WAGNER TADEU JUREVICIUS DO NASCIMENTO

Índice h a partir de 2011
2
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina - Médico

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • article 3 Citação(ões) na Scopus
    Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario
    (2020) COSTA, Roberto; SILVA, Katia Regina da; CREVELARI, Elizabeth Sartori; NASCIMENTO, Wagner Tadeu Jurevicius; NAGUMO, Marcia Mitie; MARTINELLI FILHO, Martino; JATENE, Fabio Biscegli
    Background: Transvenous lead extraction (TLE) of cardiac implantable electronic devices (CIED) is an uncommon procedure and requires specialized personnel and adequate facilities. Objectives: To evaluate the effectiveness and safety of the removal of CIED leads and to determine risk factors for surgical complications and mortality in 30 days. Methods: Prospective study with data derived from clinical practice. From January 2014 to April 2020, we included 365 consecutive patients who underwent TLE, regardless of the indication and surgical technique used. The primary outcomes were: success rate of the procedure, combined rate of major complications and intraoperative death. Secondary outcomes were: risk factors for major intraoperative complications and death within 30 days. Univariate and multivariate analysis were used, with a significance level of 5%. Results: Procedure success rate was 96.7%, with 90.1% of complete success and 6.6% of clinical success. Major intraoperative complications occurred in 15 (4.1%) patients. Predictors of major complications were: lead dwelling time >= 7 years (OR = 3.78, p = 0.046) and change in surgical strategy (OR = 5.30, p = 0.023). Functional class III-IV (OR = 6.98, p <0.001), renal failure (OR = 5.75, p = 0.001), CIED infection (OR = 13.30, p <0.001), number of procedures performed (OR = 77.32, p <0.001) and major intraoperative complications (OR = 38.84, p <0.001) were predictors of 30-day mortality. Conclusions: The results of this study, which is the largest prospective registry of consecutive TLE procedures in Latin America, confirm the safety and effectiveness of this procedure in the context of real clinical practice.
  • article 2 Citação(ões) na Scopus
    Impact of the COVID-19 Pandemic on Cardiac Implantable Electronic Devices Procedures in a Tertiary Referral Center
    (2021) COSTA, Roberto; SILVA, Katia Regina da; SAUCEDO, Sarah Caroline Martins; SILVA, Laisa Arruda; CREVELARI, Elizabeth Sartori; NASCIMENTO, Wagner Tadeu Jurevicius; SILVEIRA, Thiago Goncalves; FIORELLI, Alfredo; MARTINELLI FILHO, Martino; JATENE, Fabio Biscegli