MARCOS EDUARDO LERA DOS SANTOS

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina - Médico

Resultados de Busca

Agora exibindo 1 - 8 de 8
  • article 1 Citação(ões) na Scopus
    Pure Cut or Endocut for Biliary Sphincterotomy? A Multicenter Randomized Clinical Trial
    (2023) FUNARI, Mateus Pereira; BRUNALDI, Vitor Ottoboni; PROENCA, Igor Mendonca; GOMES, Pedro Victor Aniz; QUEIROZ, Lucas Tobias Almeida; VIEIRA, Yuri Zamban; MATUGUMA, Sergio Eiji; IDE, Edson; FRANZINI, Tomazo Antonio Prince; SANTOS, Marcos Eduardo Lera dos; CHENG, Spencer; MINATA, Mauricio Kazuyoshi; SANTOS, Jose Sebastio dos; MOURA, Diogo Turiani Hourneaux de; KEMP, Rafael; MOURA, Eduardo Guimares Hourneaux de
    INTRODUCTION: Adverse events (AE) after endoscopic retrograde cholangiopancreatography (ERCP) are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger PEP or bleeding. Therefore, this study evaluated the outcomes of 2 electric current modes used during biliary sphincterotomy. METHODS: From October 2019 to August 2021, consecutive patients with native papilla undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation. RESULTS: A total of 550 patients were randomized (272 pure cut and 278 endocut). The overall PEP rate was 4.0% and significantly higher in the endocut group (5.8% vs 2.2%, P = 0.034). Univariate analysis revealed >5 attempts (P = 0.004) and endocut mode (P = 0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (P = 0.005) and a trend for endocut mode as risk factors for PEP (P = 0.052). Intraprocedural bleeding occurred more often with pure cut (P = 0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with endocut (P = 0.047). There was no difference in perforation (P = 1.0) or infection (P = 0.4999) between the groups. DISCUSSION: Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCT assessing the impact of electric current on AE with overlapping preventive measures such as rectal nonsteroidal anti-inflammatory drugs and hyperhydration are needed. The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.
  • article 2 Citação(ões) na Scopus
    Homemade endoscopic vacuum therapy device for the management of transmural gastrointestinal defects
    (2023) MOURA, Diogo Turiani Hourneaux de; HIRSCH, Bruno Salomao; MCCARTY, Thomas R.; SANTOS, Marcos Eduardo dos; GUEDES, Hugo Goncalo; GOMES, Guilherme Francisco; MEDEIROS, Flaubert Sena de; MOURA, Eduardo Guimaraes Hourneaux de
    ObjectivesEndoscopic vacuum therapy (EVT) possesses a unique mechanism of action providing a less invasive alternative for the management of transmural gastrointestinal defects (TGID). This study evaluates the efficacy and safety of a novel homemade EVT (H-EVT) for the treatment of TGID. MethodsRetrospective multicenter study including patients who underwent H-EVT for TGID between January 2019 and January 2022. Main outcomes included technical and clinical success as well as safety outcomes. Subgroup analyses were included by defect location and classification. Logistic regression analyses were performed to determine predictors for successful closure. ResultsA total of 144 patients were included. Technical success was achieved in all patients, with clinical success achieved in 88.89% after a mean of 3.49 H-EVT exchanges over an average of 23.51 days. After excluding 10 cases wherein it was not possible to achieve negative pressure, successful closure occurred in 95.52% of patients. Time to clinical success was less for defects caused by endoscopic (hazard ratio [HR] 0.63; 95% confidence interval [CI] 0.33-1.20) compared to surgical procedures and for patients with simultaneous intracavitary and intraluminal H-EVT placement (HR 0.70; 95% CI 0.55-0.91). Location and classification of defect did not impact clinical success rate. Simultaneous placement of both an intraluminal and intracavitary H-EVT (odds ratio 3.08; 95% CI 1.19-7.95) was a significant predictor of clinical success. Three device-related adverse events (2.08%) occurred. ConclusionsThe use of the H-EVT is feasible, safe, and effective for the management of TGID.
  • conferenceObject
    PURE CUT OR ENDOCUT FOR BILIARY SPHINCTEROTOMY? A MULTICENTER RANDOMIZED CLINICAL TRIAL
    (2023) FUNARI, Mateus; BRUNALDI, Vitor; PROENCA, Igor; OLIVEIRA, Pedro Victor Aniz Gomes De; QUEIROZ, Lucas; VIEIRA, Yuri; MATUGUMA, Sergio; IDE, Edson; FRANZINI, Tomazo; SANTOS, Marcos Eduardo Lera Dos; CHENG, Spencer; MINATA, Mauricio; SANTOS, Jose Sebastiao Dos; MOURA, Diogo De; KEMP, Rafael; MOURA, Eduardo De
  • article
    Endoscopic Treatment of Complex Walled-Off Necrosis in Necrotizing Pancreatitis With Two Simultaneous Lumen-Apposing Metal Stents: A Case Report
    (2022) SANTOS, Marcos Eduardo Lera dos; PROENCA, Igor Mendonca; SASSO, Joao Guilherme Ribeiro Jordao; OLIVEIRA, Victor Lira de; RIBAS, Pedro Henrique Boraschi Vieira; BESTETTI, Alexandre Moraes; RIBEIRO, Igor Braga; ANNA, Raoni Salomao Sant; OLIVEIRA, Guilherme Henrique Peixoto de; MOURA, Eduardo Guimaraes Hourneaux de
    Organized pancreatic and peripancreatic collections are complications of pancreatitis and should be treated when symptomatic or complicated. When feasible, the endoscopic ultrasound approach presents high efficacy and low morbidity and mortality, making it the first likely option. Among the available accessories for endoscopic drainage, the lumen-apposing metal stent can be a better option, with a low migration rate; furthermore, it allows endoscopic necrosectomy. Here, we present the case of complex walled-off necrosis treated with two lumen-apposing metal stents in the same procedure. A 41-year-old male patient with walled-off necrosis presented with delayed gastric emptying and obstruction of the main biliary duct. Magnetic resonance imaging and endoscopic ultrasound revealed two non-communicating collections. We opted for endoscopic ultrasound-guided drainage with the deployment of two simultaneous lumen-apposing metal stents: one transduodenal and the other transgastric, with clinical improvement. After three weeks, endoscopic retrograde cholangiopancreatography showed a biliary fistula communicating with the periduodenal collection, which was treated with a biliary plastic stent. An endoscopic necrosectomy was performed, and the metal stents were removed. Control magnetic resonance imaging demonstrated improvement. The patient was asymptomatic at the six-month follow-up. The treatment of symptomatic complex walled-off necrosis remains a challenge and may require multiple endoscopic approaches; moreover, surgical treatment may be necessary in case of failure. In the present report, we demonstrate that the deployment of two lumen-apposing metal stents in the same procedure is feasible when necessary as it was associated with technical success and short-term clinical success.
  • article
    Self-Expandable Metal Stent (SEMS) Versus Lumen-Apposing Metal Stent (LAMS) for Drainage of Pancreatic Fluid Collections: A Randomized Clinical Trial
    (2023) SANTOS, Marcos Eduardo Lera dos; PROENCA, Igor Mendonca; MOURA, Diogo Turiani Hourneaux de; RIBEIRO, Igor Braga; MATUGUMA, Sergio Eiji; CHENG, Spencer; JR, Joao Remi de Freitas; LUZ, Gustavo de Oliveira; MCCARTY, Thomas R.; JUKEMURA, Jose; MOURA, Eduardo Guimaraes Hourneaux de
    Background and aim Endoscopic ultrasound (EUS)-guided drainage is the gold standard approach for the treatment of encapsulated pancreatic collections (EPCs) including pseudocyst and walled-off pancreatic necrosis (WON), and is associated with an equivalent clinical efficacy to surgical drainage with fewer complications and less morbidity. Drainage may be achieved via several types of stents including a fully covered self-expandable metallic stent (SEMS) and lumen-apposing metal stent (LAMS). However, to date there have been no randomized trials to compare these devices. This study aimed to compare the efficacy and safety of the SEMS versus LAMS for EUS-guided drainage of EPCs. Methods A phase IIB randomized trial was designed to compare the SEMS versus LAMS for the treatment of EPCs. Technical success, clinical success, adverse events (AEs), and procedure time were evaluated. A sample size of 42 patients was determined.
    Results There was no difference between the two groups in technical (LAMS 80.95% vs 100% SEMS, p=0.107), clinical (LAMS 85.71% vs 95.24% SEMS, p=0.606) or radiological success (LAMS 92.86% vs 83.33% SEMS, p=0.613). There was no difference in AEs including stent migration rate and mortality. The procedure time was longer in the LAMS group (mean time 43.81 min versus 24.43 min, p=0.001). There was also a difference in the number of intra-procedure complications (5 LAMS vs 0 SEMS, p=0.048). Conclusion SEMS and LAMS have similar technical, clinical, and radiological success as well as AEs. However, SEMS has a shorter procedure time and fewer intra-procedure complications compared to non-electrocauteryenhanced LAMS in this phase IIB randomized controlled trial (RCT). The choice of the type of stent used for EUS drainage of EPCs should consider device availability, costs, and personal and local experience.
  • article
    Complex Intrahepatic Lithiasis: A Case Report of Combined Treatment With Surgical Exploration of the Bilioenteric Anastomosis and Laser Lithotripsy by Cholangioscopy
    (2023) SANTOS, Marcos Eduardo Lera dos; SASSO, Joao Guilherme Ribeiro Jordao; FIGUEIRA, Estela R.; OLIVEIRA, Victor L. De; ARABI, Arthur Youssif Mota; MEIRA JUNIOR, Jose Donizeti; SILVA, Nathalia Camin Calixto Sarroche da; MOURA, Diogo Turiani De; JUKEMURA, Jose; MOURA, Eduardo Guimaraes De
    Intrahepatic lithiasis, or hepatolithiasis, is an endemic disease in southeast Asia, although, with immigration from Eastern countries, the incidence of this pathology is rising worldwide. The Latin American experience demonstrates morbidity and mortality compatible with other Western countries, but minimally invasive procedures are lacking. We demonstrate a case of a combined surgical and endoscopic approach for stone clearance.We present a case of a 47-year-old female patient with biliary enteric anastomosis to treat recurrent pyogenic cholangitis resulting from intrahepatic lithiasis. The patient was admitted to the emergency room, presented with a new episode of cholangitis, and submitted to transcutaneous hepatobiliary drainage. The multidisciplinary approach, including the endoscopic and surgical teams, successfully performed the stone clearance with laser lithotripsy and stone removal by open access. The postoperative period was uneventful, and the patient did not present any sign of recurrence after one year. A combined surgical and endoscopic approach achieved short-term clinical and technical success in this novel case. Moreover, individualizing cases requiring open surgical access is feasible, which allows a combined endoscopic approach with safety.
  • conferenceObject
    PURE CUT OR ENDOCUT FOR BILIARY SPHINCTEROTOMY? A MULTICENTER RANDOMIZED CLINICAL TRIAL
    (2023) FUNARI, Mateus; BRUNALDI, Vitor; PROENCA, Igor; OLIVEIRA, Pedro Victor Aniz Gomes De; QUEIROZ, Lucas; VIEIRA, Yuri; MATUGUMA, Sergio; IDE, Edson; FRANZINI, Tomazo; SANTOS, Marcos Eduardo Lera Dos; CHENG, Spencer; MINATA, Mauricio; SANTOS, Jose Sebastiao Dos; MOURA, Diogo De; KEMP, Rafael; MOURA, Eduardo De
  • article
    Intraductal radiofrequency ablation plus biliary stent versus stent alone for malignant biliary obstruction: a systematic review and meta-analysis
    (2024) VERAS, Matheus de Oliveira; MOURA, Diogo Turiani Hourneaux de; MCCARTY, Thomas R.; OLIVEIRA, Guilherme Henrique Peixoto de; GOMES, Romulo Sergio Araujo; LANDIM, Davi Lucena; NUNES, Felipe Giacobo; FRANZINI, Tomazo Antonio Prince; SANTOS, Marcos Eduardo Lera dos; BERNARDO, Wanderley Marques; MOURA, Eduardo Guimaraes Hourneaux de
    Background and study aims Recurrent biliary stent occlusion and tumor ingrowth remain a major concern among patients with malignant biliary obstruction (MBO) with significant impact on patient morbidity and survival. Intraductal radiofrequency ablation (RFA) has emerged as a promising treatment that seeks to extend stent patency. This study aimed to evaluate the impact of RFA on overall survival (OS) and stent patency among patients with unresectable MBO.Methods A comprehensive search of electronic databases was performed for randomized controlled trials (RCTs) comparing RFA plus biliary stent (RFA+S) versus biliary stent alone (S-alone). Outcomes assessed included overall survival, stent patency, and adverse events (AEs) with mean difference (MD) calculated from pooled proportions. Subgroup analyses were performed for hilar strictures and cholangiocarcinoma (CCA).Results Six RCTs (n=439 patients) were included and demonstrated improved survival among patients who received RFA+S (MD 85.80 days; 95% confidence interval [CI] 35.02-136.58; I 2 =97%; P <0.0009). The pooled MD for total stent patency was 22.25 days (95% CI 17.38-61.87; I (2) =97%; P =0.27). There was no difference in AEs between RFA+S vs S-alone ( P >0.05). On subgroup analyses, RFA+S was associated with improved stent patency (MD 76.73 days; 95% CI 50.11-103.34; I 2 =67%; P <0.01) and OS (MD 83.14 (95% CI 29.52-136.77; I- 2 =97%; P <0.01] for CCA. For hilar strictures, stent patency was improved among patients with RFA+S [MD 83.71 days (95% CI 24.85-142.56; I 2 =84%; P <0.01].Conclusions RFA+S improved OS in the treatment of MBO when compared with S-alone. Moreover, the RFA therapy prolonged stent patency in hilar strictures and CCA, with similar rates of AEs.