MARIANNY NAZARETH SULBARAN NAVA

(Fonte: Lattes)
Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais

Resultados de Busca

Agora exibindo 1 - 8 de 8
  • conferenceObject
    KI-67 EXPRESSION CAN BE A MARKER OF AGRESSIVENESS OF DUODENAL DISEASE IN FAMILIAL ADENOMATOUS POLYPOSIS
    (2020) SULBARAN, Marianny; CAMPOS, Fabio G.; PAES, Vitor R.; ALVES, Venancio A.; KISHI, Humberto; MOURA, Eduardo G. de; BUSTAMANTE-LOPEZ, Leonardo A.; NAHAS, Sergio C.; RIBEIRO, Ulysses; COUDRY, Renata; SAFATLE, Adriana V.
  • article 0 Citação(ões) na Scopus
    ENDOSCOPIC GASTRIC SUBMUCOSAL DISSECTION: experimental comparative protocol between standard technique and Hybrid-Knife(r)
    (2016) MENDONÇA, Ernesto Quaresma; ZURETTI, Lucas Snioka; PANZANI, Thiago; SULBARAN, Marianny; SAKAI, Christiano Makoto; SAKAI, Paulo
    ABSTRACT Background Endoscopic treatment of superficial gastrointestinal tumors is routinely performed, however the advantages and shortcomings of submucosal pressure-jet dissection is still debated. Objective - Aiming to compare this technique with conventional submucosal dissection, a study was designed in pigs. Methods - Areas of the antral mucosa of the stomach with a diameter of 2 cm2 (6 per animal) were marked, and resected by means of the hybrid-knife (experimental technique), and Flush-knife or IT-knife (controls). An ERBE ICC 300 electrosurgical unit was adopted. End-points were procedural time, complications, and quality of the resected specimen. Results - A total of 27 interventions were conducted in five animals. Time spent with the two options was quite short, and similar: 9.5±3.1 vs 8.0±3.0 minutes (P=0.21). Complications didn't differ (three per group, not significant), and removed specimen looked adequate in both circumstances. Conclusion - The hybrid-knife technique is an acceptable alternative to submucosal dissection, showing no difference compared to the standard technique taking into consideration the procedure, the presence of complications and the quality of the resected specimen.
  • article 7 Citação(ões) na Scopus
    Systematic review and meta-analysis of colon capsule endoscopy accuracy for colorectal cancer screening. An alternative during the Covid-19 pandemic?
    (2022) SULBARAN, Marianny; BUSTAMANTE-LOPEZ, Leonardo; BERNARDO, Wanderley; SAKAI, Christiano M.; SAKAI, Paulo; NAHAS, Sergio; MOURA, Eduardo G. H. de
    Aim To determine the diagnostic accuracy of colon capsule endoscopy for colorectal cancer screening. Methods Studies that compared the diagnostic performance of colonoscopy and second-generation colon capsule endoscopy (CCE-2) for screening of asymptomatic patients aged 50-75 years were included. The primary outcomes were sensitivity, specificity, and positive and negative likelihood ratios for polyps and adenomas measuring at least 6 mm or 10 mm. Results Eight full-text studies that evaluated 1602 patients were included for systematic review. Of these, 840 (52.43%) patients participated in an opportunistic screening program. The pooled outcomes of CCE-2 for polyps at least 6 mm / 10 mm were (CI = confidence interval): sensitivity: 88% (95% CI: 0.84-0.91) / 88% (95% CI: 0.82-0.93), specificity: 94% (95% CI: 0.92-0.95) / 95.5% (95% CI: 0.94-0.97); positive likelihood ratio: 11.86 (95% CI: 5.53-25.46) / 23.07 (95% CI: 6.163-86.36); negative likelihood ratio: 0.14 (95% CI: 0.1-0.21) / 0.14 (95% CI: 0.09-0.21). The area under the summary receiver operating characteristic curve for polyps at least 6 and 10 mm was 96.3% and 96.7%, respectively. The only cancer missed by complete CCE-2 was shown at multiple frames in the unblinded review. In total, 125 (7.8%) patients presented mild adverse events mostly related to bowel preparation. Conclusion CCE-2 is demonstrated to be an effective and safe alternative method for colorectal cancer screening. Diagnostic performance of CCE-2 for polyps of at least 6 and 10 mm was similar. Completion rates still need to be improved.
  • article
    Overtube-assisted enteroscopy and capsule endoscopy for the diagnosis of small-bowel polyps and tumors: a systematic review and meta-analysis
    (2016) SULBARAN, Marianny; MOURA, Eduardo de; BERNARDO, Wanderley; MORAIS, Cintia; OLIVEIRA, Joel; BUSTAMANTE-LOPEZ, Leonardo; SAKAI, Paulo; MOENKEMUELLER, Klaus; SAFATLE-RIBEIRO, Adriana
    Background and study aims: Several studies have evaluated the utility of double-balloon enteroscopy (DBE) and capsule endoscopy (CE) for patients with small-bowel disease showing inconsistent results. The aim of this study was to determine the sensitivity and specificity of overtube-assisted enteroscopy (OAE) as well as the diagnostic concordance between OAE and CE for small-bowel polyps and tumors. Patients and methods: We conducted a systematic review and meta-analysis of studies in which the results of OAE were compared with the results of CE for the evaluation of small-bowel polyps and tumors. When data for surgically resected lesions were available, the histopathological results of OAE and surgical specimens were compared. The sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio for the diagnosis of small-bowel polyps and tumors were analyzed. Secondarily, the rates of diagnostic concordance and discordance between OAE and CE were calculated. Results: There were 15 full-length studies with a total of 821 patients that met the inclusion criteria. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were as follows: 0.89 (95% confidence interval [CI] 0.84-0.93), with heterogeneity chi(2)=41.23 (P = 0.0002) and inconsistency (I-2)=66.0 %; 0.97 (95 % CI 0.95-0.98), with heterogeneity chi(2)=45.27 (P=0.07) and inconsistency (I-2)=69.1 %; 16.61 (95 % CI 3.74-73.82), with heterogeneity Cochrane's Q=225.19 (P<0.01) and inconsistency (I-2)=93.8 %; and 0.14 (95 % CI 0.05-0.35), with heterogeneity Cochrane's Q=81.01 (P<.01) and inconsistency (I-2)=82.7 %, respectively. A summary receiver operating characteristic curve (SROC) curve was constructed, and the area under the curve (AUC) was 0.97. Conclusion: OAE is an accurate test for the detection of small-bowel polyps and tumors. OAE and CE have a high diagnostic concordance rate for small-bowel polyps and tumors. This study was registered in the PROSPERO international database (www.crd.york.ac.uk/prospero/) with the study number CRD42015016000.
  • conferenceObject
    SYSTEMATIC REVIEW AND META-ANALYSIS OF COLON CAPSULE ENDOSCOPY ACCURACY FOR COLORECTAL CANCER SCREENING. AN ALTERNATIVE DURING THE COVID ERA?
    (2021) SULBARAN, Marianny; BERNARDO, Wanderley M.; BUSTAMANTE-LOPEZ, Leonardo A.; SAKAI, Christiano M.; SAKAI, Paulo; NAHAS, Sergio C.; MOURA, Eduardo G. De
  • article 14 Citação(ões) na Scopus
    Upper gastrointestinal neoplasia in familial adenomatous polyposis: prevalence, endoscopic features and management
    (2019) CAMPOS, Fabio Guilherme; MARTINEZ, Augusto Real; SULBARAN, Marianny; BUSTAMANTE-LOPEZ, Leonardo Alfonso; SAFADE-RIBEIRO, Adriana Vaz
    Background: To evaluate the prevalence of upper gastrointestinal (GI) polyps in familial adenomatous polyposis (FAP), and to discuss current therapeutic recommendations. Methods: Clinical, endoscopic, histological and treatment data were retrieved from charts of 102 patients [1958-2016]. Duodenal adenomatosis was classified according to Spigelman stages. Results: this series comprised 59 women (57.8%) and 43 men (42.1%) with a median age of 32.3 years. Patients underwent 184 endoscopic procedures, the first at a median age of 35.9 years (range, 13-75 years). Fundic gastric polyps (n=31; 30.4%) prevailed in the stomach. While only 5 adenomas were found in the stomach, 33 patients (32.4%) presented duodenal ones. Advanced lesions (n=13; 12.7%) were detected in the stomach (n=2) and duodenum (n=11). During follow-up, Spigelman stages improved in 6 (12.2%) patients, remained unchanged in 25 (51.0%) and worsened in 18 (36.7%). Carcinomas were diagnosed in the stomach and duodenum (4 lesions each, 3.9%), at median ages of 50.2 and 55.0 years, respectively. Advanced lesions and carcinomas were managed through local or surgical resections. Severe complications occurred in only 2 patients (one death). Enteroscopy in 21 patients revealed jejunal adenomas in 12, 11 of whom also presented duodenal adenomas. Conclusions: There is a high prevalence of upper GI adenomas and cancer in FAP. There were diagnosed fundic gastric polyps (30.4%), duodenal (32.4%) and jejunal adenomas (11.8%), respectively. One third of duodenal polyps progressed slowly throughout the study. The rates of advanced gastroduodenal lesions (12.7%) and cancer (7.8%) raise the need for continuous surveillance during follow-up.
  • article 0 Citação(ões) na Scopus
    Endoscopic colostomy with percutaneous colopexy: an animal feasibility study
    (2017) BUSTAMANTE-LOPEZ, Leonardo Alfonso; SULBARAN, Marianny; NAHAS, Sergio Carlos; MOURA, Eduardo Guimaraes Horneaux de; NAHAS, Caio Sergio; MARQUES, Carlos Federico; SAKAI, Christiano; CECONELLO, Ivan; SAKAI, Paulo
    Background: Indications for colostomy in colorectal diseases are obstruction of the large bowel, such as in cancer, diverticular disease in the acute phase, post-radiotherapy enteritis, complex perirectal fistulas, anorectal trauma and severe anal incontinence. Some critically ill patients cannot tolerate an exploratory laparotomy, and laparoscopic assisted colostomy also requires general anesthesia. Objective: To evaluate the feasibility, safety and efficacy of performing colostomy assisted by colonoscopy and percutaneous colopexy. Materials and methods: Five pigs underwent endoscopic assisted colostomy with percutaneous colopexy. Animals were evaluated in post-operative days 1, 2, 5 and 7 for feeding acceptance and colostomy characteristics. On day 7 full colonoscopy was performed on animals followed by exploratory laparotomy. Results: Average procedure time was 27 minutes (2154 min). Postoperative mobility and feeding of animals were immediate after anesthesia recovery. Position of the colostomy, edges color, appearance of periostomal area, as well as its function was satisfactory in four animals. Retraction of colostomy was present in one pig. The colonoscopy and laparotomy control on the seventh day were considered as normal. A bladder perforation that was successfully repaired through the colostomy incision occurred in one pig. The main limitation of this study is its experimental nature. Conclusion: Endoscopic assisted colostomy with percutaneous colopexy proves to be a safe and effective method with low morbidity for performing colostomy in experimental animals, with possible clinical application in humans.
  • article
    Duodenal adenoma surveillance in patients with familial adenomatous polyposis
    (2015) CAMPOS, Fabio Guilherme; SULBARAN, Marianny; SAFATLE-RIBEIRO, Adriana Vaz; MARTINEZ, Carlos Augusto Real
    Familial adenomatous polyposis (FAP) is a hereditary disorder caused by Adenomatous Polyposis Gene mutations that lead to the development of colorectal polyps with great malignant risk throughout life. Moreover, numerous extracolonic manifestations incorporate different clinical features to produce varied individual phenotypes. Among them, the occurrence of duodenal adenomatous polyps is considered an almost inevitable event, and their incidence rates increase as a patient's age advances. Although the majority of patients exhibit different grades of duodenal adenomatosis as they age, only a small proportion (1%-5%) of patients will ultimately develop duodenal carcinoma. Within this context, the aim of the present study was to review the data regarding the epidemiology, classification, genetic features, endoscopic features, carcinogenesis, surveillance and management of duodenal polyps in patients with FAP.