Agora exibindo 1 - 10 de 108
  • article 11 Citação(ões) na Scopus
    Extreme bariatric endoscopy: stenting to reconnect the pouch to the gastrojejunostomy after a Roux-en-Y gastric bypass
    (2012) MOURA, Eduardo G. H. de; GALVAO-NETO, Manoel P.; RAMOS, Almino C.; MOURA, Eduardo T. H. de; GALVAO, Thales D.; MOURA, Diogo T. H. de; FERREIRA, Flavio C.
    Among the possible complications of bariatric surgery, fistula and partial dehiscence of the gastric suture are well known. Reoperation often is required but results in significant morbidity. Endoscopic treatment of some bariatric complications is feasible and efficient. A modified metallic stent was placed between the gastroaesophageal junction and the alimentary jejunal limb, allowing the passage of a nasoenteric feeding tube into the jejunal limb. Endoscopy showed disruption of nearly the entire staple line at the gastric pouch. The modified stent was placed and allowed wound healing. After 31 days, the stent had migrated and was removed endoscopically. Total clousure of the fistula was reported 30 days afterward. Endoscopic treatment of some bariatric surgery complications is feasible and has been reported previously. This report presents a case of a serious leakage treated by placement of a self-expandable metal stent to bridge the fistula.
  • article
    Endoscopic polymer injection and endoluminal plication in treatment of gastroesophageal reflux disease: evaluation of long-term results
    (2018) MOURA, Eduardo Guimaraes Hourneaux De; SAIIUM, Rubens A. A.; NASI, Ary; CORONEL, Martin; MOURA, Diogo Turiani Hourneaux De; MOURA, Eduardo Turiani Hourneaux De; MINATA, Mauricio Kazuyoshi; CURY, Marcelo; FALCAO, Angela; CECCONELLO, Ivan; SAKAI, Paulo
    Background and study aims Us of proton pump inhibitors (PPIs) has made endoscopic treatment of gastroesophageal reflux disease (GERD) more efficient, with reduction in morbidity and complications. However, some patients persist with symptoms despite medical treatment and some are not compliant with it or cannot afford it for financial reasons, and thus they require non-pharmacological therapeutic options such as surgical fundoplication. Surgery may be effective in the short term, but there is related morbidity and concern about its long-term efficacy. The possibility of minimally invasive endoluminal surgeries has resulted in interest in and development of newly endoscopic devices. Good short-term results with surgical fundoplication lack of studies of is with long follow-up justify our interest in this study. The aim of this study was to investigate the efficacy of endoscopic polymer injection and endoluminal full-thickness plication in the long-term control of GERD. Patients and methods Forty-seven patients with GERD who underwent an endoscopic procedure were followed up for 60 months and evaluated for total response (RT), partial response (RP) and no response (SR) to endoscopic treatment with reintroduction of PPIs. Results Twenty-one patients received polymer injection (G0) and 26 endoluminal plication (G1). The number of patients with no response to endoscopic treatment with reintroduction of PPIs increased in time for both techniques (G0 P = 0.006; G1 P < 0.001). There was symptomatic improvement up to 12 months, with progressive loss of this trending up to 60 months in G0 and G1 (P < 0.001). Health-related quality of life score (GERD-HRQL) demonstrated TR in G0 and G1 at 1, 3, 6 and 12 months. The 60-month analysis showed an increased number of patients with SR in both groups. The quality of life assessment (SF-36) showed benefit in G0 up to 3 months. G0 showed a higher rate of complications. There were no deaths. There was healing of esophagitis at 3 months in 45 % of patients in G0 and 40 % in G1. There was no improvement in manometric or pH findings. Conclusion Endoscopic therapies were ineffective in controlling GERD in the long term.
  • article 1 Citação(ões) na Scopus
    USEFULNESS OF GASTRIC SUBMUCOSAL DISSECTION DEPTH TO EVALUATE SKILL ACQUIREMENT IN SHORT TERM TRAINING COURSES IN ESD: AN EXPERIMENTAL STUDY
    (2018) YAMAZAKI, Kendi; MOURA, Eduardo Guimarães Hourneaux de; VERAS, Mariana Matera; MESTIERI, Luiz Henrique; SAKAI, Paulo
    ABSTRACT BACKGROUND: Endoscopic submucosal dissection (ESD) is a complex endoscopic procedure, with high rates of adverse events and technical difficulties. To overcome that problem, many training centers published the importance of animal models for skill acquirement in ESD. However, no study has used the submucosal dissection depth (DSUB) as a parameter to evaluate the learning curve in ESD, which might be a relevant factor since an optimal resection plane is important to achieve a curative resection and avoid intraoperative complications. OBJECTIVE: This study aimed to assess ESD skill acquirement after short-term training sessions by evaluating the submucosal dissection depth (DSUB) and the association with adverse events. METHODS: This experimental study included 25 experienced endoscopists in therapeuthic procedures (>5years) and 75 specimens resected by ESD (three resections / endoscopist). Learning parameters (resection time, size, en bloc resection rate, bleeding, perforation and submucosal dissection depth) were prospectively evaluated. The percentages of DSUB of all specimens resected were calculated. RESULTS: All specimens were resected from the gastric body (n=75). The mean size of the resected specimens was 23.97±7.2 mm. The number of adverse events, including bleeding, perforation, and death, were 17 (22.67%), 3 (4%), and 0 cases, respectively. The average mean time by the third dissection decreased from 28.44±9.73 to 18.72±8.81 min (P<0.001). The proportion of DSUB in the bleeding and non-bleeding group were respectively 37.97%±21.13% and 68.66%±23.99%, indicating a significant association between DSUB and bleeding incidence (P<0.001). The ROC curve analysis indicated a cut-off point of 61% (sensitivity, 64%; specificity, 94%) of submucosal dissection depth associated with bleeding. Therefore, when ESD was performed at a depth of >61% of the submucosal layer, the risk for bleeding during the procedure decreased (PPV, 0.97; 95% CI, 0.85-0.99). CONCLUSION: Improvement in the learning curve in ESD and a better cognitive ability were seen by the third dissection in these short term training courses. And a significant association between DSUB and the risk of bleeding.
  • article 105 Citação(ões) na Scopus
    Metabolic Improvements in Obese Type 2 Diabetes Subjects Implanted for 1 Year with an Endoscopically Deployed Duodenal-Jejunal Bypass Liner
    (2012) MOURA, Eduardo G. H. de; MARTINS, Bruno C.; LOPES, Guilherme S.; ORSO, Ivan R.; OLIVEIRA, Suzana L. de; GALVAO NETO, Manoel P.; SANTO, Marco A.; SAKAI, Paulo; RAMOS, Almino C.; GARRIDO JUNIOR, Arthur B.; MANCINI, Marcio C.; HALPERN, Alfredo; CECCONELLO, Ivan
    Background: The purpose of this study was to evaluate the effect of the duodenal-jejunal bypass liner (DJBL), a 60-cm, impermeable fluoropolymer liner anchored in the duodenum to create a duodenal-jejunal bypass, on metabolic parameters in obese subjects with type 2 diabetes. Methods: Twenty-two subjects (mean age, 46.2 +/- 10.5 years) with type 2 diabetes and a body mass index between 40 and 60 kg/m(2) (mean body mass index, 44.8 +/- 7.4 kg/m(2)) were enrolled in this 52-week, prospective, open-label clinical trial. Endoscopic device implantation was performed with the patient under general anesthesia, and the subjects were examined periodically during the next 52 weeks. Primary end points included changes in fasting blood glucose and insulin levels and changes in hemoglobin A1c (HbA1c). The DJBL was removed endoscopically at the end of the study. Results: Thirteen subjects completed the 52-week study, and the mean duration of the implant period for all subjects was 41.9 +/- 3.2 weeks. Reasons for early removal of the device included device migration (n = 3), gastrointestinal bleeding (n = 1), abdominal pain (n = 2), principal investigator request (n = 2), and discovery of an unrelated malignancy (n = 1). Using last observation carried forward, statistically significant reductions in fasting blood glucose (-30.3 +/- 10.2 mg/dL), fasting insulin (-7.3 +/- 2.6 mu U/mL), and HbA1c (-2.1 +/- 0.3%) were observed. At the end of the study, 16 of the 22 subjects had an HbA1c < 7% compared with only one of 22 at baseline. Upper abdominal pain (n = 11), back pain (n = 5), nausea (n = 7), and vomiting (n = 7) were the most common device-related adverse events. Conclusions: The DJBL improves glycemic status in obese subjects with diabetes and therefore represents a nonsurgical, reversible alternative to bariatric surgery.
  • article 2 Citação(ões) na Scopus
    Potential premalignant status of gastric portion excluded after Roux en-Y gastric bypass in obese women: A pilot study
    (2019) RAVACCI, Graziela Rosa; ISHIDA, Robson; TORRINHAS, Raquel Suzana; SALA, Priscila; MACHADO, Natasha Mendonca; FONSECA, Danielle Cristina; CANUTO, Gisele Andre Baptista; PINTO, Ernani; NASCIMENTO, Viviane; TAVARES, Marina Franco Maggi; SAKAI, Paulo; FAINTUCH, Joel; SANTO, Marco Aurelio; MOURA, Eduardo Guimaraes Hourneaux; ARTIGIANI NETO, Ricardo; LOGULLO, Angela Flavia; WAITZBERG, Dan Linetzky
    We evaluated whether the excluded stomach (ES) after Roux-en-Y gastric bypass (RYGB) can represent a premalignant environment. Twenty obese women were prospectively submitted to double-balloon enteroscopy (DBE) with gastric juice and biopsy collection, before and 3 months after RYGB. We then evaluated morphological and molecular changes by combining endoscopic and histopathological analyses with an integrated untargeted metabolomics and transcriptomics multiplatform. Preoperatively, 16 women already presented with gastric histopathological alterations and an increased pH (>= 4.0). These gastric abnormalities worsened after RYGB. A 90-fold increase in the concentration of bile acids was found in ES fluid, which also contained other metabolites commonly found in the intestinal environment, urine, and faeces. In addition, 135 genes were differentially expressed in ES tissue. Combined analysis of metabolic and gene expression data suggested that RYGB promoted activation of biological processes involved in local inflammation, bacteria overgrowth, and cell proliferation sustained by genes involved in carcinogenesis. Accumulated fluid in the ES appears to behave as a potential premalignant environment due to worsening inflammation and changing gene expression patterns that are favorable to the development of cancer. Considering that ES may remain for the rest of the patient's life, long-term ES monitoring is therefore recommended for patients undergoing RYGB.
  • article 5 Citação(ões) na Scopus
    EFFICACY OF ENDOSCOPIC TOPICAL MITOMYCIN C APPLICATION IN CAUSTIC ESOPHAGEAL STRICTURES IN THE PEDIATRIC POPULATION: A SYSTEMATIC REVIEW AND META-ANALYSIS OF RANDOMIZED CONTROLLED TRIALS
    (2021) FLOR, Marcelo Mochate; RIBEIRO, Igor Braga; DE MOURA, Diogo Turiani Hourneaux; MARQUES, Sérgio Barbosa; BERNARDO, Wanderley Marques; DE MOURA, Eduardo Guimarães Hourneaux
    ABSTRACT BACKGROUND: Caustic ingestion and development of esophageal strictures are recognized major public health problems in childhood. Different therapeutic methods have been proposed in the management of such strictures. OBJECTIVE: To evaluate efficacy and risk of endoscopic topical application of mitomycin C in the treatment of caustic esophageal strictures. METHODS: We searched MEDLINE, EMBASE, Central Cochrane, and LILACS databases. The outcomes evaluated were dysphagia resolution rate, number of dilations performed in resolved cases, and the number of dilations performed in all patients. RESULTS: Three randomized clinical trials were included for final analysis with a total of 190 patients. Topical mitomycin C application group showed a significant increase in dysphagia resolution rate, corresponding to a 42% higher dysphagia resolution as compared to endoscopic dilation alone, with statistical significance between the two groups (RD: 0.42 - [CI: 0.29-0.56]; P-value <0.00001). The mean number of dilations performed in resolved cases were significantly less in the topical mitomycin C application group, compared to endoscopic dilations alone, with statistical significance between the two groups (MD: 2.84 [CI: 1.98-3.69]; P-value <0.00001). When comparing the number of dilations in all patients, there was no statistical difference between the two groups (MD: 1.46 [CI: -1.53-4.44]; P-value =0.34). CONCLUSION: Application of topical mitomycin C with endoscopic dilations in caustic esophageal strictures was more effective in dysphagia resolution than endoscopic therapy alone in the pediatric population. Moreover, topical mitomycin C application also reduced the number of dilation sessions needed to alleviate dysphagia without rising morbidity.
  • article
    Long-term follow-up after transoral outlet reduction following Roux-en-Y gastric bypass: Back to stage 0?
    (2023) BRUNALDI, Vitor Ottoboni; OLIVEIRA, Guilherme Henrique Peixoto de; KERBAGE, Anthony; RIBAS, Pedro Henrique; NUNES, Felipe; FARIA, Galileu; MOURA, Diogo de; RICCIOPPO, Daniel; SANTO, Marco; MOURA, Eduardo de
    Background and study aims Significant weight regain affects up to one-third of patients after Roux-en-Y gastric bypass (RYGB) and demands treatment. Transoral outlet reduction (TORe) with argon plasma coagulation (APC) alone or APC plus full-thickness suturing TORe (APC-FTS) is effective in the short term. However, no study has investigated the course of gastrojejunostomy (GJ) or quality of life (QOL) data after the first post-procedure year.Patients and methods Patients eligible for a 36-month follow-up visit after TORe underwent upper gastrointestinal endoscopy with measurement of the GJ and answered QOL questionnaires (RAND-36). The primary aim was to evaluate the long-term outcomes of TORe, including weight loss, QOL, and GJ anastomosis (GJA) size. Comparisons between APC and APC-FTS TORe were a secondary aim.Results Among 39 eligible patients, 29 returned for the 3-year follow-up visit. There were no significant differences in demographics between APC and APC-FTS TORe groups. At 3 years, patients from both groups regained all the weight lost at 12 months, and the GJ diameter was similar to the pre-procedure assessment. As to QOL, most improvements seen at 12 months were lost at 3 years, returning to pre-procedure levels. Only the energy/fatigue domain improvement was kept between the 1- and 3-year visits.Conclusions Obesity is a chronic relapsing disease. Most effects of TORe are lost at 3 years, and redilation of the GJA occurs. Therefore, TORe should be considered iterative rather than a one-off procedure.
  • article 1 Citação(ões) na Scopus
    Endoscopic Management of Anchor Erosion Adjacent to the Pylorus Following Duodenal-Jejunal Bypass Sleeve
    (2019) MOURA, Eduardo Guimaraes Hourneaux De; MOURA, Diogo Turiani Hourneaux de; GALVAO-NETO, Manoel; SAKAI, Christiano Makoto; SILVA, Gustavo Luis Rodela; BAZARBASHI, Ahmad Najdat; THOMPSON, Christopher C.
    Introduction Obesity is a pandemic associated with significant comorbidities such as type 2 diabetes (T2DM). RYGB is an effective treatment modality for obesity and T2DM. However, bariatric surgery is currently limited to a relatively small population of patients. The duodenal-jejunal bypass sleeve (DJBS) has recently emerged as a promising therapy for obesity and T2DM by providing similar physiological effects to RYGB. We describe a case of a patient with a previously placed DJBS presenting with abdominal pain from anchor erosion managed with an endoscopic approach. Methods A 58-year-old man with obesity and T2DM who had failed prior medical therapy for obesity was referred for DJBS placement. This was placed without complications. At 8 weeks follow-up, he developed abdominal pain and vomiting prompting immediate endoscopic evaluation. Results EGD revealed an anchor erosion resulting in mild stenosis of the pylorus. Additionally, hyperplastic tissue was found to be adhered to the device in the duodenal bulb. Endoscopic removal with balloon dilation was unsuccessful, and a stent was placed in a ""stent-in-stent"" fashion through the sleeve to compress the area of tissue ingrowth encouraging local tissue necrosis and device extraction. At 15 days follow-up, the stent was removed; however, the DJBS remained adhered and immobile. Next, the ingrowing hyperplastic tissue was resected in a piecemeal fashion. This resulted in mobilization of the sleeve anchors in the duodenal bulb and successful removal of the DJBS. Conclusions DJBS endoscopic removal is safe and effective even in challenging cases, thus preventing the need for surgical intervention.
  • article 13 Citação(ões) na Scopus
    INITIAL EXPERIENCE OF ENDOSCOPIC SUBMUCOSAL DISSECTION IN BRAZIL TO TREAT EARLY GASTRIC AND ESOPHAGHEAL CANCER: a multi-institutional analysis
    (2013) CHAVES, Dalton Marques; MOURA, Eduardo Guimaraes H.; MILHOMEM, Daniela; ARANTES, Vitor N.; YAMAZAKI, Kendi; MALUF, Fauze; ALBUQUERQUE, Walton; CONRADO, Antonio Carlos C.; ARAUJO, Julia C.; UEJO, Paula H. S.; SAKAI, Paulo
    Objective This study aimed to evaluate the feasibility and clinicopathological characteristics of early gastric and esophageal cancers treated with endoscopic submucosal dissection (ESD) at five centers in Brazil. Methods Five centers in Brazil reported their initial experience with ESD. The cases reported had already been collected by each center before pooled analysis. Results Were resected 62 gastric lesions; 52(83,8%) of the gastric lesions were well-differentiated adenocarcinoma, 31(50%) from the antrum, 24 (38.7%) type IIa. 51 (82.2%) lesions had en-block resection with three showing lateral margin compromise. Concerning invasion, 25 (40.3%) tumors were M1. Mean tumor diameter was 18.9 mm (range, 0.6-5.0 cm) and mean procedure duration was 119.45 minutes. Gastric perforation occurred in three (4.8%) patients. Mean follow-up duration was 11.3 months, with two local recurrences and one death from pneumonia Seven months after treatment. Of the 16 esophageal lesions resected, 14 (87.4%) were squamous cell carcinoma, 10 (62.5%) were located proximally and 8 (50.0%) type IIa. Mean tumor diameter was 23.8 mm (range, 6-60 mm). Thirteen (81.2%) lesions had en-block resection with five cases of lateral margin compromise. Eight (50.0%) lesions were M1. Mean procedure duration was 78 minutes (range, 20-150 min). Complications included pneumomediastinum in two (12.5%) patients and stenosis in one (6.2%). Mean duration of follow-up was 8.6 months, with no local recurrence despite the presence of lateral margin compromise. Conclusion Different centers in Brazil feasibly perform ESD with a high success rate.
  • article 1 Citação(ões) na Scopus
    Pure Cut or Endocut for Biliary Sphincterotomy? A Multicenter Randomized Clinical Trial
    (2023) FUNARI, Mateus Pereira; BRUNALDI, Vitor Ottoboni; PROENCA, Igor Mendonca; GOMES, Pedro Victor Aniz; QUEIROZ, Lucas Tobias Almeida; VIEIRA, Yuri Zamban; MATUGUMA, Sergio Eiji; IDE, Edson; FRANZINI, Tomazo Antonio Prince; SANTOS, Marcos Eduardo Lera dos; CHENG, Spencer; MINATA, Mauricio Kazuyoshi; SANTOS, Jose Sebastio dos; MOURA, Diogo Turiani Hourneaux de; KEMP, Rafael; MOURA, Eduardo Guimares Hourneaux de
    INTRODUCTION: Adverse events (AE) after endoscopic retrograde cholangiopancreatography (ERCP) are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger PEP or bleeding. Therefore, this study evaluated the outcomes of 2 electric current modes used during biliary sphincterotomy. METHODS: From October 2019 to August 2021, consecutive patients with native papilla undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation. RESULTS: A total of 550 patients were randomized (272 pure cut and 278 endocut). The overall PEP rate was 4.0% and significantly higher in the endocut group (5.8% vs 2.2%, P = 0.034). Univariate analysis revealed >5 attempts (P = 0.004) and endocut mode (P = 0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (P = 0.005) and a trend for endocut mode as risk factors for PEP (P = 0.052). Intraprocedural bleeding occurred more often with pure cut (P = 0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with endocut (P = 0.047). There was no difference in perforation (P = 1.0) or infection (P = 0.4999) between the groups. DISCUSSION: Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCT assessing the impact of electric current on AE with overlapping preventive measures such as rectal nonsteroidal anti-inflammatory drugs and hyperhydration are needed. The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.