CARLO CAMARGO PASSEROTTI

(Fonte: Lattes)
Índice h a partir de 2011
12
Projetos de Pesquisa
Unidades Organizacionais
LIM/55 - Laboratório de Urologia, Hospital das Clínicas, Faculdade de Medicina - Líder

Resultados de Busca

Agora exibindo 1 - 10 de 12
  • article 14 Citação(ões) na Scopus
    Surgical Performance During Laparoscopic Radical Nephrectomy Is Improved With Training in a Porcine Model
    (2012) CRUZ, Jose Arnaldo Shiomi da; PASSEROTTI, Carlo Camargo; FRATI, Rodrigo Marcus Cunha; REIS, Sabrina Thalita dos; OKANO, Marcelo Takeo Rufato; GOUVEIA, Eder Maxwell; BIOLO, Karlo Domelles; DUARTE, Ricardo Jordao; Hiep Nguyen; SROUGI, Miguel
    Background and Purpose: Becoming proficient in laparoscopic surgery is dependent on the acquisition of specialized skills that can only be obtained from specific training. This training could be achieved in various ways using inanimate models, animal models, or live patient surgery-each with its own pros and cons. Currently, there are substantial data that support the benefits of animal model training in the initial learning of laparoscopy. Nevertheless, whether these benefits extent themselves to moderately experienced surgeons is uncertain. The purpose of this study was to determine if training using a porcine model results in a quantifiable gain in laparoscopic skills for moderately experienced laparoscopic surgeons. Materials and Methods: Six urologists with some laparoscopic experience were asked to perform a radical nephrectomy weekly for 10 weeks in a porcine model. The procedures were recorded, and surgical performance was assessed by two experienced laparoscopic surgeons using a previously published surgical performance assessment tool. The obtained data were then submitted to statistical analysis. Results: With training, blood loss was reduced approximately 45% when comparing the averages of the first and last surgical procedures (P = 0.006). Depth perception showed an improvement close to 35% (P = 0.041), and dexterity showed an improvement close to 25% (P = 0.011). Total operative time showed trends of improvement, although it was not significant (P = 0.158). Autonomy, efficiency, and tissue handling were the only aspects that did not show any noteworthy change (P = 0.202, P = 0.677, and P = 0.456, respectively). Conclusions: These findings suggest that there are quantifiable gains in laparoscopic skills obtained from training in an animal model. Our results suggest that these benefits also extend to more advanced stages of the learning curve, but it is unclear how far along the learning curve training with animal models provides a clear benefit for the performance of laparoscopic procedures. Future studies are necessary to confirm these findings and better understand the impact of this learning tool on surgical practice.
  • article 1 Citação(ões) na Scopus
    Assessment of a new kind of surgical simulator. The physical surgical simulator
    (2018) CRUZ, Jose Arnaldo Shiomi da; MIRANDA, Andre Filipe; COSTA, Lucas Evangelista da; AZEVEDO, Rafael Ulysses de; REIS, Sabrina Thalita dos; SROUGI, Miguel; PASSEROTTI, Carlo Camargo
    Purpose: To evaluate whether the use of the physical surgical simulator may benefit the development of laparoscopic skills. Methods: Ten medical students were divided into two groups: the first one performed ten weekly training sessions with a physical surgical simulator - ETX A2 LAP and, afterwards, one laparoscopic cholecystectomy in a porcine model, while the second group performed only a laparoscopic cholecystectomy. Both groups were compared regarding bleeding, total surgical time, time to perform each surgical step and qualitative parameters, based on a previously validated tool. Results: There was no difference in any of the evaluated parameters. Conclusion: We did not find any evidence of benefit in the use of the physical simulator for surgical performance in medical students.
  • article 27 Citação(ões) na Scopus
    MMP-9 overexpression due to TIMP-1 and RECK underexpression is associated with prognosis in prostate cancer
    (2011) REIS, Sabrina Thalita; PONTES-JUNIOR, Jose; ANTUNES, Alberto Azoubel; SOUSA-CANAVEZ, Juliana Moreira de; DALL'OGLIO, Marcos Francisco; PASSEROTTI, Carlo C.; ABE, Daniel Kanda; CRIPPA, Alexandre; CRUZ, Jose Arnaldo Shiomi da; TIMOSZCZUK, Luciana M. S.; SROUGI, Miguel; LEITE, Katia R. M.
    Background: Extracellular matrix homeostasis is strictly maintained by a coordinated balance between the expression of metalloproteinases (MMPs) and their inhibitors. The purpose of this study was to investigate whether the expression of MMP-9 and its specific inhibitors, TIMP-1 and RECK, are expressed in a reproducible, specific pattern and if the profiles are related to prognosis and clinical outcome in prostate cancer (PC). Methods: MMP-9, TIMP-1, and RECK expression levels were analyzed by quantitative real-time polymerase chain reaction (qRT-PCR) in fresh-frozen malignant tissue specimens collected from 79 patients with clinically localized PC submitted to radical prostatectorny (RP). Frozen benign prostatic tissue from another 10 men with prostate cancer, also submitted to RP, was analyzed to determine if the profile of gene expression was maintained. The control group consisted of 11 patients with benign prostate hyperplasia (BPH). Results: In the tumor samples, MMP-9 was overexpressed by 9.2 times, and TIMP-1 and RECK were underexpressed (0.75 and 0.80 times, respectively). Overexpression of MMP-9 was significantly related to PSA levels above 10 ng/mL (p=0.033). In addition, MMP-9 overexpression was related to biochemical recurrence, with a marginal statistical significance (p=0.089). MMP-9 was also overexpressed in benign tissues of patients with PC, as were TIMP-1 and RECK, in contrast to their underexpression in tumor samples. Conclusion: Our results show that MMP-9 is overexpressed and its negative regulators are underexpressed in PC tissue, emphasizing a possible role of MMP-9 in the carcinogenesis process. Additionally, we noticed a relationship between MMP-9 overexpression and increased levels of PSA, an important prognostic factor. In benign tissue adjacent to tumors, the MMP-9 equilibrium is likely maintained because the expression of its negative regulators is preserved.
  • article 69 Citação(ões) na Scopus
    Tgf-beta 1 expression as a biomarker of poor prognosis in prostate cancer
    (2011) REIS, Sabrina Thalita dos; PONTES-JUNIOR, Jose; ANTUNES, Alberto Azoubel; SOUSA-CANAVEZ, Juliana Moreira de; ABE, Daniel Kanda; CRUZ, Jose Arnaldo Shiomi da; DALL'OGLIO, Marcos Francisco; CRIPPA, Alexandre; PASSEROTTI, Carlo Camargo; RIBEIRO-FILHO, Leopoldo A.; VIANA, Nayara Izabel; SROUGI, Miguel; LEITE, Katia Ramos Moreira
    OBJECTIVE: To evaluate the correlation between transforming growth factor beta (TGF-beta 1) expression and prognosis in prostate cancer. PATIENTS AND METHODS: TGF-beta 1 expression levels were analyzed using the quantitative real-time polymerase chain reaction to amplify RNA that had been isolated from fresh-frozen malignant and benign tissue specimens collected from 89 patients who had clinically localized prostate cancer and had been treated with radical prostatectomy. The control group consisted of 11 patients with benign prostate hyperplasia. The expression levels of TGF-beta 1 were compared between the groups in terms of Gleason scores, pathological staging, and prostate-specific antigen serum levels. RESULTS: In the majority of the tumor samples, TGF-beta 1 was underexpressed 67.0% of PCa patients. The same expression pattern was identified in benign tissues of patients with prostate cancer. Although most cases exhibited underexpression of TGF-beta 1, a higher expression level was found in patients with Gleason scores >= 7 when compared to patients with Gleason scores <7 (p = 0.002). Among the 26 cases of TGF-beta 1 overexpression, 92.3% had poor prognostic features. CONCLUSIONS: TGF-beta 1 was underexpressed in prostate cancers; however, higher expression was observed in tumors with higher Gleason scores, which suggests that TGF-beta 1 expression may be a useful prognostic marker for prostate cancer. Further studies of clinical specimens are needed to clarify the role of TGF-beta 1 in prostate carcinogenesis.
  • article 28 Citação(ões) na Scopus
    Bladder exstrophy: reconstructed female patients achieving normal pregnancy and delivering normal babies
    (2011) GIRON, Amilcar Martins; PASSEROTTI, Carlo Camargo; Hiep Nguyen; CRUZ, Jose Arnaldo Shiomi da; SROUGI, Miguel
    Purpose: Bladder exstrophy (BE) is an anterior midline defect that causes a series of genitourinary and muscular malformations, which demands surgical intervention for correction. Women with BE are fertile and able to have children without this disease. The purpose of this study is to assess the sexual function and quality of life of women treated for BE. Materials and Methods: All patients in our institution treated for BE from 1987 to 2007 were recruited to answer a questionnaire about their quality of life and pregnancies. Results: Fourteen women were submitted to surgical treatment for BE and had 22 pregnancies during the studied period. From those, 17 pregnancies (77.2%) resulted in healthy babies, while four patients (18.1%) had a spontaneous abortion due to genital prolapse, and there was one case (4.7%) of death due to a pneumopathy one week after delivery. There was also one case (5.8%) of premature birth without greater repercussions. During pregnancy, three patients (21.4%) had urinary tract infections and one patient (7.14%) presented urinary retention. After delivery, three patients (21.4%) presented temporary urinary incontinence; one patient (7.14%) had a vesicocutaneous fistula and seven patients (50%) had genital prolapsed. All patients confirmed to have achieved urinary continence, a regular sexual life and normal pregnancies. All patients got married and pregnant older than the general population. Conclusions: BE is a severe condition that demands medical and family assistance. Nevertheless, it is possible for the bearers of this condition to have a satisfactory and productive lifestyle.
  • article 36 Citação(ões) na Scopus
    Does Warm-Up Training in a Virtual Reality Simulator Improve Surgical Performance? A Prospective Randomized Analysis
    (2016) CRUZ, Jose Arnaldo Shiomi da; REIS, Sabrina Thalita dos; FRATI, Rodrigo Marcus Cunha; DUARTE, Ricardo Jordao; Hiep Nguyen; SROUGI, Miguel; PASSEROTTI, Carlo Camargo
    INTRODUCTION: Virtual reality surgical simulators (VRSS) have been showing themselves as a valuable tool in laparoscopy training and education. Taking in consideration the effectiveness of the VRSS, new uses for this tool have been purposed. In sports, warming up before exercise clearly shows benefit in performance. It is hypothesized that warming up in the VRSS before going to the operating room may show benefit in surgical performance. OBJECTIVE: Verify whether there is benefit in surgical performance with preoperatory warm-up using a VRSS. MATERIALS AND METHODS: A total of 20 medical students with basic knowledge in laparoscopy were divided in 2 groups (I and II). Group I performed a laparoscopic cholecystectomy in a porcine model. Group II performed preoperative warm-up in a VRSS and then performed a laparoscopic cholecystectomy in a porcine model. The performance between both groups was compared regarding quantitative parameters (time for dissection of the gallbladder pedicle, time for clipping the pedicle, time for cutting the pedicle, time for gallbladder removal, total operative time, and aspirated blood loss) and qualitative parameters (depth perception, bimanual dexterity, efficiency, tissue handling, and autonomy) based on a previously validated score system, in which the higher the score, the better the result. Data were analyzed with level of significance of 5%. RESULTS: The group that underwent preoperative warm-up (group II) showed significantly superior results as to the time for dissection of the gallbladder pedicle (11.91 +/- 9.85 vs. 4.52 +/- 2.89 min, p = 0.012), time for clipping the pedicle (5.51 2.36 vs. 2.89 +/- 2.76 min, p = 0.004), time for cutting the pedide (1.84 +/- 0.7 vs. 1.13 +/- 0.51, p = 0.019), aspirated blood loss (171 +/- 112 vs. 57 +/- 27.8 ml, p = 0.006), depth perception (4.5 +/- 0.7 vs. 3.3 +/- 0.67, p = 0.004), bianual dexterity (4.2 +/- 0.78 vs. 3.3 +/- 0.67, p = 0.004), tissue handling (4.2 +/- 0.91 vs. 3.6 +/- 0.66, p = 0.012), and autonomy (4.9 +/- 0.31 vs. 3.6 +/- 0.96, p = 0.028). There was no difference in time for gallbladder removal (11.58 +/- 4.31 vs. 15.08 +/- 4.51 min, p = 0.096), total operative time (30.8 +/- 11.07 vs. 25.60 +/- 5.10 min, p = 0.188), and efficiency (4 0.66 vs. 3.6 +/- 0.69, p = 0.320). CONCLUSION: The practice of preoperative warm-up training seems to benefit surgical performance even in subject with mild laparoscopic experience.
  • article 9 Citação(ões) na Scopus
    Digital application developed to evaluate functional results following robot-assisted radical prostatectomy* App for prostate cancer
    (2020) FARIA, Leandro F.; REIS, Sabrina T.; LEITE, Katia R.; CRUZ, Jose Arnaldo Shiomi da; PIMENTA, Ruan; I, Nayara Viana; AMARAL, Gabriela Q.; SANTOS, Gabriel A. G. D.; ILIAS, Daniel; FAKHOURI, Felipe; XAVIER, Geraldo; SROUGI, Miguel; PASSEROTTI, Carlo Camargo
    Introduction: Mobile applications (""apps"") developed for smartphones and tablets are increasingly used in healthcare, allowing remote patient support or promoting self-health care. Prostate cancer (PC) screening allows for early-stage PC diagnosis, resulting in high rates of curative procedures such as radical prostatectomy. The main complications following surgery are urinary incontinence and erectile dysfunction. However, the exact numbers related to these morbidities are often missing due to brief interviews during consultations in the medical office. Therefore, the aim of this study was to create an app to determine whether response rates to preand post-surgical PC questionnaires will increase. Methods: The app was built using the IONIC framework system and provided to patients through a prospective randomized study. We included 100 patients divided into two groups: 1. first group used the app (n = 50); and 2. second group responded via validated printed questionnaires (control group) (n = 50). All patients received discharge counseling to respond to the questionnaires 1, 3, 6 and 12 months after the procedure. The app group received verbal guidance on how monitoring would occur, received an SMS containing a username and password providing access to the system and received reminder alerts to respond to the questionnaires. Results: The new app is called UroHealth and is available for download in the Apple App Store or at www.urohealth.com.br . When we evaluated the response rates, we found that 42.9% of the patients answered the preoperative questionnaire in the app group, while 16% responded in the control group (p = 0.003). By the end of the follow-up, we found that 24.5% of the patients answered the questionnaire in the app group, while 4% responded in the control group (p = 0.003). Conclusion: This app enabled almost 6 times more patients to answer long-term follow-up questions after surgical procedures, providing high-quality information regarding morbidity related to treatment. Although our initial results indicate that this app may become a useful tool in obtaining more frequent and realistic answers, thus helping to improve surgical techniques, other ways of reaching the patient should be tested to achieve higher response rates.
  • article 4 Citação(ões) na Scopus
    Can the learning of laparoscopic skills be quantified by the measurements of skill parameters performed in a virtual reality simulator?
    (2013) SANDY, Natascha Silva; CRUZ, Jose Arnaldo Shiomi da; PASSEROTTI, Carlo Camargo; NGUYEN, Hiep; REIS, Sabrina Thalita dos; GOUVEIA, Eder Maxwell; DUARTE, Ricardo Jordao; BRUSCHINI, Homero; SROUGI, Miguel
    Purpose: To ensure patient safety and surgical efficiency, much emphasis has been placed on the training of laparoscopic skills using virtual reality simulators. The purpose of this study was to determine whether laparoscopic skills can be objectively quantified by measuring specific skill parameters during training in a virtual reality surgical simulator (VRSS). Materials and Methods: Ten medical students (with no laparoscopic experience) and ten urology residents (PGY3-5 with limited laparoscopic experience) were recruited to participate in a ten-week training course in basic laparoscopic skills (camera, cutting, peg transfer and clipping skills) on a VRSS. Data were collected from the training sessions. The time that individuals took to complete each task and the errors that they made were analyzed independently. Results: The mean time that individuals took to complete tasks was significantly different between the groups (p < 0.05), with the residents being faster than the medical students. The residents' group also completed the tasks with fewer errors. The majority of the subjects in both groups exhibited a significant improvement in their task completion time and error rate. Conclusion: The findings in this study demonstrate that laparoscopic skills can be objectively measured in a VRSS based on quantified skill parameters, including the time spent to complete skill tasks and the associated error rate. We conclude that a VRSS is a feasible tool for training and assessing basic laparoscopic skills.
  • article 3 Citação(ões) na Scopus
    Robotic-assisted laparoscopic partial nephrectomy: initial experience in Brazil and a review of the literature
    (2012) PASSEROTTI, Carlo Camargo; PESSOA, Rodrigo; CRUZ, Jose Arnaldo Shiomi da; OKANO, Marcelo Takeo; ANTUNES, Alberto Azoubel; NESRALLAH, Adriano Joao; DALL'OGLIO, Marcos Francisco; ANDRADE, Enrico; SROUGI, Miguel
    Context and Purpose: Partial nephrectomy has become the standard of care for renal tumors less than 4 cm in diameter. Controversy still exists, however, regarding the best surgical approach, especially when minimally invasive techniques are taken into account. Robotic-assisted laparoscopic partial nephrectomy (RALPN) has emerged as a promising technique that helps surgeons achieve the standards of open partial nephrectomy care while offering a minimally invasive approach. The objective of the present study was to describe our initial experience with robotic-assisted laparoscopic partial nephrectomy and extensively review the pertinent literature. Materials and Methods: Between August 2009 and February 2010, eight consecutive selected patients with contrast enhancing renal masses observed by CT were submitted to RALPN in a private institution. In addition, we collected information on the patients' demographics, preoperative tumor characteristics and detailed operative, postoperative and pathological data. In addition, a PubMed search was performed to provide an extensive review of the robotic-assisted laparoscopic partial nephrectomy literature. Results: Seven patients had RALPN on the left or right sides with no intraoperative complications. One patient was electively converted to a robotic-assisted radical nephrectomy. The operative time ranged from 120 to 300 min, estimated blood loss (EBL) ranged from 75 to 400 mL and, in five cases, the warm ischemia time (WIT) ranged from 18 to 32 min. Two patients did not require any clamping. Overall, no transfusions were necessary, and there were no intraoperative complications or adverse postoperative clinical events. All margins were negative, and all patients were disease-free at the 6-month follow-up. Conclusions: Robotic-assisted laparoscopic partial nephrectomy is a feasible and safe approach to small renal cortical masses. Further prospective studies are needed to compare open partial nephrectomy with its minimally invasive counterparts.
  • article 0 Citação(ões) na Scopus
    Diameter of ureteral access sheath and ureteral stenosis development: a systematic review
    (2023) PISSAIA, Tamires Battistini; BELKOVSKY, Mikhael; PASSEROTTI, Carlo Camargo; ARTIFON, Everton Luiz de Almeida; OTOCH, Jose Pinhata; CRUZ, Jose Arnaldo Shiomi da
    Purpose: Ureteral access sheaths (UAS) are widely used in ureteroscopy. UAS are believed to pose a significant risk for ureteral stenosis due to ureteral mucosal compression, but little evidence supports this claim. Our systematic review aimed to investigate the relationship between different UAS diameters and stenosis risk. Methods: A systematic search was conducted in PubMed, Embase, Web of Science, Scopus, and Cochrane, from its inception to May 2023. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and Cochrane guidelines were followed. chi 2 test was performed to compare the prevalence within the groups. Results: Six nonrandomized trials and one randomized, with a total of 962 patients, were included. The overall incidence of ureteral stenosis of 0.9%. UAS sizes were: 9.5/11.5Fr, 10/12Fr, 11/13Fr, 12/14Fr, and 14/16Fr. Within each subgroup, the incidence of ureteral stenosis was: 0.4, 8, 0, 1, and 1% (p = 0.099). No trend for stenosis was observed among larger UAS. Conclusion: In this systematic review, no relationship between UAS diameter and incidence of ureteral stenosis was observed. Nonetheless, additional randomized controlled trials are required to support this finding.