MARIA VALERIA SCHMIDT GOFFI GOMEZ

(Fonte: Lattes)
Índice h a partir de 2011
10
Projetos de Pesquisa
Unidades Organizacionais
Instituto Central, Hospital das Clínicas, Faculdade de Medicina
LIM/32 - Laboratório de Otorrinolaringologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 10 de 26
  • article 1 Citação(ões) na Scopus
    Speech Perception Performance of Double Array Multichannel Cochlear Implant Users With Standard and Duplicated Maps in Each of the Arrays
    (2013) BENTO, Ricardo Ferreira; GOFFI-GOMEZ, Maria Valeria Schmidt; TSUJI, Robinson Koji; FONSECA, Anna Carolina de Oliveira; IKARI, Liliane Satomi; BRITO NETO, Rubens Vuono de
    Objective: The present investigation evaluated the speech perception performance of patients with ossified cochlea implanted with the 24M Double Array cochlear implant, using standard and duplicated maps in each of the arrays. Study Design: Retrospective case review. Setting: Tertiary referral center. Patients: Sixteen subjects received a Double Array cochlear implant. Among these, 9 fulfilled the following inclusion criteria: bilateral severe-to- profound postlingual deafness; bilateral obliterated cochlea, as shown by a computed tomographic scan; and a minimum age of 14 years to ensure reliable responses in the behavioral tests with the 3 tested maps. Intervention: Rehabilitative. Main Outcome Measures: The speech perception performance with the 2 arrays was compared with that with a basal array duplicated map and an apical array duplicated map. Three maps were fitted: the default map with both arrays activated, a double channel map using only the electrodes of the basal array, and a double channel map programmed only with the electrodes of the apical array. The test battery was composed of a vowel test, a 4-choice word test, and sentence recognition in quiet. Results: Statistical significance was reached in comparison the all tests in all programming conditions. Speech recognition in the standard map with both electrode arrays activated showed the highest scores. Conclusion: Performance with the 2 split electrode arrays was superior to those with the single arrays, regardless of the duplication of channels.
  • article 5 Citação(ões) na Scopus
    Microangiopathy of the inner ear, deafness, and cochlear implantation in a patient with Susac syndrome
    (2011) BITTENCOURT, Aline Gomes; SANTOS, Andrea Felice Dos; GOFFI-GOMEZ, Maria Valeria Schmidt; KUTSCHER, Kellen; TSUJI, Robinson Koji; BRITO, Rubens De; BENTO, Ricardo Ferreira
    Conclusion: The cochlear implant was beneficial as an attempt to restore hearing and improve communication abilities in this patient with profound sensorineural hearing loss secondary to Susac syndrome. Objective: To report the audiological outcomes of cochlear implantation (CI) in a young woman with Susac syndrome after a 6-month follow-up period. Susac syndrome is a rare disorder. It is clinically characterized by a typical triad of sensorineural deafness, encephalopathy, and visual defect, due to microangiopathy involving the brain, inner ear, and retina. Methods: This was a retrospective review of a case at a tertiary referral center. After diagnosis, the patient was evaluated by a multidisciplinary team and received a cochlear implant in her right ear. Results: The patient achieved 100% open-set sentence recognition in noise conditions and 92% monosyllable and 68% medial consonant recognition in quiet conditions after 6 months of implant use. She reported the use of the telephone 3 months after activation.
  • article 15 Citação(ões) na Scopus
    Hearing preservation using topical dexamethasone alone and associated with hyaluronic acid in cochlear implantation
    (2015) RAMOS, Bernardo Faria; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira; GOFFI-GOMEZ, Maria Valeria Schmidt; RAMOS, Henrique Faria; SAMUEL, Paola Angelica; BRITO, Rubens
    Conclusion: Topical dexamethasone associated with hyaluronic acid in cochlear implant surgery demonstrated a statistically significant difference in the preservation of low-frequency thresholds when compared with topical dexamethasone alone and a control group. Topical dexamethasone alone was not superior in hearing preservation when compared to the control group. Objective: To compare the effects of topical dexamethasone alone and associated with hyaluronic acid intraoperatively in hearing preservation in cochlear implantation. Methods: Eighteen severely to profoundly hearing-impaired adult patients with measurable hearing were divided into three groups preoperatively: cochlear implantation as a control group (group 1), cochlear implantation using topical dexamethasone intraoperatively (group 2), and cochlear implantation using topical dexamethasone associated with hyaluronic acid intraoperatively (group 3). Preimplant and postimplant low-frequency pure-tone averages (PTAs) were calculated from unaided audiograms at 125, 250, and 500 Hz. Results: The mean changes in the low-frequency PTA comparing postoperative against preoperative thresholds were 28.03 +/- 6.77 dB in group 1, 30 +/- 14.53 dB in group 2, and 7.23 +/- 6.12 dB in group 3. There was statistical difference when comparing group 3 with groups 1 and 2 using one-way ANOVA (p = 0.002) followed by Scheffe post hoc test.
  • article 0 Citação(ões) na Scopus
    Is There Any Correlation between Spread of Excitation Width and the Refractory Properties of the Auditory Nerve in Cochlear Implant Users?
    (2021) SILVA, Juliana Coutinho da; GOFFI-GOMEZ, Maria Valeria Schmidt; TSUJI, Robinson Koji; BENTO, Ricardo; BRITO NETO, Rubens
    Background: The spread of excitation (SOE) and auditory nerve recovery function (REC) are objective measures recorded by neural response telemetry and may interfere in cochlear implant (CI) stimulation. Objective: To analyze and correlate SOE with the refractory periods in subjects with pre- and postlingual deafness implanted with different electrode arrays. Methods: This was a retrospective study of 323 ears separated by perimodiolar or straight arrays and by pre- or postlingually deaf recipients. Measures were collected intraoperatively on electrode 11. The SOE width was measured in millimeters at the 0.75 point of the curve, and the relative (tau) and absolute (t0) refractory periods were measured in microseconds. Results: There was a statistical correlation between the SOE and the t0 in the patients with postlingual deafness implanted with the perimodiolar array. The SOE width was statistically different between the straight and perimodiolar arrays and between the pre- and postlingual groups in the perimodiolar array. Tau was statistically different between the pre- and postlingual groups with the straight array and the t0, between the pre- and postlingual groups with the perimodiolar array. Neural response threshold and amplitude of the neural response were not statistically different among groups. Conclusion: There was a correlation between SOE width and t0 only in patients with acquired deafness. The findings suggest that different factors influence SOE and REC, considering SOE is different according to the electrode array and REC being different according the onset of deafness.
  • article 10 Citação(ões) na Scopus
    Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation
    (2013) BENTO, Ricardo Ferreira; MONTEIRO, Tatiana Alves; BITTENCOURT, Aline Gomes; GOFFI-GOMEZ, Maria Valeria Schmidt; BRITO, Rubens de
    INTRODUCTION: Few cases of cochlear implantation (CI) in neurofibromatosis type 2 (NF2) patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. OBJECTIVES: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. RESUMED REPORT: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. CONCLUSION: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.
  • article 9 Citação(ões) na Scopus
    Are Auditory Steady-State Responses Useful to Evaluate Severe-to-Profound Hearing Loss in Children?
    (2015) GRASEL, Signe Schuster; ALMEIDA, Edigar Rezende de; BECK, Roberto Miquelino de Oliveira; GOFFI-GOMEZ, Maria Valeria Schmidt; RAMOS, Henrique Faria; ROSSI, Amanda Costa; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira; BRITO, Rubens de
    Objective. To evaluate Auditory Steady-State Responses (ASSR) at high intensities in pediatric cochlear implant candidates and to compare the results to behavioral tests responses. Methods. This prospective study evaluated 42 children with suspected severe-to-profound hearing loss, aged from 3 to 72 months. All had absent ABR and OAE responses. ASSR were evoked using binaural single frequency stimuli at 110 dB HL with a 10 dB down-seeking procedure. ASSR and behavioral test results were compared. Results. Forty-two subjects completed both ASSR and behavioral evaluation. Eleven children (26.2%) had bilateral responses. Four (9.5%) showed unilateral responses in at least two frequencies, all confirmed by behavioral results. Overall 61 ASSR responses were obtained, most (37.7%) in 500 Hz. Mean thresholds were between 101.3 and 104.2 dB HL. Among 27 subjects with absent ASSR, fifteen had no behavioral responses. Seven subjects showed behavioral responses with absent ASSR responses. No spurious ASSR responses were observed at 100 or 110 dB HL. Conclusion. ASSR is a valuable tool to detect residual hearing. No false-positive ASSR results were observed among 42 children, but in seven cases with absent ASSR, the test underestimated residual hearing as compared to the behavioral responses.
  • article 0 Citação(ões) na Scopus
    Can the use of the CROS system provide head shadow effect contribution to unilateral Cochlear Implant Users?
    (2022) HOSHINO, Ana Cristina Hiromi; GOFFI-GOMEZ, Maria Valeria Schmidt; SIERRA, Paola Angelica Samuel; AGRAWAL, Smita; RODRIGUEZ, Carina; CARVALHO, Ana Claudia Martinho de; TSUJI, Robinson Koji
    Purpose: The aim of this study was to evaluate the contribution of the CROS system on the head shadow effect in unilateral implant users. Methods: Prospective cross-sectional study, approved by the ethics committee under protocol 2.128.869. Eleven adults with post-lingual deafness users of unilateral Advanced Bionics CI were selected. Speech recognition was evaluated with recorded words presented at 65dBA at 0o azimuth and at 90o on the side contralateral to the CI, with noise at 55dBA, using CI alone and CI + CROS system. The results were analyzed using paired t-test with a 0.05 alpha. Results: The mean speech recognition scores were significantly better with CI + CROS in relation to the condition of CI alone (p <0.05, p <0.005 and p <0.005 respectively). In the presentation at 0o azimuth, no significant differences were found. Conclusion: Users of unilateral CI without useful residual hearing for the use of hearing aids or unable to undergo bilateral surgery can benefit from the CROS device for speech recognition, especially when the speech is presented on the side contralateral to the CI.
  • article 6 Citação(ões) na Scopus
    Is the spread of excitation width correlated to the speech recognition in cochlear implant users?
    (2021) SILVA, Juliana Coutinho da; GOFFI-GOMEZ, Maria Valeria Schmidt; MAGALHAES, Ana Tereza; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira
    Purpose To assess whether there is an interference of the spread of excitation (SOE) on speech recognition. Methods Retrospective cross-sectional study, approved by the institution's ethics committee (CAAE03409212.8.0000.0068). Adult patients with intraoperative neural response telemetry (NRT) performed on electrodes 6, 11 and 16 implanted with Cochlear Ltd (Sydney, Australia) devices were selected. Patients with partial array insertion, pre-lingual hearing loss, deafness etiology due to and CI experience less than 12 months were excluded. SOE was recorded at 10 current units above the NRT threshold (tNRT) and its width in millimeters was collected at point 0.75 of the function. Speech recognition test was 25-recorded monosyllables list, presented at 65 dBHL at 0 degrees azimuth in a sound treated booth. The analysis was divided into groups by electrode array type, regarding the tNRT, SOE width, SOE's peak amplitude and electrode peak. Results A 126 SOE measurements of the 3 tested electrodes were obtained from 43 patients. Patients with straight array had significantly wider SOE, greater peak amplitude at electrode 6 and higher tNRTs. In the perimodiolar array, there was a negative correlation between SOE and monosyllables recognition at electrodes 6 and 11, and in the combined average of the three electrodes, with a significant difference in electrode 11. Sixty-six percent of the SOE measurements had their peak shifted to adjacent electrodes. Conclusion It was observed, in perimodiolar array, the greater the dispersion of electrical current, the worse the speech recognition, especially in the medial electrode.
  • article 3 Citação(ões) na Scopus
    Do the minimum and maximum comfortable stimulation levels influence the cortical potential latencies or the speech recognition in adult cochlear implant users?
    (2021) MARTINS, Kelly Vasconcelos Chaves; GOFFI-GOMEZ, Maria Valeria Schmidt; TSUJI, Robinson Koji; BENTO, Ricardo Ferreira
    Introduction: Cochlear implants (CI) programming is based on both the measurement of the minimum levels required to stimulate the auditory nerve and the maximum levels to generate loud, yet comfortable loudness. Seeking for guidance in the adequacy of this programming, the cortical auditory evoked potentials (CAEP) have been gaining space as an important tool in the evaluation of CI users, providing information on the central auditory system. Objective: To evaluate the influence of mishandling of electrical stimulation levels on speech processor programming on hearing thresholds, speech recognition and cortical auditory evoked potential in adult CI users. Material and methods: This is a prospective cross-sectional study, with a sample of adult unilateral CI users of both sexes, aged at least 18 years, post-lingual deafness, with minimum experience of 12 months of device use. Selected subjects should have average free field hearing thresholds with cochlear implant equal to or better than 34 dBHL and monosyllable recognition different from 0%. Individuals who could not collaborate with the procedures or who had no CAEP recordings were excluded. Participants were routinely programmed, and the map was named MO (optimized original map). Then three experimentally wrong maps were made: optimized original map with 10 current units below the maximum comfort level (C), named MC-(map minus C); optimized original map with minus 10 current units at minimum threshold level (T), named MT-(map minus T) and optimized original map with 10 current units above minimum level (T), named MT + (map plus T). In all programs, participants underwent free-field auditory thresholds from 250Hz to 60 0 0Hz, recorded sentences and monosyllabic recognition tests presented at 65dB SPL in quiet and in noise, and free field CAEP evaluation. All tests were performed in an acoustically treated booth, in a randomized order of map presentation. Data were compared by Wilcoxon test. Results: Thirty individuals were selected and signed an informed consent form. The MC-map provided worsening of all free field thresholds, quiet and noise speech recognition, and P1 wave latency delay with significant difference from the results with the MO map. The MT-map worsened the hearing thresholds and statistically significantly reduced the P2 wave latency; MT + map improved free field thresholds except 60 0 0Hz, worsening speech recognition, without statistical significance. Conclusions: The results suggest that maximum levels below the optimal thresholds lead to worse cochlear implant performance in both hearing thresholds and speech recognition tests in quiet and noise, increasing CAEP component P1 latency. On the other hand, the manipulation of minimum threshold levels showed alteration in audibility without significant impact on speech recognition.
  • article 3 Citação(ões) na Scopus
    Are There Cochlear Dead Regions Involved in Hearing Loss after Cisplatin Ototoxicity?
    (2019) SCHULTZ, Christiane; LIBERMAN, Patricia Helena Pecora; GOFFI-GOMEZ, Maria Valeria Schmidt
    Background: The most common complaint of patients affected by chemotherapy-induced hearing loss is difficulty understanding speech in noisy environments despite the use of hearing aids. Cochlear dead regions, those areas with damaged or absent inner hair cells and dendrites, may account for this type of hearing loss. However, it is unknown whether this condition is associated with cisplatin agents. Objective: The aim of this study was to determine whether cisplatin is associated with hearing loss and cochlear dead regions. Methods: This prospective cross-sectional study was conducted in patients participating in routine audiological monitoring during and after chemotherapy treatment. Adults undergoing audiological evaluation who had completed chemotherapy treatment were invited to participate. Patients were divided into 3 groups according to pure tone thresholds. Group 1 patients had thresholds over 70 dB (HL) at 2,000 Hz and higher frequencies. Group 2 patients had thresholds below 70 dB (HL) up to 2,000 Hz. Patients in the control group had normal thresholds at all frequencies. The threshold equalizing noise test (TEN[HL]) was used to identify cochlear dead regions by repeating thresholds in the presence of TEN noise played from a compact disc. The presence of cochlear dead regions was established when the masked threshold was 10 dB or greater above the TEN level and 10 dB or greater above the absolute threshold at any frequency. Results: Twelve patients were included in study group 1, 10 patients in study group 2, and 7 patients in the control group. Cochlear dead regions were present in all patients with hearing loss and in none of the control group. For groups 1 and 2, mean differences between absolute and masked thresholds were 21 and 16 dB at 500 Hz; 22 and 15 dB at 1,000 Hz; 31 and 17 dB at 2,000 Hz; 32 and 20 dB at 3,000 Hz; and 31 and 21 dB at 4,000 Hz, respectively. Nevertheless, analysis of variance testing with Bonferroni analysis showed a difference between groups 1 and 2 only at 2,000, 3,000, and 4,000 Hz. Conclusion: We found unresponsive or dead cochlear regions in patients who had undergone cisplatin chemotherapy even among patients with mild to moderate hearing loss.