Assessment of the mechanics of a tissue-engineered rat trachea in an image-processing environment
dc.contributor | Sistema FMUSP-HC: Faculdade de Medicina da Universidade de São Paulo (FMUSP) e Hospital das Clínicas da FMUSP | |
dc.contributor.author | SILVA, Thiago Henrique Gomes da | |
dc.contributor.author | PAZETTI, Rogerio | |
dc.contributor.author | AOKI, Fabio Gava | |
dc.contributor.author | CARDOSO, Paulo Francisco Guerreiro | |
dc.contributor.author | VALENGA, Marcelo Henrique | |
dc.contributor.author | DEFFUNE, Elenice | |
dc.contributor.author | EVARISTO, Thaiane | |
dc.contributor.author | PEGO-FERNANDES, Paulo Manuel | |
dc.contributor.author | MORIYA, Henrique Takachi | |
dc.date.accessioned | 2015-02-06T19:10:54Z | |
dc.date.available | 2015-02-06T19:10:54Z | |
dc.date.issued | 2014 | |
dc.description.abstract | OBJECTIVES: Despite the recent success regarding the transplantation of tissue-engineered airways, the mechanical properties of these grafts are not well understood. Mechanical assessment of a tissue-engineered airway graft before implantation may be used in the future as a predictor of function. The aim of this preliminary work was to develop a noninvasive image-processing environment for the assessment of airway mechanics. METHOD: Decellularized, recellularized and normal tracheas (groups DECEL, RECEL, and CONTROL, respectively) immersed in Krebs-Henseleit solution were ventilated by a small-animal ventilator connected to a Fleisch pneumotachograph and two pressure transducers (differential and gauge). A camera connected to a stereomicroscope captured images of the pulsation of the trachea before instillation of saline solution and after instillation of Krebs-Henseleit solution, followed by instillation with Krebs-Henseleit with methacholine 0.1 M (protocols A, K and KMCh, respectively). The data were post-processed with computer software and statistical comparisons between groups and protocols were performed. RESULTS: There were statistically significant variations in the image measurements of the medial region of the trachea between the groups (two-way analysis of variance [ANOVA], p < 0.01) and of the proximal region between the groups and protocols (two-way ANOVA, p < 0.01). CONCLUSIONS: The technique developed in this study is an innovative method for performing a mechanical assessment of engineered tracheal grafts that will enable evaluation of the viscoelastic properties of neo-tracheas prior to transplantation. | |
dc.description.index | MEDLINE | |
dc.description.sponsorship | CNPq (National Counsel of Technological and Scientific Development) | |
dc.identifier.citation | CLINICS, v.69, n.7, p.500-503, 2014 | |
dc.identifier.doi | 10.6061/clinics/2014(07)11 | |
dc.identifier.eissn | 1980-5322 | |
dc.identifier.issn | 1807-5932 | |
dc.identifier.uri | https://observatorio.fm.usp.br/handle/OPI/8380 | |
dc.language.iso | eng | |
dc.publisher | HOSPITAL CLINICAS, UNIV SAO PAULO | |
dc.relation.ispartof | Clinics | |
dc.rights | openAccess | |
dc.rights.holder | Copyright HOSPITAL CLINICAS, UNIV SAO PAULO | |
dc.subject | Instrumentation | |
dc.subject | Respiratory Mechanics | |
dc.subject | Trachea | |
dc.subject.other | transplantation | |
dc.subject.wos | Medicine, General & Internal | |
dc.title | Assessment of the mechanics of a tissue-engineered rat trachea in an image-processing environment | |
dc.type | article | |
dc.type.category | original article | |
dc.type.version | publishedVersion | |
dspace.entity.type | Publication | |
hcfmusp.author.external | SILVA, Thiago Henrique Gomes da:Univ Sao Paulo, Biomed Engn Lab, Escola Politecn, Sao Paulo, Brazil | |
hcfmusp.author.external | AOKI, Fabio Gava:Univ Sao Paulo, Biomed Engn Lab, Escola Politecn, Sao Paulo, Brazil | |
hcfmusp.author.external | VALENGA, Marcelo Henrique:Univ Sao Paulo, Biomed Engn Lab, Escola Politecn, Sao Paulo, Brazil | |
hcfmusp.author.external | DEFFUNE, Elenice:Univ Estadual Paulista UNESP, Tissue Engn Lab, Botucatu, SP, Brazil | |
hcfmusp.author.external | EVARISTO, Thaiane:Univ Estadual Paulista UNESP, Tissue Engn Lab, Botucatu, SP, Brazil | |
hcfmusp.author.external | MORIYA, Henrique Takachi:Univ Sao Paulo, Biomed Engn Lab, Escola Politecn, Sao Paulo, Brazil | |
hcfmusp.citation.scopus | 5 | |
hcfmusp.contributor.author-fmusphc | ROGERIO PAZETTI | |
hcfmusp.contributor.author-fmusphc | PAULO FRANCISCO GUERREIRO CARDOSO | |
hcfmusp.contributor.author-fmusphc | PAULO MANUEL PEGO FERNANDES | |
hcfmusp.description.beginpage | 500 | |
hcfmusp.description.endpage | 503 | |
hcfmusp.description.issue | 7 | |
hcfmusp.description.volume | 69 | |
hcfmusp.origem | WOS | |
hcfmusp.origem.scopus | 2-s2.0-84904387621 | |
hcfmusp.origem.wos | WOS:000341379400011 | |
hcfmusp.publisher.city | SAO PAULO | |
hcfmusp.publisher.country | BRAZIL | |
hcfmusp.relation.reference | Delaere P, 2010, NEW ENGL J MED, V362, P138, DOI 10.1056/NEJMoa0810653 | |
hcfmusp.relation.reference | Delaere PR, 2012, CURR OPIN PULM MED, V18, P313, DOI 10.1097/MCP.0b013e3283539673 | |
hcfmusp.relation.reference | Evaristo TC, 2011, INT C TISS ENG 2 201, VII, P257 | |
hcfmusp.relation.reference | Macchiarini P, 2004, J THORAC CARDIOV SUR, V128, P638, DOI 10.1016/j.jtcvs.2004.02.042 | |
hcfmusp.relation.reference | Macchiarini P, 2008, LANCET, V372, P2023, DOI 10.1016/S0140-6736(08)61598-6 | |
hcfmusp.relation.reference | Moroz A, 2009, ACTA ORTOP BRAS, V17, P43, DOI 10.1590/S1413-78522009000200008 | |
hcfmusp.relation.reference | Nakamura T, 2009, J THORAC CARDIOV SUR, V138, P811, DOI 10.1016/j.jtcvs.2008.07.072 | |
hcfmusp.relation.reference | OTSU N, 1979, IEEE T SYST MAN CYB, V9, P62 | |
hcfmusp.relation.reference | Sato T, 2010, J THORAC CARDIOV SUR, V139, P26, DOI 10.1016/j.jtcvs.2009.04.006 | |
hcfmusp.relation.reference | Silva RAM., 2011, THESIS U ESTADUAL PA | |
hcfmusp.relation.reference | Silva THG, 2011, EUR C IFMBE 5 2011 B, V37, P137 | |
hcfmusp.scopus.lastupdate | 2024-05-10 | |
relation.isAuthorOfPublication | c0ddf4de-6951-4bd9-beb8-3ee26139c877 | |
relation.isAuthorOfPublication | 1788afc1-cb84-4497-b7e5-2d7d437fe8b1 | |
relation.isAuthorOfPublication | 0fe12aa3-3661-4e4c-91b1-d5390a484e96 | |
relation.isAuthorOfPublication.latestForDiscovery | c0ddf4de-6951-4bd9-beb8-3ee26139c877 |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- art_SILVA_Assessment_of_the_mechanics_of_a_tissueengineered_rat_2014.PDF
- Tamanho:
- 390.42 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
- publishedVersion (English)