ELIZABETH SARTORI CREVELARI

(Fonte: Lattes)
Índice h a partir de 2011
6
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina - Médico
LIM/11 - Laboratório de Cirurgia Cardiovascular e Fisiopatologia da Circulação, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 10 de 10
  • article 3 Citação(ões) na Scopus
    Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario
    (2020) COSTA, Roberto; SILVA, Katia Regina da; CREVELARI, Elizabeth Sartori; NASCIMENTO, Wagner Tadeu Jurevicius; NAGUMO, Marcia Mitie; MARTINELLI FILHO, Martino; JATENE, Fabio Biscegli
    Background: Transvenous lead extraction (TLE) of cardiac implantable electronic devices (CIED) is an uncommon procedure and requires specialized personnel and adequate facilities. Objectives: To evaluate the effectiveness and safety of the removal of CIED leads and to determine risk factors for surgical complications and mortality in 30 days. Methods: Prospective study with data derived from clinical practice. From January 2014 to April 2020, we included 365 consecutive patients who underwent TLE, regardless of the indication and surgical technique used. The primary outcomes were: success rate of the procedure, combined rate of major complications and intraoperative death. Secondary outcomes were: risk factors for major intraoperative complications and death within 30 days. Univariate and multivariate analysis were used, with a significance level of 5%. Results: Procedure success rate was 96.7%, with 90.1% of complete success and 6.6% of clinical success. Major intraoperative complications occurred in 15 (4.1%) patients. Predictors of major complications were: lead dwelling time >= 7 years (OR = 3.78, p = 0.046) and change in surgical strategy (OR = 5.30, p = 0.023). Functional class III-IV (OR = 6.98, p <0.001), renal failure (OR = 5.75, p = 0.001), CIED infection (OR = 13.30, p <0.001), number of procedures performed (OR = 77.32, p <0.001) and major intraoperative complications (OR = 38.84, p <0.001) were predictors of 30-day mortality. Conclusions: The results of this study, which is the largest prospective registry of consecutive TLE procedures in Latin America, confirm the safety and effectiveness of this procedure in the context of real clinical practice.
  • article 16 Citação(ões) na Scopus
    Effects of Cardiac Resynchronization Therapy on Muscle Sympathetic Nerve Activity
    (2014) KUNIYOSHI, Ricardo R.; MARTINELLI, Martino; NEGRAO, Carlos E.; SIQUEIRA, Sergio F.; RONDON, Maria U. P. B.; TROMBETTA, Ivani C.; KUNIYOSHI, Fatima H. S.; LATERZA, Mateus C.; NISHIOKA, Silvana A. D'Orio; COSTA, Roberto; TAMAKI, Wagner T.; CREVELARI, Elizabeth S.; PEIXOTO, Giselle De Lima; RAMIRES, Jose A. F.; KALIL, Roberto
    IntroductionMuscle sympathetic nerve activity (MSNA) is an independent prognostic marker in patients with heart failure (HF). Therefore, its relevance to the treatment of HF patients is unquestionable. ObjectivesIn this study, we investigated the effects of cardiac resynchronization therapy (CRT) on MSNA response at rest and during exercise in patients with advanced HF. MethodsWe assessed 11 HF patients (51 3.4 years; New York Heart Association class III-IV; left ventricular ejection fraction 27.8 2.2%; optimal medical therapy) submitted to CRT. Evaluations were made prior to and 3 months after CRT. MSNA was performed at rest and during moderate static exercise (handgrip). Peak oxygen consumption (VO2) was evaluated by means of cardiopulmonary exercise test. HF patients with advanced NYHA class without CRT and healthy individuals were also studied. ResultsCRT reduced MSNA at rest (48.9 +/- 11.1 bursts/min vs 33.7 +/- 15.3 bursts/min, P < 0.05) and during handgrip exercise (MSNA 62.3 +/- 13.1 bursts/min vs 46.9 +/- 14.3 bursts/min, P < 0.05). Among HF patients submitted to CRT, the peak VO2 increased (12.9 +/- 2.8 mL/kg/min vs 16.5 +/- 3.9 mL/kg/min, P < 0.05) and an inverse correlation between peak VO2 and resting MSNA (r = -0.74, P = 0.01) was observed. ConclusionsIn patients with advanced HF and severe systolic dysfunction: (1) a significant reduction of MSNA (at rest and during handgrip) occurred after CRT, and this behavior was significantly superior to HF patients receiving only medical therapy; (2) MSNA reduction after CRT had an inverse correlation with O-2 consumption outcomes.
  • article 12 Citação(ões) na Scopus
    Complications after Surgical Procedures in Patients with Cardiac Implantable Electronic Devices: Results of a Prospective Registry
    (2016) SILVA, Katia Regina da; ALBERTINI, Caio Marcos de Moraes; CREVELARI, Elizabeth Sartori; CARVALHO, Eduardo Infante Januzzi de; FIORELLI, Alfredo Inacio; MARTINELLI FILHO, Martino; COSTA, Roberto
    Background: Complications after surgical procedures in patients with cardiac implantable electronic devices (CIED) are an emerging problem due to an increasing number of such procedures and aging of the population, which consequently increases the frequency of comorbidities. Objective: To identify the rates of postoperative complications, mortality, and hospital readmissions, and evaluate the risk factors for the occurrence of these events. Methods: Prospective and unicentric study that included all individuals undergoing CIED surgical procedures from February to August 2011. The patients were distributed by type of procedure into the following groups: initial implantations (cohort 1), generator exchange (cohort 2), and lead-related procedures (cohort 3). The outcomes were evaluated by an independent committee. Univariate and multivariate analyses assessed the risk factors, and the Kaplan-Meier method was used for survival analysis. Results: A total of 713 patients were included in the study and distributed as follows: 333 in cohort 1, 304 in cohort 2, and 76 in cohort 3. Postoperative complications were detected in 7.5%, 1.6%, and 11.8% of the patients in cohorts 1, 2, and 3, respectively (p = 0.014). During a 6-month follow-up, there were 58 (8.1%) deaths and 75 (10.5%) hospital readmissions. Predictors of hospital readmission included the use of implantable cardioverter-defibrillators (odds ratio [OR] = 4.2), functional class III--IV (OR = 1.8), and warfarin administration (OR = 1.9). Predictors of mortality included age over 80 years (OR = 2.4), ventricular dysfunction (OR = 2.2), functional class III-IV (OR = 3.3), and warfarin administration (OR = 2.3). Conclusions: Postoperative complications, hospital readmissions, and deaths occurred frequently and were strongly related to the type of procedure performed, type of CIED, and severity of the patient's underlying heart disease.
  • article 6 Citação(ões) na Scopus
    Functional Capacity of Patients with Pacemaker Due to Isolated Congenital Atrioventricular Block
    (2015) OLIVEIRA JUNIOR, Roberto Marcio de; SILVA, Katia Regina da; KAWAUCHI, Tatiana Satie; ALVES, Lucas Bassolli de Oliveira; CREVELARI, Elizabeth Sartori; MARTINELLI FILHO, Martino; COSTA, Roberto
    Background: Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation. Objectives: To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling. Methods: This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%. Results: A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 +/- 6.3 years. The percentage of ventricular pacing was 97.9 +/- 4.1%, and the duration of the paced QRS complex was 153.7 +/- 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 +/- 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. Conclusions: The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling.
  • article 2 Citação(ões) na Scopus
    Impact of the COVID-19 Pandemic on Cardiac Implantable Electronic Devices Procedures in a Tertiary Referral Center
    (2021) COSTA, Roberto; SILVA, Katia Regina da; SAUCEDO, Sarah Caroline Martins; SILVA, Laisa Arruda; CREVELARI, Elizabeth Sartori; NASCIMENTO, Wagner Tadeu Jurevicius; SILVEIRA, Thiago Goncalves; FIORELLI, Alfredo; MARTINELLI FILHO, Martino; JATENE, Fabio Biscegli
  • article 0 Citação(ões) na Scopus
    Prognosis Determinants after Cardioverter-Defibrillators Implantation in Brazil Reply
    (2017) SILVA, Katia Regina da; ALBERTINI, Caio Marcos de Moraes; CREVELARI, Elizabeth Sartori; CARVALHO, Eduardo Infante Januzzi de; FIORELLI, Alfredo Inacio; MARTINELLI FILHO, Martino; COSTA, Roberto
  • article 4 Citação(ões) na Scopus
    Efficacy, Safety, and Performance of Isolated Left vs. Right Ventricular Pacing in Patients with Bradyarrhythmias: A Randomized Controlled Trial
    (2019) CREVELARI, Elizabeth Sartori; SILVA, Katia Regina da; ALBERTINI, Caio Marcos de Moraes; VIEIRA, Marcelo Luiz Campos; MARTINELLI FILHO, Martino; COSTA, Roberto
    Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring heart rate correction alone. Objective: To assess the safety, efficacy, and effects of LV pacing using an active-fixation coronary sinus lead in comparison with RV pacing, in patients eligible for conventional pacemaker (PM) implantation. Methods: Randomized, controlled, and single-blinded clinical trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs. LV) occurred before PM implantation. The main results of the study were procedural success, safety, and efficacy. Secondary results were clinical and echocardiographic changes. Chi-squared test, Fisher's exact test and Student's t-test were used, considering a significance level of 5%. Results: From June 2012 to January 2014, 91 patients were included, 36 in the RV Group and 55 in the LV Group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated into the LV group, active-fixation coronary sinus lead implantation was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations due to heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and 20.6% of those in the LV group (p = 0.767). Tissue Doppler analysis showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (p = 0.022). Conclusion: The procedural success rate of LV implant was low, and the safety of the procedure was influenced mainly by the high rate of phrenic nerve stimulation in the postoperative period.
  • conferenceObject
    Incidence of pulmonary embolism and upper-extremity deep venous thrombosis in patients submitted to lead extraction and upgrade procedures
    (2016) ALBERTINI, C. M. M.; SILVA, K. R.; AMAYA, I. C. M.; MELO, G. R. G.; CREVELARI, E. S.; LEAL, J. M. M.; LIMA, M. F.; CHATE, R. C.; HIGA, K.; NOMURA, C.; MARTINELLI FILHO, M.; COSTA, R.
  • article 7 Citação(ões) na Scopus
    Quality of Life and Functional Capacity after Long-Term Right Ventricular Pacing in Pediatrics and Young Adults with Congenital Atrioventricular Block
    (2013) SILVA, Katia Regina da; COSTA, Roberto; OLIVEIRA JR., Roberto Marcio De; LACERDA, Marianna Sobral; HUANG, Adriana I. Un; ROSSI, Marina Bertelli; CREVELARI, Elizabeth Sartori; TAMAKI, Wagner Tetsuji; MARTINELLI FILHO, Martino; PIETROBON, Ricardo
    BackgroundAlthough several studies have demonstrated deleterious consequences of chronic right ventricular (RV) pacing on ventricular function and synchronicity, its effects on health-related quality of life (HRQoL) and functional exercise capacity remain uncertain. We aimed to evaluate the effect of RV pacing on HRQoL and functional capacity of children and young adults with congenital complete atrioventricular block (CCAVB). MethodsWe included 66 consecutive subjects with RV cardiac pacemaker due to CCAVB and under clinical follow-up for more than 1 year. Multidimensional HRQoL scores were evaluated by Short Form-36 Health Survey (SF-36) and Child Health Questionnaire-Parent Form 50 (CHQ-PF50). Functional capacity was tested by a 6-minute walk distance test (6MWDT). Association analysis was performed to examine if any demographic and clinical characteristics were associated with lower HRQoL scores and shorter distances at the 6MWDT. ResultsDomains presenting lower HRQoL scores were vitality (64.0 17.3), mental health (67.3 +/- 8.0), role emotional (69.7 +/- 35.8) in the SF-36 questionnaire; general health perceptions (61.3 +/- 8.3), general behavior (61.9 +/- 15.6), parental impactemotional (67.7 +/- 28.7) in the CHQ-PF50. Female gender (P = 0.009), left ventricular ejection fraction lower than 55% (P = 0.013), cardiovascular drugs (P = 0.003) were significantly associated with lower HRQoL scores. Average distance traveled during the 6MWDT was 539.8 +/- 82.9 m. The 6MWDT showed significant association with age (P = 0.006) and cardiovascular drugs (P = 0.024). ConclusionsChronic RV pacing did not affect the HRQoL and physical capacity of pediatrics and young subjects. Female gender, ventricular function, and cardiovascular drugs were associated with lower HRQoL scores. Older subjects walked shorter distances in the 6MWDT, as well as subjects who were taking cardiovascular drugs.
  • article 13 Citação(ões) na Scopus
    Usefulness of Preoperative Venography in Patients with Cardiac Implantable Electronic Devices Submitted to Lead Replacement or Device Upgrade Procedures
    (2018) ALBERTINI, Caio Marcos de Moraes; SILVA, Katia Regina da; LEAL FILHO, Joaquim Maurfcio da Motta; CREVELARI, Elizabeth Sartori; MARTINELLI FILHO, Martino; CAMEVALE, Francisco Cesar; COSTA, Roberto
    Background: Venous obstructions are common in patients with transvenous cardiac implantable electronic devices, but they rarely cause immediate clinical problems. The main consequence of these lesions is the difficulty in obtaining venous access for additional leads implantation. Objectives: We aimed to assess the prevalence and predictor factors of venous lesions in patients referred to lead reoperations, and to define the role of preoperative venography in the planning of these procedures. Methods: From April 2013 to July 2016, contrast venography was performed in 100 patients referred to device upgrade, revision and lead extraction. Venous lesions were classified as non-significant (< 50%), moderate stenosis (51-70%), severe stenosis (71-99%) or occlusion (100%). Collateral circulation was classified as absent, discrete, moderate or accentuated. The surgical strategy was defined according to the result of the preoperative venography. Univariate analysis was used to investigate predictor factors related to the occurrence of these lesions, with 5% of significance level. Results: Moderate venous stenosis was observed in 23%, severe in 13% and occlusions in 11%. There were no significant differences in relation to the device side or the venous segment. The usefulness of the preoperative venography to define the operative tactic was proven, and in 99% of the cases, the established surgical strategy could be performed according to plan. Conclusions: The prevalence of venous obstruction is high in CIED recipients referred to reoperations. Venography is highly indicated as a preoperative examination for allowing the adequate surgical planning of procedures involving previous transvenous leads.