Por favor, use este identificador para citar o enlazar este ítem: https://observatorio.fm.usp.br/handle/OPI/30225
Título: Determinants of success and hemodynamic impact of balloon postdilatation of self-expanding transcatheter aortic valves
Autor: ABDELGHANI, MohammadWINTER, Robbert J. deMIYAZAKI, YosukeMODOLO, RodrigoTATEISHI, HirokiCAVALCANTE, RafaelSARMENTO-LEITE, RogerioMANGIONE, Jose A.ABIZAID, AlexandreSOLIMAN, Osama I. I.ONUMA, YoshinobuLEMOS, Pedro A.SERRUYS, Patrick W.BRITO JR., Fabio S. de
Citación: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, v.92, n.5, p.945-953, 2018
Resumen: Objectives To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) Background BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. Methods Patients (n = 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD (<= mild PVL + BPD) and Failed BPD (moderate-severe PVL + BPD). Results BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter <= 0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P = .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P = .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). Conclusion BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.
Aparece en las colecciones:

Artigos e Materiais de Revistas Científicas - HC/InCor
Instituto do Coração - HC/InCor

Artigos e Materiais de Revistas Científicas - LIM/11
LIM/11 - Laboratório de Cirurgia Cardiovascular e Fisiopatologia da Circulação


Ficheros en este ítem:
Fichero Descripción TamañoFormato 
art_ABDELGHANI_Determinants_of_success_and_hemodynamic_impact_of_balloon_2018.PDF
  Restricted Access
publishedVersion (English)333.58 kBAdobe PDFVisualizar/Abrir Request a copy

Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.