CARLOS ALBERTO BUCHPIGUEL

(Fonte: Lattes)
Índice h a partir de 2011
28
Projetos de Pesquisa
Unidades Organizacionais
Departamento de Radiologia, Faculdade de Medicina - Docente
LIM/43 - Laboratório de Medicina Nuclear, Hospital das Clínicas, Faculdade de Medicina - Líder

Resultados de Busca

Agora exibindo 1 - 10 de 15
  • article 0 Citação(ões) na Scopus
    A medicina nuclear no Sistema Único de Saúde no Brasil
    (2014) BUCHPIGUEL, Carlos Alberto
  • article 2 Citação(ões) na Scopus
    Prevalence of exclusive lower extremity metastases at 18F-NaF PET/CT
    (2015) ORDONES, Monique Beraldo; VALADARES, Agnes Araujo; DUARTE, Paulo Schiavom; SADO, Heitor Naoki; LIMA, Marcos Santos; CARVALHO, Giovanna; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To evaluate the prevalence of exclusive lower extremity metastases, specifically in the femur and below the knee, observed at 18F-NaF PET/CT. Materials and Methods: One thousand consecutive PET/CT studies were retrospectively evaluated for the presence of exclusive uptake in lower extremities suggesting metastatic involvement. The presumptive diagnoses based on such uptakes were subsequently obtained by evaluation of other imaging studies. Results: No exclusive uptake suggestive of metastasis below the femur was observed in the present series. Exclusive uptake was observed in the proximal femur with a presumptive diagnosis of metastasis in two patients. Conclusion: The prevalence of exclusive metastasis below the femur is low and scanning from head to knees is appropriate in most cases.
  • article 6 Citação(ões) na Scopus
    Estimating 131I biokinetics and radiation doses to the red marrow and whole body in thyroid cancer patients: probe detection versus image quantification
    (2016) WILLEGAIGNON, José; PELISSONI, Rogério Alexandre; LIMA, Beatriz Christine de Godoy Diniz; SAPIENZA, Marcelo Tatit; COURA-FILHO, George Barberio; QUEIROZ, Marcelo Araújo; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To compare the probe detection method with the image quantification method when estimating 131I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients. Materials and Methods: Fourteen patients with metastatic thyroid cancer, without metastatic bone involvement, were submitted to therapy planning in order to tailor the therapeutic amount of 131I to each individual. Whole-body scans and probe measurements were performed at 4, 24, 48, 72, and 96 h after 131I administration in order to estimate the effective half-life (Teff) and residence time of 131I in the body. Results: The mean values for Teff and residence time, respectively, were 19 ± 9 h and 28 ± 12 h for probe detection, compared with 20 ± 13 h and 29 ± 18 h for image quantification. The average dose to the red marrow and whole body, respectively, was 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq for probe detection, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq for image quantification. Statistical analysis proved that there were no significant differences between the two methods for estimating the Teff (p = 0.801), residence time (p = 0.801), dose to the red marrow (p = 0.708), and dose to the whole body (p = 0.811), even when we considered an optimized approach for calculating doses only at 4 h and 96 h after 131I administration (p > 0.914). Conclusion: There is full agreement as to the feasibility of using probe detection and image quantification when estimating 131I biokinetics and red-marrow/whole-body doses. However, because the probe detection method is inefficacious in identifying tumor sites and critical organs during radionuclide therapy and therefore liable to skew adjustment of the amount of 131I to be administered to patients under such therapy, it should be used with caution.
  • article 6 Citação(ões) na Scopus
    Complementary findings on 18F-FDG PET/CT and 18F-NaF PET/CT in a patient with Erdheim-Chester disease
    (2017) SABINO, Daniela; VALE, Romulo Hermeto Bueno do; DUARTE, Paulo Schiavom; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
  • article 3 Citação(ões) na Scopus
    18F-FDG-PET/CT-measured parameters as potential predictors of residual disease after neoadjuvant chemoradiotherapy in patients with esophageal carcinoma
    (2022) TUSTUMI, Francisco; ALBENDA, David Gutiérrez; SALLUM, Rubens Antonio Aissar; NAHAS, Sergio Carlos; RIBEIRO JUNIOR, Ulysses; BUCHPIGUEL, Carlos Alberto; CECCONELLO, Ivan; DUARTE, Paulo Schiavom
    Abstract Objective: To evaluate the maximum and mean standardized uptake values, together with the metabolic tumor value and the total lesion glycolysis, at the primary tumor site, as determined by 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG-PET/CT), performed before and after neoadjuvant chemoradiotherapy (nCRT), as predictors of residual disease (RD) in patients with esophageal cancer. Materials and Methods: The standardized uptake values and the volumetric parameters (metabolic tumor value and total lesion glycolysis) were determined by 18F-FDG-PET/CT to identify RD in 39 patients before and after nCRT for esophageal carcinoma. We used receiver operating characteristic curves to analyze the diagnostic performance of 18F-FDG-PET/CT parameters in the definition of RD. The standard of reference was histopathological analysis of the surgical specimen. Results: Eighteen patients (46%) presented RD after nCRT. Statistically significant areas under the curve (approximately 0.72) for predicting RD were obtained for all four of the variables evaluated after nCRT. Considering the presence of visually detectable uptake (higher than the background level) at the primary tumor site after nCRT as a positive result, we achieved a sensitivity of 94% and a specificity of 48% for the detection of RD. Conclusion: The use of 18F-FDG-PET/CT can facilitate the detection of RD after nCRT in patients with esophageal cancer.
  • article 1 Citação(ões) na Scopus
    Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
    (2015) VALADARES, Agnes Araujo; DUARTE, Paulo Schiavom; WOELLNER, Eduardo Bechtloff; COURA-FILHO, George Barberio; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Objective: To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on 18FNaF PET/CT scans. Materials and Methods: A total of 254 18F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses covered 675 regions classified as normal (236 RH, 232 RF, and 207 LV1). Results: Mean SUV for each skeletal region was 3.8, 5.4 and 14.4 for RH, RF, and LV1, respectively. As the studies were grouped according to mAs value, the mean SUV values were 3.8, 3.9 and 3.7 for 10, 20 and 30 mAs, respectively, in the RH region; 5.4, 5.5 and 5.4 for 10, 20 and 30 mAs, respectively, in the RF region; 13.8, 14.9 and 14.5 for 10, 20 and 30 mAs, respectively, in the LV1 region. Conclusion: The three tube current values yielded similar results for SUV calculation.
  • article 5 Citação(ões) na Scopus
    Bone marrow uptake of 18F-fluorodeoxyglucose in Hodgkin lymphoma without bone involvement: comparison between patients with and without B symptoms
    (2018) VALE, Rômulo Hermeto Bueno do; FERRARO, Daniela Andrade; DUARTE, Paulo Schiavom; CARVALHO, Giovana; LIMA, Marcos Santos; COURA FILHO, George Barbério; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To compare the degree of benign bone marrow uptake of 18F-fluorodeoxyglucose (18F-FDG) between Hodgkin lymphoma patients with and without B symptoms. Materials and Methods: We analyzed the medical charts of 74 Hodgkin lymphoma patients who underwent 18F-FDG positron emission tomography/computed tomography (PET/CT) prior to the initiation of therapy between October 2010 and September 2013. In all of the patients, the bone marrow biopsy was negative and the 18F-FDG PET/CT images did not suggest bone marrow involvement. Of the 74 patients evaluated, 54 presented inflammatory (B) symptoms and 20 did not. Regions of interest (ROIs) were drawn on the sternum, the proximal thirds of the humeri, the proximal thirds of the femora, and both iliac wings (totaling seven ROIs per patient). To compare the patients with and without B symptoms, in terms of standardized uptake values (SUVs) for the seven ROIs, we used the Mann-Whitney U test. Results: For six of the ROIs, the SUVs were higher in the patients with B symptoms than in those without, and the difference was statistically significant (p < 0.05). There was also a tendency toward a statistically significant difference between the two groups in terms of the SUV for the right iliac wing ROI (p = 0.06). Conclusion: In our sample, the presence of B symptoms was associated with increased 18F-FDG uptake in bone marrow.
  • article 1 Citação(ões) na Scopus
    Validation of automated image co-registration integrated into in-house software for voxel-based internal dosimetry on single-photon emission computed tomography images
    (2023) LEITÃO, André Luiz Alberti; FONDA, Uysha de Souza; BUCHPIGUEL, Carlos Alberto; WILLEGAIGNON, José; SAPIENZA, Marcelo Tatit
    Abstract Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in relation to the bed axis), with and without a fiducial marker. Two rigid co-registration software packages-SPM12 and NMDose-coreg-were employed, and the percent root mean square error (%RMSE) was calculated in order to assess the quality of the co-registrations. Uniformity, contrast, and resolution were measured before and after co-registration. The NMDose-coreg software was employed to calculate the renal doses in 12 patients treated with 177Lu-DOTATATE, and we compared those with the values obtained with the Organ Level INternal Dose Assessment for EXponential Modeling (OLINDA/EXM) software. Results: The use of a fiducial marker had no significant effect on the quality of co-registration on SPECT images, as measured by %RMSE (p = 0.40). After co-registration, uniformity, contrast, and resolution did not differ between the images acquired with fiducial markers and those acquired without. Preliminary clinical application showed mean total processing times of 9 ± 3 min/patient for NMDose-coreg and 64 ± 10 min/patient for OLINDA/EXM, with a strong correlation between the two, despite the lower renal doses obtained with NMDose-coreg. Conclusion: The use of NMDose-coreg allows fast co-registration of SPECT images, with no loss of uniformity, contrast, or resolution. The use of a fiducial marker does not appear to increase the accuracy of co-registration on phantoms.
  • article 0 Citação(ões) na Scopus
  • article 2 Citação(ões) na Scopus
    Radiation safety measures in diagnostic nuclear medicine, based on the potential radiation dose emitted by radioactive patients
    (2023) WILLEGAIGNON, José; FERNANDES, Samantha Cristina Pereira; PELISSONI, Rogério Alexandre; COURA-FILHO, George Barbério; SAPIENZA, Marcelo Tatit; BUCHPIGUEL, Carlos Alberto
    Abstract Objective: To measure the potential radiation dose emitted by patients who have recently undergone diagnostic nuclear medicine procedures, in order to establish optimal radiation safety measures for such procedures. Materials and Methods: We evaluated the radiation doses emitted by 175 adult patients in whom technetium-99m, iodine-131, and fluorine-18 radionuclides were administered for bone, kidney, heart, brain, and whole-body scans, as measured with a radiation detector. Those values served as the basis for evaluating whole-body radiopharmaceutical clearance, as well as the risk for the exposure of others to radiation, depending on the time elapsed since administration of the radiopharmaceutical. Results: The mean time to clearance of the radiopharmaceuticals administered, expressed as the effective half-life, ranged from 1.18 ± 0.30 h to 11.41 ± 0.02 h, and the mean maximum cumulative radiation dose at 1.0 m from the patients was 149.74 ± 56.72 µSv. Even at a distance of 0.5 m, the cumulative dose was found to be only half and one tenth of the limits established for exposure of the general public and family members/caregivers (1.0 mSv and 5.0 mSv per episode, respectively). Conclusion: Cumulative radiation doses emitted by patients immediately after diagnostic nuclear medicine procedures are considerably lower than the limits established by the International Commission on Radiological Protection and the International Atomic Energy Agency, and precautionary measures to avoid radiation exposure are therefore not required after such procedures.