Resumo
The aim of this meta-analysis was to verify the clinical viability of single implant-retained mandibular overdentures (SIMO). An electronic search of the PubMed and Cochrane databases was performed (end date July 2017); this was supplemented by a manual search of the literature. Only prospective clinical trials and randomized controlled trials (RCTs) that evaluated SIMO with a minimum follow-up of 12 months were included. The meta-analysis was based on the Mantel Haenszel method. Dental implant and prosthetic failure were the dichotomous outcome measures; these were evaluated through the risk ratio (RR) and odds ratio (OR), with corresponding 95% confidence intervals (CI). Of 499 articles identified, nine fulfilled the inclusion criteria. A total of 205 implants were placed in patients with a mean age of 64.1 years; the cumulative survival rate was 96.6% over a mean follow-up period of 37.3 months. The procedure used (SIMO vs. two implant-retained mandibular overdenture) did not affect dental implant failure (P = 0.45) or prosthetic failure (P = 0.65): RR 1.06 (95% CI 0.91-1.23) and RR 0.88 (95% CI 0.51-1.51), respectively; OR 2.56 (95% CI 0.27-24.39; P = 0.41) and OR 0.44 (95% CI 0.15-1.26; P = 0.13), respectively. Within the limitations of this systematic review and meta analysis, SIMO with a complete denture as the opposing arch may be considered an alternative treatment for completely edentulous patients. However, this study also confirmed the need for more RCTs on this topic.
Palavras-chave
overdenture, dental implant, single implant, meta-analysis
Referências
- Alqutaibi AY, 2017, INT J ORAL MAX SURG, V46, P789, DOI 10.1016/j.ijom.2017.02.001
- Alqutaibi AY, 2016, J EVID-BASED DENT PR, V16, P44, DOI 10.1016/j.jebdp.2016.01.009
- Alsabeeha N, 2010, INT J PROSTHODONT, V23, P160
- Alsabeeha N, 2009, CLIN ORAL IMPLAN RES, V20, P356, DOI 10.1111/j.1600-0501.2008.01666.x
- Alsabeeha NHM, 2011, INT J PROSTHODONT, V24, P247
- Alsabeeha NHM, 2011, CLIN ORAL IMPLAN RES, V22, P330, DOI 10.1111/j.1600-0501.2010.02004.x
- Alsabeeha NHM, 2010, CLIN ORAL IMPLAN RES, V21, P563, DOI 10.1111/j.1600-0501.2009.01890.x
- Bhat Srinidhi, 2016, J Indian Prosthodont Soc, V16, P182, DOI 10.4103/0972-4052.176522
- Borenstein M, 2010, RES SYNTH METHODS, V1, P97, DOI 10.1002/jrsm.12
- Bryant SR, 2015, J DENT RES, V94, P36, DOI 10.1177/0022034514554224
- Bueno-Samper A, 2010, MED ORAL PATOL ORAL, V15, pE375, DOI 10.4317/medoral.15.e375
- Chappuis V, 2013, CLIN IMPLANT DENT R, V15, P780, DOI 10.1111/cid.12056
- Cheng T, 2012, J DENT, V40, P1018, DOI 10.1016/j.jdent.2012.08.011
- Cordioli C, 1997, J PROSTHET DENT, V78, P159
- Cordioli G P, 1993, Minerva Stomatol, V42, P469
- Cvetanovich GL, 2014, ARTHROSCOPY, V30, P1616, DOI 10.1016/j.arthro.2014.05.040
- Duval S, 2000, BIOMETRICS, V56, P455, DOI 10.1111/j.0006-341X.2000.00455.x
- El-Sheikh AM, 2012, INT J DENT, DOI 10.1155/2012/236409
- Feine J S, 2002, Int J Oral Maxillofac Implants, V17, P601
- Gonda T, 2010, J PROSTHET DENT, V103, P178, DOI 10.1016/S0022-3913(10)60026-1
- Grover M, 2014, CLIN ORAL IMPLAN RES, V25, P580, DOI 10.1111/clr.12111
- Harder S, 2011, J DENT, V39, P656, DOI 10.1016/j.jdent.2011.07.007
- Harel N, 2013, INT J PROSTHODONT, V26, P244, DOI 10.11607/ijp.3044
- Ismail Hussien Abdelfattah, 2015, J Int Oral Health, V7, P4
- Jadad AR, 1996, CONTROL CLIN TRIALS, V17, P1, DOI 10.1016/0197-2456(95)00134-4
- John Jins, 2012, J Indian Prosthodont Soc, V12, P37, DOI 10.1007/s13191-012-0114-0
- Kern M, 2012, IMPLANTOLOGIE, V20, P23
- Kono K, 2014, IMPLANT DENT, V23, P456, DOI 10.1097/ID.0000000000000099
- Krennmair G, 2001, INT J ORAL MAX IMPL, V16, P98
- Kronstrom M, 2017, INT J ORAL MAX IMPL, V32, P128, DOI 10.11607/jomi.4824
- Kronstrom M, 2014, CLIN IMPLANT DENT R, V16, P323, DOI 10.1111/cid.12006
- Kronstrom M, 2010, INT J ORAL MAX IMPL, V25, P181
- Lahoti Krishnakumar, 2016, Indian J Dent Res, V27, P597, DOI 10.4103/0970-9290.199587
- LANDIS JR, 1977, BIOMETRICS, V33, P159, DOI 10.2307/2529310
- Lee DJ, 2011, INT J PROSTHODONT, V24, P71
- Liddelow G, 2010, INT J PROSTHODONT, V23, P13
- Liddelow GJ, 2007, J PROSTHET DENT, V97, pS126, DOI 10.1016/S0022-3913(07)60016-X
- Liu JY, 2013, J DENT, V41, P241, DOI 10.1016/j.jdent.2012.11.008
- Nascimento JFM, 2015, J PROSTHODONT, V24, P538, DOI 10.1111/jopr.12269
- Maeda Y, 2008, CLIN ORAL IMPLAN RES, V19, P271, DOI 10.1111/j.1600-0501.2007.01425.x
- Mahoorkar Sudhindra, 2016, J Indian Prosthodont Soc, V16, P75, DOI 10.4103/0972-4052.164881
- Moher D, 2009, ANN INTERN MED, V151, P264, DOI 10.7326/0003-4819-151-4-200908180-00135
- Muller F, 2012, CLIN ORAL IMPLAN RES, V23, P144, DOI 10.1111/j.1600-0501.2011.02213.x
- Mundt T, 2017, CLIN ORAL INVEST, V21, P635, DOI 10.1007/s00784-016-1930-0
- Nischal K, 2016, CASE REP DENT, V2016
- Nogueira TE, 2016, TRIALS, V17, DOI 10.1186/s13063-016-1646-0
- Passia N, 2017, J ORAL REHABIL, V44, P213, DOI 10.1111/joor.12473
- Passia N, 2017, INT J PROSTHODONT, V30, P43, DOI 10.11607/ijp.4975
- Passia N, 2015, CLIN ORAL IMPLAN RES, V26, P1191, DOI 10.1111/clr.12427
- Passia N, 2014, CLIN ORAL INVEST, V18, P1719, DOI 10.1007/s00784-014-1248-8
- Passia N, 2014, TRIALS, V15, DOI 10.1186/1745-6215-15-186
- Plint AC, 2006, MED J AUSTRALIA, V185, P263
- Schneider GB, 2011, SPEC CARE DENT, V31, P138, DOI 10.1111/j.1754-4505.2011.00196.x
- Srinivasan M, 2016, CLIN ORAL IMPLAN RES, V27, P63, DOI 10.1111/clr.12513
- Tavakolizadeh S, 2015, J ADV PROSTHODONT, V7, P191, DOI 10.4047/jap.2015.7.3.191
- Walton JN, 2009, INT J PROSTHODONT, V22, P331
- Wolfart S, 2008, QUINTESSENCE INT, V39, P541