ELIZABETH SARTORI CREVELARI

(Fonte: Lattes)
Índice h a partir de 2011
6
Projetos de Pesquisa
Unidades Organizacionais
Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina - Médico
LIM/11 - Laboratório de Cirurgia Cardiovascular e Fisiopatologia da Circulação, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 10 de 16
  • article 3 Citação(ões) na Scopus
    Effectiveness and Safety of Transvenous Removal of Cardiac Pacing and Implantable Cardioverter-defibrillator Leads in the Real Clinical Scenario
    (2020) COSTA, Roberto; SILVA, Katia Regina da; CREVELARI, Elizabeth Sartori; NASCIMENTO, Wagner Tadeu Jurevicius; NAGUMO, Marcia Mitie; MARTINELLI FILHO, Martino; JATENE, Fabio Biscegli
    Background: Transvenous lead extraction (TLE) of cardiac implantable electronic devices (CIED) is an uncommon procedure and requires specialized personnel and adequate facilities. Objectives: To evaluate the effectiveness and safety of the removal of CIED leads and to determine risk factors for surgical complications and mortality in 30 days. Methods: Prospective study with data derived from clinical practice. From January 2014 to April 2020, we included 365 consecutive patients who underwent TLE, regardless of the indication and surgical technique used. The primary outcomes were: success rate of the procedure, combined rate of major complications and intraoperative death. Secondary outcomes were: risk factors for major intraoperative complications and death within 30 days. Univariate and multivariate analysis were used, with a significance level of 5%. Results: Procedure success rate was 96.7%, with 90.1% of complete success and 6.6% of clinical success. Major intraoperative complications occurred in 15 (4.1%) patients. Predictors of major complications were: lead dwelling time >= 7 years (OR = 3.78, p = 0.046) and change in surgical strategy (OR = 5.30, p = 0.023). Functional class III-IV (OR = 6.98, p <0.001), renal failure (OR = 5.75, p = 0.001), CIED infection (OR = 13.30, p <0.001), number of procedures performed (OR = 77.32, p <0.001) and major intraoperative complications (OR = 38.84, p <0.001) were predictors of 30-day mortality. Conclusions: The results of this study, which is the largest prospective registry of consecutive TLE procedures in Latin America, confirm the safety and effectiveness of this procedure in the context of real clinical practice.
  • bookPart
    Infecçoes de dispositivos cardiacos eletrónicos implantáveis
    (2018) COSTA, Roberto; ALBERTINI, Caio Marcos de Moraes; NASSIF JR., Miguel; CREVELARI, Elizabeth Sartori; SILVA, Kátia Regina da
  • article 22 Citação(ões) na Scopus
    Glocal Clinical Registries: Pacemaker Registry Design and Implementation for Global and Local Integration - Methodology and Case Study
    (2013) SILVA, Katia Regina da; COSTA, Roberto; CREVELARI, Elizabeth Sartori; LACERDA, Marianna Sobral; ALBERTINI, Caio Marcos de Moraes; MARTINELLI FILHO, Martino; SANTANA, Jose Eduardo; VISSOCI, Joao Ricardo Nickenig; PIETROBON, Ricardo; BARROS, Jacson V.
    Background: The ability to apply standard and interoperable solutions for implementing and managing medical registries as well as aggregate, reproduce, and access data sets from legacy formats and platforms to advanced standard formats and operating systems are crucial for both clinical healthcare and biomedical research settings. Purpose: Our study describes a reproducible, highly scalable, standard framework for a device registry implementation addressing both local data quality components and global linking problems. Methods and Results: We developed a device registry framework involving the following steps: (1) Data standards definition and representation of the research workflow, (2) Development of electronic case report forms using REDCap (Research Electronic Data Capture), (3) Data collection according to the clinical research workflow and, (4) Data augmentation by enriching the registry database with local electronic health records, governmental database and linked open data collections, (5) Data quality control and (6) Data dissemination through the registry Web site. Our registry adopted all applicable standardized data elements proposed by American College Cardiology/American Heart Association Clinical Data Standards, as well as variables derived from cardiac devices randomized trials and Clinical Data Interchange Standards Consortium. Local interoperability was performed between REDCap and data derived from Electronic Health Record system. The original data set was also augmented by incorporating the reimbursed values paid by the Brazilian government during a hospitalization for pacemaker implantation. By linking our registry to the open data collection repository Linked Clinical Trials (LinkedCT) we found 130 clinical trials which are potentially correlated with our pacemaker registry. Conclusion: This study demonstrates how standard and reproducible solutions can be applied in the implementation of medical registries to constitute a re-usable framework. Such approach has the potential to facilitate data integration between healthcare and research settings, also being a useful framework to be used in other biomedical registries.
  • article 16 Citação(ões) na Scopus
    Effects of Cardiac Resynchronization Therapy on Muscle Sympathetic Nerve Activity
    (2014) KUNIYOSHI, Ricardo R.; MARTINELLI, Martino; NEGRAO, Carlos E.; SIQUEIRA, Sergio F.; RONDON, Maria U. P. B.; TROMBETTA, Ivani C.; KUNIYOSHI, Fatima H. S.; LATERZA, Mateus C.; NISHIOKA, Silvana A. D'Orio; COSTA, Roberto; TAMAKI, Wagner T.; CREVELARI, Elizabeth S.; PEIXOTO, Giselle De Lima; RAMIRES, Jose A. F.; KALIL, Roberto
    IntroductionMuscle sympathetic nerve activity (MSNA) is an independent prognostic marker in patients with heart failure (HF). Therefore, its relevance to the treatment of HF patients is unquestionable. ObjectivesIn this study, we investigated the effects of cardiac resynchronization therapy (CRT) on MSNA response at rest and during exercise in patients with advanced HF. MethodsWe assessed 11 HF patients (51 3.4 years; New York Heart Association class III-IV; left ventricular ejection fraction 27.8 2.2%; optimal medical therapy) submitted to CRT. Evaluations were made prior to and 3 months after CRT. MSNA was performed at rest and during moderate static exercise (handgrip). Peak oxygen consumption (VO2) was evaluated by means of cardiopulmonary exercise test. HF patients with advanced NYHA class without CRT and healthy individuals were also studied. ResultsCRT reduced MSNA at rest (48.9 +/- 11.1 bursts/min vs 33.7 +/- 15.3 bursts/min, P < 0.05) and during handgrip exercise (MSNA 62.3 +/- 13.1 bursts/min vs 46.9 +/- 14.3 bursts/min, P < 0.05). Among HF patients submitted to CRT, the peak VO2 increased (12.9 +/- 2.8 mL/kg/min vs 16.5 +/- 3.9 mL/kg/min, P < 0.05) and an inverse correlation between peak VO2 and resting MSNA (r = -0.74, P = 0.01) was observed. ConclusionsIn patients with advanced HF and severe systolic dysfunction: (1) a significant reduction of MSNA (at rest and during handgrip) occurred after CRT, and this behavior was significantly superior to HF patients receiving only medical therapy; (2) MSNA reduction after CRT had an inverse correlation with O-2 consumption outcomes.
  • article 11 Citação(ões) na Scopus
    Complications after Surgical Procedures in Patients with Cardiac Implantable Electronic Devices: Results of a Prospective Registry
    (2016) SILVA, Katia Regina da; ALBERTINI, Caio Marcos de Moraes; CREVELARI, Elizabeth Sartori; CARVALHO, Eduardo Infante Januzzi de; FIORELLI, Alfredo Inacio; MARTINELLI FILHO, Martino; COSTA, Roberto
    Background: Complications after surgical procedures in patients with cardiac implantable electronic devices (CIED) are an emerging problem due to an increasing number of such procedures and aging of the population, which consequently increases the frequency of comorbidities. Objective: To identify the rates of postoperative complications, mortality, and hospital readmissions, and evaluate the risk factors for the occurrence of these events. Methods: Prospective and unicentric study that included all individuals undergoing CIED surgical procedures from February to August 2011. The patients were distributed by type of procedure into the following groups: initial implantations (cohort 1), generator exchange (cohort 2), and lead-related procedures (cohort 3). The outcomes were evaluated by an independent committee. Univariate and multivariate analyses assessed the risk factors, and the Kaplan-Meier method was used for survival analysis. Results: A total of 713 patients were included in the study and distributed as follows: 333 in cohort 1, 304 in cohort 2, and 76 in cohort 3. Postoperative complications were detected in 7.5%, 1.6%, and 11.8% of the patients in cohorts 1, 2, and 3, respectively (p = 0.014). During a 6-month follow-up, there were 58 (8.1%) deaths and 75 (10.5%) hospital readmissions. Predictors of hospital readmission included the use of implantable cardioverter-defibrillators (odds ratio [OR] = 4.2), functional class III--IV (OR = 1.8), and warfarin administration (OR = 1.9). Predictors of mortality included age over 80 years (OR = 2.4), ventricular dysfunction (OR = 2.2), functional class III-IV (OR = 3.3), and warfarin administration (OR = 2.3). Conclusions: Postoperative complications, hospital readmissions, and deaths occurred frequently and were strongly related to the type of procedure performed, type of CIED, and severity of the patient's underlying heart disease.
  • article 6 Citação(ões) na Scopus
    Functional Capacity of Patients with Pacemaker Due to Isolated Congenital Atrioventricular Block
    (2015) OLIVEIRA JUNIOR, Roberto Marcio de; SILVA, Katia Regina da; KAWAUCHI, Tatiana Satie; ALVES, Lucas Bassolli de Oliveira; CREVELARI, Elizabeth Sartori; MARTINELLI FILHO, Martino; COSTA, Roberto
    Background: Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation. Objectives: To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling. Methods: This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%. Results: A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 +/- 6.3 years. The percentage of ventricular pacing was 97.9 +/- 4.1%, and the duration of the paced QRS complex was 153.7 +/- 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 +/- 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. Conclusions: The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling.
  • bookPart
    Infecções de dispositivos cardíacos eletrônicos implantáveis
    (2015) COSTA, Roberto; ALBERTINI, Caio Marcos de Moraes; NASSIF JR., Miguel; CREVELARI, Elizabeth Sartori; SILVA, Kátia Regina da
  • bookPart
    Desfibriladores cardíacos
    (2016) COSTA, Roberto; CREVELARI, Elizabeth Sartori; SILVA, Kátia Regina da
  • article 2 Citação(ões) na Scopus
    Impact of the COVID-19 Pandemic on Cardiac Implantable Electronic Devices Procedures in a Tertiary Referral Center
    (2021) COSTA, Roberto; SILVA, Katia Regina da; SAUCEDO, Sarah Caroline Martins; SILVA, Laisa Arruda; CREVELARI, Elizabeth Sartori; NASCIMENTO, Wagner Tadeu Jurevicius; SILVEIRA, Thiago Goncalves; FIORELLI, Alfredo; MARTINELLI FILHO, Martino; JATENE, Fabio Biscegli
  • article 0 Citação(ões) na Scopus
    Prognosis Determinants after Cardioverter-Defibrillators Implantation in Brazil Reply
    (2017) SILVA, Katia Regina da; ALBERTINI, Caio Marcos de Moraes; CREVELARI, Elizabeth Sartori; CARVALHO, Eduardo Infante Januzzi de; FIORELLI, Alfredo Inacio; MARTINELLI FILHO, Martino; COSTA, Roberto