REJANE MATTAR

(Fonte: Lattes)
Índice h a partir de 2011
6
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina - Médico

Resultados de Busca

Agora exibindo 1 - 10 de 18
  • article 10 Citação(ões) na Scopus
    FECAL OCCULT BLOOD: A COMPARISON OF CHEMICAL AND IMMUNOCHEMICAL TESTS
    (2018) BORGES, Luana Vilarinho; MATTAR, Rejane; SILVA, Joyce Matie Kinoshita da; SILVA, Ana Luiza Werneck da; CARRILHO, Flair José; HASHIMOTO, Cláudio Lyoiti
    ABSTRACT BACKGROUND: Colorectal bleeding is a warning sign that may be identified by fecal occult blood testing. A positive fecal occult blood test result requires a subsequent colonoscopy, a costly and invasive examination. Therefore, the use of diagnostic tests with optimal sensitivity and specificity is warranted. In this study, we evaluated four different fecal occult blood tests in 176 patients undergoing colonoscopy and compared their results. OBJECTIVE: To assess the sensitivity, specificity and predictive values of chemical and immunochemical fecal occult blood tests in patients undergoing colonoscopy and to evaluate the degree of concordance between the tests and colonoscopy. METHODS: Patients with indications for colonoscopy also underwent fecal occult blood testing by chemical (toluidine test) and immunochemical methods, employing three commercially available kits. Based on the endoscopic findings, the colonoscopy was rated as positive or negative for colorectal bleeding. The degree of concordance between the fecal occult blood tests and the colonoscopy was evaluated by the kappa index. RESULTS: Forty-four (25%) colonoscopies were categorized as positive for colorectal bleeding. The toluidine test presented lower concordance than the immunochemical tests, which showed moderate concordance with the colonoscopy. The toluidine test had the least sensitivity, specificity, and positive and negative predictive values. CONCLUSION: The immunochemical fecal occult blood tests showed greater sensitivity, specificity and predictive values in detecting colorectal bleeding. The immunochemical tests had superior indexes of agreement with colonoscopy compared to the toluidine test.
  • article 5 Citação(ões) na Scopus
    DIAGNOSTIC ACCURACY OF GASTROPANEL® FOR ATROPHIC GASTRITIS IN BRAZILIAN SUBJECTS AND THE EFFECT OF PROTON PUMP INHIBITORS
    (2020) MATTAR, Rejane; MARQUES, Sergio Barbosa; RIBEIRO, Igor Braga; VISCONTI, Thiago Arantes de Carvalho; FUNARI, Mateus; DE MOURA, Eduardo Guimarães Hourneaux
    ABSTRACT BACKGROUND: It has been proposed that the combination of gastrin-17 (G-17), pepsinogens I and II (PGI and PGII), and anti-Helicobacter pylori (H. pylori) antibodies (GastroPanel®, BIOHIT HealthCare, Helsinki, Finland) could serve as biomarkers of atrophic gastritis. OBJECTIVE: This study aimed to ensure the diagnostic accuracy of GastroPanel® and evaluate the effect of proton pump inhibitors (PPIs) on these biomarkers. METHODS: Dyspeptic patients who underwent gastrointestinal endoscopy were enrolled in the present study. Histological findings, which were the gold standard to stratify groups, were as follows: no atrophy (controls); antrum atrophy; corpus atrophy; multifocal atrophy; and neoplasia. G-17, PGI, PGII, and anti-H. pylori immunoglobulin (Ig)G antibodies were assayed using commercially available kits. The ratio of PGI/PGII was calculated. RESULTS: Among 308 patients, 159 (51.6%) were PPI users. The overall prevalence of atrophy was 43.8% (n=135). Ninety-two (29.9%) patients were H. pylori positive according to anti-H. pylori IgG levels. G-17 levels were not low in those with antrum atrophy but were high in those with corpus and multifocal atrophies. PGI levels were significantly lower in those with corpus and multifocal atrophies. The sensitivity of PGI <30 µg/L to detect corpus atrophy was 50% (95% CI 27.8-72.1%), with a specificity of 93.2% (95% CI 84.3-97.5%), a positive likelihood ratio of 7.4 (95% CI 2.9-19.2), and a negative likelihood ratio of 0.5 (95% CI 0.3-0.8). A small number of subjects (n=6) exhibited moderate to intense atrophy (4%), among whom 66.7% exhibited decreased PGI levels. PPI significantly increased the levels of G-17 and PGI, except in those with corpus and multifocal atrophies, in whom PGI levels were not increased by PPIs. CONCLUSION: GastroPanel® (Gastrin-17, PGI, and PGI/PGII ratio) did not demonstrate high sensitivity for detecting gastric atrophy.
  • article 1 Citação(ões) na Scopus
    Hypolactasia is associated with insulin resistance in nonalcoholic steatohepatitis
    (2016) MAZO, Daniel Ferraz de Campos; MATTAR, Rejane; STEFANO, Jose Tadeu; SILVA-ETTO, Joyce Matie Kinoshita da; DINIZ, Marcio Augusto; DUARTE, Sebastiao Mauro Bezerra; RABELO, Fabiola; LIMA, Rodrigo Vieira Costa; CAMPOS, Priscila Brizolla de; CARRILHO, Flair Jose; OLIVEIRA, Claudia P.
    AIM To assess lactase gene (LCT)-13910C>T polymorphisms in Brazilian non-alcoholic fatty liver disease (NAFLD) and nonalcoholic steatohepatitis (NASH) patients in comparison with healthy controls. METHODS This was a transverse observational clinical study with NAFLD patients who were followed at the Hepatology Outpatient Unit of the Hospital das Clinicas, Sao Paulo, Brazil. The polymorphism of lactase non-persistence/ lactase persistence (LCT-13910C>T) was examined by PCR-restriction fragment length polymorphism technique in 102 liver biopsy-proven NAFLD patients (steatosis in 9 and NASH in 93) and compared to those of 501 unrelated healthy volunteers. Anthropometric, clinical, biochemical and liver histology data were analyzed. Continuous variables were compared using the t or Mann-Whitney tests, and categorical data were compared with the Fisher's exact test. Univariate logistic regression and multivariate logistic regression adjusted for gender and age were performed. RESULTS No differences in the LCT-13910 genotype frequencies were noted between the NAFLD patients (66.67% of the patients with steatosis were CC, 33.33% were CT, and none were TT; 55.91% of the patients with NASH were CC, 39.78% were CT, and 4.3% were TT; P = 0.941) and the healthy controls (59.12% were CC, 35.67% were CT, and 5.21% were TT) or between the steatosis and NASH patients. That is, the distribution of the lactase non-persistence/lactase persistence polymorphism (LCT-13910C>T) in the patients with NAFLD was equal to that in the general population. In the NASH patients, the univariate analysis revealed that the lactase nonpersistence (low lactase activity or hypolactasia) phenotype was associated with higher insulin levels (23.47 +/- 15.94 mu U/mL vs 15.8 +/- 8.33 mu U/mL, P = 0.027) and a higher frequency of insulin resistance (91.84% vs 72.22%, P = 0.02) compared with the lactase persistence phenotype. There were no associations between the LCT genotypes and diabetes (P = 0.651), dyslipidaemia (P = 0.328), hypertension (P = 0.507) or liver histology in these patients. Moreover, in the NASH patients, hypolactasia was an independent risk factor for insulin resistance even after adjusting for gender and age [OR = 5.0 (95%CI: 1.35-20; P = 0.017)]. CONCLUSION The LCT-13910 genotype distribution in Brazilian NAFLD patients was the same as that of the general population, but hypolactasia increased the risk of insulin resistance in the NASH patients.
  • article 1 Citação(ões) na Scopus
    Quantification of urinary 5-hydroxyindoleacetic acid by in-house nitrosonaphthol reaction compared with nitrosonaphthol micro column chromatography and enzyme-linked immunosorbent assay
    (2014) SILVA, Joyce Matie Kinoshita da; MATTAR, Rejane; COLAÚTO, Carlos; CARRILHO, Flair José
    The aim of this study was to compare the colorimetric ""kit"" and enzyme-linked immunosorbent assay (ELISA) methods to quantify urinary 5-hydroxyindoleacetic acid through the Goldenberg's technique, exploring the potential of replacing it. 24-hour urine samples were tested by Goldenberg's assay and compared with kits. The agreement was almost perfect for the comparison of Goldenberg's assay with both colorimetric kit, and with ELISA kit, considering ≤ 7.5 mg/24h normal cutoff value. Therefore, both ""kits"" would be good alternatives to Goldenberg's technique due to practicality and agreement between values.
  • article 5 Citação(ões) na Scopus
    DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION
    (2020) MATTAR, Rejane; MARQUES, Sergio Barbosa; MINATA, Maurício Kazuyoshi; SILVA-ETTO, Joyce Matie Kinoshita da; SAKAI, Paulo; DE MOURA, Eduardo Guimarães Hourneaux
    ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.
  • article 3 Citação(ões) na Scopus
    Efficacy of levofloxacin, amoxicillin and a proton pump inhibitor in the eradication of Helicobacter pylori in Brazilian patients with peptic ulcers
    (2015) SILVA, Fernando Marcuz; QUEIROZ, Elaine Cristina Silveira de; NAVARRO-RODRIGUEZ, Tomás; BARBUTI, Ricardo Correa; MATTAR, Rejane; IRIYA, Kiyoshi; LEE, Jin Hwa; EISIG, Jaime Natan
    OBJECTIVES: The eradication of Helicobacter (H.) pylori allows peptic ulcers in patients infected with the bacteria to be cured. Treatment with the classic triple regimen (proton pump inhibitor, amoxicillin and clarithromycin) has shown decreased efficacy due to increased bacterial resistance to clarithromycin. In our country, the eradication rate by intention to treat with this regimen is 83%. In Brazil, a commercially available regimen for bacterial eradication that uses levofloxacin and amoxicillin with lansoprazole is available; however, its efficacy is not known. Considering that such a treatment may be an alternative to the classic regimen, we aimed to verify its efficacy in H. pylori eradication. METHODS: Patients with peptic ulcer disease infected with H. pylori who had not received prior treatment were treated with the following regimen: 30 mg lansoprazole bid, 1,000 mg amoxicillin bid and 500 mg levofloxacin, once a day for 7 days. RESULTS: A total of 66 patients were evaluated. The patients’ mean age was 52 years, and women comprised 55% of the sample. Duodenal ulcers were present in 50% of cases, and gastric ulcers were present in 30%. The eradication rate was 74% per protocol and 73% by intention to treat. Adverse effects were reported by 49 patients (74%) and were mild to moderate, with a prevalence of diarrhea complaints. CONCLUSIONS: Triple therapy comprising lansoprazole, amoxicillin and levofloxacin for 7 days for the eradication of H. pylori in Brazilian peptic ulcer patients showed a lower efficacy than that of the classic triple regimen.
  • article 11 Citação(ões) na Scopus
    Standard Triple Therapy versus Sequential Therapy in Helicobacter pylori Eradication: A Double-Blind, Randomized, and Controlled Trial
    (2015) EISIG, Jaime Natan; NAVARRO-RODRIGUEZ, Tomas; TEIXEIRA, Ana Cristina Sa; SILVA, Fernando Marcuz; MATTAR, Rejane; CHINZON, Decio; HARO, Christiane; DINIZ, Marcio Augusto; MORAES-FILHO, Joaquim Prado; FASS, Ronnie; BARBUTI, Ricardo Correa
    Aim. To compare 10-day standard triple therapy versus sequential therapy as first-line treatment in patients infected with H. pylori. Methods. One hundred H. pylori positive patients (diagnosed by rapid urease test and histology), with average age of 47.2, M/F = 28/72, were randomized to receive either standard triple treatment (TT) as follows: lansoprazole 30 mg, clarithromycin 500 mg, and amoxicillin 1 g, b.i.d. for ten days, or sequential treatment (ST) as follows: lansoprazole 30 mg, amoxicillin and placebo 1.0 g b.i.d for the first five days, followed by lansoprazole 30 mg, clarithromycin 500 mg, and tinidazole 500 mg b.i.d, for the remaining five days. Eradication rates were determined 60 days after treatment by urease, histology, or C-13-urea breath test. Results. In intention to treat (ITT) analysis, the rate of H. pylori eradication in the TT and ST groups was the same for both regimens as follows: 86% (43/50), 95% CI 93,3 to 73.4%. In Per protocol (PP) analysis, the rate of H. pylori eradication in the TT and ST groups was 87.8% (43/49), 95% CI 94,5 to 75.3% and 89.6% (43/48), 95% CI 95,8 to 77.3%, respectively. Conclusions. In Brazil, standard triple therapy is as equally effective as sequential therapy in eradicating Helicobacter pylori patients. This study was registered under Clinical Trials with number ISRCTN62400496.
  • article 10 Citação(ões) na Scopus
    Evaluation of diagnostic accuracy of two rapid stool antigen tests using an immunochromatographic assay to detect Helicobacter pylori
    (2017) SILVA-ETTO, Joyce Matie Kinoshita da; MATTAR, Rejane; VILLARES-LOPES, Cibele Aparecida; MARQUES, Sergio Barbosa; CARRILHO, Flair Jose
    Objectives: The stool antigen assay for H. pylori infection diagnosis with monoclonal antibodies is a simple and recommended technique by the Maastricht V/Florence consensus report. Recently, Pylori K-Set K-1219 (Coris Bioconcept Sprl, Belgium) and HP-F23 (Symbiosys, Brazil) have been made commercially available in Brazil. Thus, the aim of this study was to evaluate the diagnostic accuracies of these two rapid stool antigen tests by immunochromatographic assays (index tests) for the clinical practice. Design and methods: A total of 98 patients who underwent upper gastrointestinal endoscopy and 13C-urea breath test entered the study. H. pylori infection status was defined by the combination of the rapid urease test and the C-13-urea breath test (reference standard). Two observers who were aware of H. pylori status performed the reading of index tests. Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value with 95% confidence intervals, positive likelihood ratio, negative likelihood ratio and kappa index measure of agreement) were determined. Results: The index tests where in perfect agreement with the H. pylori status with kappa values of 0.87 for Pylori K-Set K-1219 and 0.92 for HP-F23. The sensitivity of HP-F23 was 97.9% (IC95%: 87.5-100) and specificity was 93.8% (IC95%; 84-97.2). The positive likelihood ratio was 15.8, and the negative likelihood ratio was 0.02. The Pylori K-Set K-1219 had a sensitivity of 87.7% (IC95%: 74.5-94.9) and a specificity of 100% (IC95%: 91.6-100); the positive likelihood ratio was infinity, and the negative likelihood ratio was 0.1. The test line on the cassette device of HP-F23 was stronger than of the Pylori K-Set K-1219. Conclusion: The HP-F23 test performed better in clinical practice. Nonetheless, the C-13-urea breath test is more reliable technique. Moreover, caution must be paid to the trace or clear pale test line readings that were observed in false positive and false negative results, leading to incorrect management of the patient.