt; SAMUEL, Paola; TSUJI, Robinson Koji; BRITO, Rubens de
    Objectives: To report the results of cochlear implantation via the middle fossa approach in 4 patients, discuss the complications, and present a detailed description of the programming specifications in these cases. Study Design: Retrospective case review. Setting: Tertiary-care referral center with a well-established cochlear implant program. Patients: Four patients with bilateral canal wall down mastoid cavities who underwent the middle fossa approach for cochlear implantation. Interventions: Cochlear implantation and subsequent rehabilitation. A middle fossa approach with cochleostomy was successfully performed on the most superficial part of the apical turn in 4 patients. A Nucleus 24 cochlear implant system was used in 3 patients and a MED-EL Sonata Medium device in 1 patient. The single electrode array was inserted through a cochleostomy from the cochlear apex and occupied the apical, middle, and basal turns. Telemetry and intraoperative impedance recordings were performed at the end of surgery. A CT scan of the temporal bones was performed to document electrode insertion for all of the patients. Main Outcome Measures: Complications, hearing thresholds, and speech perception outcomes were evaluated. Results: Neural response telemetry showed present responses in all but 1 patient, who demonstrated facial nerve stimulation during the test. Open-set speech perception varied from 30% to 100%, despite the frequency allocation order of the MAP. Conclusion: Cochlear implantation via the middle cranial fossa is a safe approach, although it is a challenging procedure, even for experienced surgeons.
  • article 6 Citação(ões) na Scopus
    Speech perception in adolescents with pre-lingual hearing impairment with cochlear implants
    (2011) SOUZA, Izi Patricia Souza de; BRITO, Rubens de; BENTO, Ricardo Ferreira; GOMEZ, Maria Valeria S. Goffi; TSUJI, Robinson Koji; HAUSEN-PINNA, Mariana
    Profound hearing loss is a disability that affects personality and when it involves teenagers before language acquisition, these bio-psychosocial conflicts can be exacerbated, requiring careful evaluation and choice of them for cochlear implant. Aim: To evaluate speech perception by adolescents with profound hearing loss, users of cochlear Implants. Study Design: Prospective. Materials and Methods: Twenty-five individuals with severe or profound pre-lingual hearing loss who underwent cochlear implantation during adolescence, between 10 to 17 years and 11 months, who went through speech perception tests before the implant and 2 years after device activation. For comparison and analysis we used the results from tests of four choice, recognition of vowels and recognition of sentences in a closed setting and the open environment. Results: The average percentage of correct answers in the four choice test before the implant was 46.9% and after 24 months of device use, this value went up to 86.1% in the vowels recognition test, the average difference was 45.13% to 83.13% and the sentences recognition test together in closed and open settings was 19.3% to 60.6% and 1.08% to 20.47% respectively. Conclusion: All patients, although with mixed results, achieved statistical improvement in all speech tests that were employed.