CLAYTON HENRIQUE ROCHA

(Fonte: Lattes)
Índice h a partir de 2011
4
Projetos de Pesquisa
Unidades Organizacionais
LIM/34 - Laboratório de Ciências da Reabilitação, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 6 de 6
  • article 0 Citação(ões) na Scopus
    Evaluation of Subtle Auditory Impairments with Multiple Audiological Assessments in Normal Hearing Workers Exposed to Occupational Noise
    (2023) SAMELLI, Alessandra Giannella; ROCHA, Clayton Henrique; KAMITA, Mariana Keiko; LOPES, Maria Elisa Pereira; ANDRADE, Camila Quintiliano; MATAS, Carla Gentile
    Recent studies involving guinea pigs have shown that noise can damage the synapses between the inner hair cells and spiral ganglion neurons, even with normal hearing thresholds-which makes it important to investigate this kind of impairment in humans. The aim was to investigate, with multiple audiological assessments, the auditory function of normal hearing workers exposed to occupational noise. Altogether, 60 workers were assessed (30 in the noise-exposure group [NEG], who were exposed to occupational noise, and 30 in the control group [CG], who were not exposed to occupational noise); the workers were matched according to age. The following procedures were used: complete audiological assessment; speech recognition threshold in noise (SRTN); speech in noise (SN) in an acoustic field; gaps-in-noise (GIN); transient evoked otoacoustic emissions (TEOAE) and inhibitory effect of the efferent auditory pathway; auditory brainstem response (ABR); and long-latency auditory evoked potentials (LLAEP). No significant difference was found between the groups in SRTN. In SN, the NEG performed worse than the CG in signal-to-noise ratio (SNR) 0 (p-value 0.023). In GIN, the NEG had a significantly lower percentage of correct answers (p-value 0.042). In TEOAE, the NEG had smaller amplitude values bilaterally (RE p-value 0.048; LE p-value 0.045) and a smaller inhibitory effect of the efferent pathway (p-value 0.009). In ABR, the NEG had greater latencies of wave V (p-value 0.017) and interpeak intervals III-V and I-V in the LE (respective p-values: 0.005 and 0.04). In LLAEP, the NEG had a smaller P3 amplitude bilaterally (RE p-value 0.001; LE p-value 0.002). The NEG performed worse than the CG in most of the assessments, suggesting that the auditory function in individuals exposed to occupational noise is impaired, even with normal audiometric thresholds.
  • article 0 Citação(ões) na Scopus
    Effects of Conventional and Musician-Specific Hearing Protection Devices on Speech Intelligibility
    (2023) PINTO, Giovanna Cardoso; ROCHA, Clayton Henrique; MATAS, Carla Gentile; SAMELLI, Alessandra Giannella
    (1) Background: To assess and compare speech intelligibility with conventional and universal musician-specific hearing protection devices (HPD); (2) Methods: The sample comprised 15 normal-hearing musicians of both sexes who had been professionals for more than 5 years. They underwent thorough audiological assessment and free-field audiometry to measure the attenuation levels of three HPD models (musician-specific, silicone, and foam devices). The sentence recognition thresholds in quiet (SRTQ) and noise (SRTN) were assessed with the Lists of Sentences in Portuguese. User satisfaction with musician HPD was assessed after 2 months; (3) Results: Conventional HPD had higher pure-tone mean attenuation levels than musician HPD. No statistically significant differences were found in SRTQ and SRTN between the three HPD types. However, the musician HPD had higher mean signal-to-noise ratios and percentages of correct words from sentences presented in noise than the other HPD. The answers also indicated a positive trend toward satisfaction with the musician-specific HPD; (4) Conclusions: Despite the lack of significant differences in speech intelligibility while wearing the three HPD models in either quiet or noise, the musician-specific HPD provided greater musical sound quality. This reinforces the possibility of an effective and adequate use of protection to preserve musicians' hearing.
  • article
    Translation and cross-cultural adaptation of the Noise Exposure Questionnaire (NEQ) to Brazilian Portuguese
    (2023) OLIVEIRA, Leticia Campos de; ROCHA, Clayton Henrique; MATAS, Carla Gentile; PAIVA, Karina Mary de; MOREIRA, Renata Rodrigues; SAMELLI, Alessandra Giannella
    Objective: To translate and cross-culturally adapt the Noise Exposure Questionnaire (NEQ) and 1-Minute Noise Screen (NEQ-S) instruments to Brazilian Portuguese. Methods: Procedures widely known in health research were used in the translation and cross-cultural adaptation process, comprising the following steps: initial translation, synthesis of translations, back-translation, expert committee, pretest, and content and layout validation. Altogether, 60 workers participated in the pretest by answering the questionnaires and then evaluating them in terms of understandability, layout, clarity, and writing. Reliability was verified with Cohen's kappa test, and the internal consistency was analyzed with Cronbach's alpha coefficient. Results: The translated and adapted versions of NEQ and NEQ-S were similar in terms of general and referential meanings. However, some modifications and adaptations were made to adapt them to the Brazilian reality. The kappa test indicated moderate agreement and Cronbach's alpha coefficient, substantial internal consistency. Conclusion: The translation and cross-cultural adaptation were carried out according to the methodology recommended in the national and international literature, performing the necessary equivalences to maintain the face and content validity with the original instrument. The availability of NEQ and NEQ-S in Brazilian Portuguese opens new fields of research to quantify yearly noise exposure more in-depth.
  • article 10 Citação(ões) na Scopus
    Training on hearing protector insertion improves noise attenuation
    (2015) SAMELLI, Alessandra Giannella; ROCHA, Clayton Henrique; THEODÓSIO, Patrícia; MOREIRA, Renata Rodrigues; NEVES-LOBO, Ivone Ferreira
    ABSTRACT Purpose: To determine the efficacy of hearing protector insertion by comparing attenuation values measured by objective (MIRE) and subjective (REAT) methods in groups with and without training. Methods: The study included 80 male subjects assigned to experimental (with training) and control (without training) groups. The following procedures were performed: occupational history, objective and subjective assessment of hearing protectors. Only subjects in the experimental group received training and guidance on proper hearing protector insertion. Results: Attenuation values were significantly higher in the experimental group than in the control group at all frequencies (500, 1000, 2000, and 4000 Hz) investigated through the objective (MIRE) and subjective (REAT) methods. In addition, attenuation values in the control group were lower than those provided by the hearing protector manufacturer. Conclusion: Both objective and subjective attenuation tests demonstrated the efficacy of training on insertion of hearing protectors because the group that received training on proper hearing protection insertion exhibited higher attenuation values than the untrained group.
  • article
    Effects of a vestibular rehabilitation program on workers in the working environment: a pilot study
    (2018) LONGO, Isadora Altero; NUNES, Ariane Diane Morais; ROCHA, Clayton Henrique; BRANCO, Fabiana Mara; MOREIRA, Renata Rodrigues; NEVES-LOBO, Ivone Ferreira; CASAROTTO, Raquel Aparecida; SAMELLI, Alessandra Giannella
    ABSTRACT Objective: to verify the effect of a vestibular rehabilitation program on workers with dizziness from the Division of Nutrition and Dietetics at a University Hospital. Methods: a total of 13 employees between 42 and 65 years of age participated, of whom, 1 was male, and 12, females. They were evaluated before and after the vestibular rehabilitation program using the Dizziness Handicap Inventory, Work Ability Index and Visual Analog Scale. The program was conducted in groups at the workplace. Statistical analysis was performed using the analysis of variance test for paired factors and the chi-square test. Results: in the pre- and post-vestibular rehabilitation comparison, significant differences were found in the Dizziness Handicap Inventory and Visual Analogue Scale scores. In the qualitative analysis of the Work Ability Index, an increase was observed in the number of workers who considered their ability to work to have improved. Conclusion: vestibular rehabilitation conducted in groups and in the working environment was effective in improving dizziness complaint in workers at the Division of Nutrition and Dietetics. It is believed that the positive experience of this program may be extended to other areas.
  • article 6 Citação(ões) na Scopus
    Avaliação do protetor auditivo em situação real de trabalho pelo método field Microphone-in-real-ear
    (2016) ROCHA, Clayton Henrique; LONGO, Isadora Altero; MOREIRA, Renata Rodrigues; SAMELLI, Alessandra Giannella
    ABSTRACT Purpose To evaluate the effectiveness of the attenuation of a hearing protector (HP) in a real work situation using the field-microphone-in-real-ear method (f-MIRE). Methods Eighteen individuals of both genders (mean age of 47.17±8 years) participated in this study. In the workplace, the personal attenuation level of the HP was assessed using the f-MIRE method, followed by orientation about the importance of using the HP, cleaning and storing the device, and training for effective placement. Results The analyses showed a significant statistic attenuation for all of the collected data (total noise, by frequency band and dose) when the noise levels in the lapel microphone and the probe microphone were compared. In the comparison of the attenuation values provided by the manufacturer and those found in this study, we observed higher values for the manufacturer in all frequency bands. No difference was observed for the noise levels in the different activities and times evaluated. Conclusion The findings of this study enabled us to know the personal level of attenuation of the HP during a real work situation, which was within the limits of tolerance. It was also possible to collect information about the environmental noise to which these workers are exposed. We noticed situations where this level exceeded the safety values, and therefore it is recommended the use of the HP. It is important that more studies are conducted using the f-MIRE method, because it may be an ally to assess the effectiveness of the HP attenuation in the workplace.