An unusual presentation of low QRS voltage in a patient with aortic aneurysm

Carregando...
Imagem de Miniatura
Citações na Scopus
0
Tipo de produção
article
Data de publicação
2024
Título da Revista
ISSN da Revista
Título do Volume
Editora
CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
Citação
JOURNAL OF ELECTROCARDIOLOGY, v.82, p.86-88, 2024
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
There are many causes of low QRS voltage on the electrocardiogram (ECG). Although uncommon, there is evidence that an enlarged aorta can cause diminished QRS amplitude on ECG. In this case report, we describe an unusual presentation of low QRS voltage confined to the first three precordial leads (V1-V3) in a 77-year-old female with ascending aortic aneurysm. Analysis of the patient's medical history, echocardiogram and contrast-enhanced computed tomography indicates that the ECG pattern was caused by interposition of the aortic aneurysm between the heart and the skin electrodes (V1-V3), revealing a possible indirect sign for large aortic aneurysm on ECG.
Palavras-chave
Aortic aneurysm, Electrocardiogram
Referências
  1. Alpert MA, 2000, AM J CARDIOL, V85, P908, DOI 10.1016/S0002-9149(99)00894-2
  2. Cipriani A, 2022, JACC-CARDIOONCOL, V4, P458, DOI 10.1016/j.jaccao.2022.08.007
  3. Kim DH, 2017, J ELECTROCARDIOL, V50, P551, DOI 10.1016/j.jelectrocard.2017.04.016
  4. Kudo Y, 2003, CHEST, V124, P2064, DOI 10.1378/chest.124.6.2064
  5. Santos ECL, 2017, J ELECTROCARDIOL, V50, P960, DOI 10.1016/j.jelectrocard.2017.07.009
  6. Lee C, 2023, ANN NONINVAS ELECTRO, V28, DOI 10.1111/anec.13017
  7. Madias JE, 2008, J ELECTROCARDIOL, V41, P498, DOI 10.1016/j.jelectrocard.2008.06.021
  8. RODMAN D M, 1990, Journal of Emergency Medicine, V8, P607, DOI 10.1016/0736-4679(90)90458-8